A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()A、MemoryB、SCSI backplaneC、SCSI drivesD、Motherboard
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()
- A、Memory
- B、SCSI backplane
- C、SCSI drives
- D、Motherboard
相关考题:
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status?() A. Break mirror arrayB. Replace cache batteryC. Replace hot standbyD. Restore from back upE. Replace defective hard drives
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()A. MemoryB. SCSI backplaneC. SCSI drivesD. Motherboard
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array.How much usable disk space will this array have?()A.288GBB.360GBC.432GBD.728GB
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system’s administrator has decided to mirror two drives for the operating system. Which of the following is the maximum space the administrator will have remaining to use for data when using RAID 0?()A、292GBB、438GBC、584GBD、728GB
An administrator is building a server that will run a data warehousing application.The server was ordered with eight 300GB drives.The application requires a dedicated storage location for the OS and one for critical files.The critical file storage needs fast access but must provide high redundancy.The OS requires 100GB and the file requires 950GB.Which of the following configurations will BEST suit the data warehouse needs?()A、OS:3 Drives,RAID 1 with hot spare;Files:5 Drives,RAID 5 with hot spareB、OS:2 Drives,RAID 1;Files:6 Drives,RAID 1C、OS:2 Drives,RAID 0;Files:6 Drives,RAID 5D、OS:2 Drives,RAID 1;Files:6 Drives,RAID 5 with hot spare
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()A、 288GBB、 360GBC、 432GBD、 728GB
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status?()A、Break mirror arrayB、Replace cache batteryC、Replace hot standbyD、Restore from back upE、Replace defective hard drives
An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array. When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()A、Restart the installation via WDS.B、Shut down the server and check that all RAID drives are connected properly.C、Restart the installation from CD and press F6 to install RAID drivers.D、Go into the BIOS and set all RAID drives to compatibility mode
An administrator setting up software RAID 1 on a Windows Server with two volumes for twoseparate hard drives, but the option for mirrored is grayed out. Which of the following is the MOST likely reason why this is occurring?()A、The disks have been setup as basic.B、The page file must be at least 4GB to support mirrored drives.C、The disks have been setup as dynamic.D、Windows does not support software RAID 1.
A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()A、Replace the driveB、Restore the drive from backupC、Reboot the serverD、Reconfigure RAID 5 to RAID 10
Which of the following offers the MOST redundancy for a system but is also very costly? ()A、 RAID implementationB、 Disk-to-disk replicationC、 Server-to-server clusteringD、 Hot site replication
A server crashed because it ran out of all free available disk space. After booting the server backup it is noticed that enhanced logging was enabled on the web server software months before. Which of the following is MOST likely causing the disk to run out of space? ()A、 The web server requires larger disk drives.B、 Traffic to the web server has increased.C、 Disks are not large enough for the web server software.D、 Log files are filling the disk.
An administrator installs a new server with five 146GB drives and implements RAID 5 for hardware redundancy.How much disk space will be available for the OS, tools and regular files?()A、146GBB、438GBC、584GBD、730GB
A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status? ()A、 Break mirror arrayB、 Replace cache batteryC、 Replace hot standbyD、 Restore from backupE、 Replace defective hard drives
A new array of hard drives has been added to an existing server; however, when the server is booted into the Windows OS the new drives fail to appear in My Computer. From which of the following locations can the new storage drives be added?()A、 Format commandB、 HypervisorC、 Computer ManagementD、 Disk ManagementE、 Virtual Center
A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()A、288GBB、360GBC、432GBD、728GB
A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline. Which of the following components would MOST likely have caused the problem?()A、 MemoryB、 SCSI backplaneC、 SCSI drivesD、 Motherboard
An xSeries specialist monitors a customer’s server that has poor performance. The customer is running an x365 with a ServeRAID 6i controller with write-back cache turned on and ten 15K rpm drives in a RAID-5 array. It is a mission-critical server and must have a redundant storage system. Performance tests indicate that the Average Disk sec/Transfer exceeds 20 ms. Which of the following is the lowest-cost method to increase the throughput?()A、Disable the ServRAID cacheB、Change the RAID level to 10C、Change the cache level to Write ThroughD、Add five more drives to the array to increase the number of read/write heads
A customer has a need for an xSeries server for an application requiring 12GB memory with the capacity of up to 20GB. The HDD configuration needs to be as follows: (1)Two drives RAID-1 for the operating system (2)Five drives for Data in a RAID-5 configuration with one Hot-Spare (3)All drives have to be internal. Which of the following will satisfy the requirements for the application?()A、x366B、x255C、x346D、x455
单选题A customer has a need for an xSeries server for an application requiring 12GB memory with the capacity of up to 20GB. The HDD configuration needs to be as follows: (1)Two drives RAID-1 for the operating system (2)Five drives for Data in a RAID-5 configuration with one Hot-Spare (3)All drives have to be internal. Which of the following will satisfy the requirements for the application?()Ax366Bx255Cx346Dx455
单选题Which of the following offers the MOST redundancy for a system but is also very costly? ()A RAID implementationB Disk-to-disk replicationC Server-to-server clusteringD Hot site replication
单选题An administrator is building a server that will run a data warehousing application.The server was ordered with eight 300GB drives.The application requires a dedicated storage location for the OS and one for critical files.The critical file storage needs fast access but must provide high redundancy.The OS requires 100GB and the file requires 950GB.Which of the following configurations will BEST suit the data warehouse needs?()AOS:3 Drives,RAID 1 with hot spare;Files:5 Drives,RAID 5 with hot spareBOS:2 Drives,RAID 1;Files:6 Drives,RAID 1COS:2 Drives,RAID 0;Files:6 Drives,RAID 5DOS:2 Drives,RAID 1;Files:6 Drives,RAID 5 with hot spare
单选题A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline.Which of the following components would MOST likely have caused the problem?()AMemoryBSCSI backplaneCSCSI drivesDMotherboard
多选题A server configured with RAID 5 has recently suffered from two simultaneous disk failures. Which of the following would be required to bring the server back to operational status? ()ABreak mirror arrayBReplace cache batteryCReplace hot standbyDRestore from backupEReplace defective hard drives
单选题A server has five hot pluggable SCSI disk drives in a RAID 5 array. The server OS crashed and the server will not boot. The administrator noticed that all of the disk drives have gone offline. Which of the following components would MOST likely have caused the problem?()A MemoryB SCSI backplaneC SCSI drivesD Motherboard
单选题A server crashed because it ran out of all free available disk space. After booting the server backup it is noticed that enhanced logging was enabled on the web server software months before. Which of the following is MOST likely causing the disk to run out of space? ()A The web server requires larger disk drives.B Traffic to the web server has increased.C Disks are not large enough for the web server software.D Log files are filling the disk.
单选题A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()A 288GBB 360GBC 432GBD 728GB