An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()A、Processor failureB、Third party memoryC、Disk drive failureD、ESD during the upgradeE、Backplane failure
An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()
- A、Processor failure
- B、Third party memory
- C、Disk drive failure
- D、ESD during the upgrade
- E、Backplane failure
相关考题:
An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()A. Processor failureB. Third party memoryC. Disk drive failureD. ESD during the upgradeE. Backplane failure
While troubleshooting a video problem on an application server, the system administrator has determined that the video firmware should be updated. Which of the following sources should be used to locate an appropriate update for this hardware?()A. Third-party manufacturerB. Video chipset manufacturerC. Server manufacturerD. Operating system manufacturerE. Shareware file sharing site
An administrator is troubleshooting a problem on an application server, but has not determined the cause of the problem and is not able to replicate the problem. Which of the following should the administrator do prior to escalating the issue?()A、Gather information from users.B、Reboot the server.C、Apply the latest service packs to the operating system.D、Perform a root cause analysis
An administrator identifies that a server is shutting down. The administrator powers up the server and OS loads but after a few minutes it powers down again. Which of the following is the cause?()A、Redundant power supply failureB、CPU overheatingC、Memory failureD、Hard disk failure
An administrator is receiving too many alerts for processor utilization on a server. Which of the following should the administrator perform?()A、Add more cache.B、Configure RAID 5.C、Install an additional NIC for teaming.D、Adjust SNMP thresholds.
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()A、MemoryB、SCSI backplaneC、SCSI drivesD、Motherboard
An administrator attempts to install the latest security patches for an older server. When the administrator runs the patch installer, the install fails. The administrator tries again, and the installer fails again. Which of the following is the MOST likely reason for this?()A、The administrator improperly configured the virtual memory settings on the server.B、The administrator is using incorrect patch switches for the install.C、The administrator is trying to install security patches for software that is not installed.D、The administrator is trying to install patches that require hard drive encryption on the server.
While troubleshooting a video problem on an application server, the system administrator has determined that the video firmware should be updated. Which of the following sources should be used to locate an appropriate update for this hardware?()A、Third-party manufacturerB、Video chipset manufacturerC、Server manufacturerD、Operating system manufacturerE、Shareware file sharing site
An administrator has encountered a problem with a particular piece of software installed on the server and begins the troubleshooting process. Which of the following is the FIRST place the administrator should look for specific information about the problem?()A、The supporting documentationB、The vendor websiteC、The InternetD、The server event logs
An administrator is upgrading memory on the server. Once the server in turned back on, the administrator notices that the memory has not changed. The system board website says the board should accept the new amount of memory. Which of the following should the administrator do FIRST?()A、 Replace memory chips with known good memory chips.B、 Reseat the memory chips.C、 Update the BIOS.D、 Upgrade the server OS.
After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()A、 The power supply is not sufficient to power the server.B、 The voltage regulator module (VRM) was not installed.C、 The IRQ setting was not set.D、 The DMA setting was not set.
The administrator has just installed a new memory module into the server. Now, the server is not showing the new memory. Which of the following should the administrator perform FIRST?()A、System rebootB、Reseat the memoryC、Install the latest firmwareD、Install the latest driver
An administrator is troubleshooting a problem on an application server, but has not determined the cause of the problem and is not able to replicate the problem. Which of the following should the administrator do prior to escalating the issue?()A、 Gather information from users.B、 Reboot the server.C、 Apply the latest service packs to the operating system.D、 Perform a root cause analysis.
An administrator is troubleshooting issues on an application server.After a root cause analysis,the administrator has determined that there were some unauthorized logins to the server.Which of the following locations would BEST help to determine details about the unauthorized logins?()A、Active DirectoryB、DHCP logsC、Security logsD、System logs
When troubleshooting hardware issues with a server, which of the following is MOST likely to cause a problem in receiving vendor support?()A、 Third party cablesB、 Third party memoryC、 Signed driversD、 Server type
An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array.When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()A、 Restart the installation via WDS.B、 Shut down the server and check that all RAID drives are connected properly.C、 Restart the installation from CD and press F6 to install RAID drivers.D、 Go into the BIOS and set all RAID drives to compatibility mode.
A system administrator received the following message while trying to ssh to a server: connection timed out.The administrator pinged the server and had no response. The administrator then pinged the gateway, and was successful. Which tool could the administrator use next to isolate the problem?()A、routeB、tracerouteC、netstat -nrD、broadcast ping
单选题An administrator attempts to install the latest security patches for an older server. When the administrator runs the patch installer, the install fails. The administrator tries again, and the installer fails again. Which of the following is the MOST likely reason for this?()A The administrator improperly configured the virtual memory settings on the server.B The administrator is using incorrect patch switches for the install.C The administrator is trying to install security patches for software that is not installed.D The administrator is trying to install patches that require hard drive encryption on the server.
单选题An administrator is upgrading memory on the server. Once the server in turned back on, the administrator notices that the memory has not changed. The system board website says the board should accept the new amount of memory. Which of the following should the administrator do FIRST?()A Replace memory chips with known good memory chips.B Reseat the memory chips.C Update the BIOS.D Upgrade the server OS.
多选题An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()AProcessor failureBThird party memoryCDisk drive failureDESD during the upgradeEBackplane failure
单选题An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array.When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()A Restart the installation via WDS.B Shut down the server and check that all RAID drives are connected properly.C Restart the installation from CD and press F6 to install RAID drivers.D Go into the BIOS and set all RAID drives to compatibility mode.
单选题After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()A The power supply is not sufficient to power the server.B The voltage regulator module (VRM) was not installed.C The IRQ setting was not set.D The DMA setting was not set.
单选题The administrator has just installed a new memory module into the server. Now, the server is not showing the new memory. Which of the following should the administrator perform FIRST?()ASystem rebootBReseat the memoryCInstall the latest firmwareDInstall the latest driver
单选题An administrator is troubleshooting a problem on an application server, but has not determined the cause of the problem and is not able to replicate the problem. Which of the following should the administrator do prior to escalating the issue?()A Gather information from users.B Reboot the server.C Apply the latest service packs to the operating system.D Perform a root cause analysis.
单选题An administrator identifies that a server is shutting down. The administrator powers up the server and OS loads but after a few minutes it powers down again. Which of the following is the cause?()A Redundant power supply failureB CPU overheatingC Memory failureD Hard disk failure
单选题An administrator identifies that a server is shutting down. The administrator powers up the server and OS loads but after a few minutes it powers down again. Which of the following is the cause?()ARedundant power supply failureBCPU overheatingCMemory failureDHard disk failure
单选题When troubleshooting hardware issues with a server, which of the following is MOST likely to cause a problem in receiving vendor support?()A Third party cablesB Third party memoryC Signed driversD Server type