单选题A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()A Using ’diagmenu’ command, set fcs1 to Defined.B Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.C Using ’diagmenu’ command, set the fcs1 state to DefinedD Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined

单选题
A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()
A

 Using ’diagmenu’ command, set fcs1 to Defined.

B

 Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.

C

 Using ’diagmenu’ command, set the fcs1 state to Defined

D

 Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined


参考解析

解析: 暂无解析

相关考题:

A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced.Which command should an administrator use to remove the card device and attached child devices?() A.rmdev -Rdl fcs0B.rmdev -cdl fcs0C.rmdev -cdl fscsi0D.rmdev -Rdl fscsi0

A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A、One fibre channel switchB、Two fibre channel switchesC、Two Ethernet cardsD、Nothing

A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()A、 Using ’diagmenu’ command, set fcs1 to Defined.B、 Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.C、 Using ’diagmenu’ command, set the fcs1 state to DefinedD、 Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined

The staff is not able to access a database server.  The server has an ’Operating System not found’error and is set to boot from a fiber channel SAN. All other database servers are set to boot from the SAN and access the same switch and data as this database server. Which of the following is the MOST likely cause of the problem?()A、The SAN is offlineB、Fiber channel switchC、Multiple failed drives in the SAND、HBA

A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()A、Would 10/100 Ethernets work as well?B、Should there be eight fibre channel adapters?C、Should there be an async adapter for heartbeat?D、Will all LPARs need access to a common fibre channel tape drive?

A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()A、LPAR-A with 1Gb FC HBA and SAN connectionB、LPAR-B with 2Gb FC HBA and SAN connectionC、LPAR-C with 4Gb FC HBA and SAN connectionD、LPAR-D with 8Gb FC HBA and SAN connection

A cluster using IPAT via IP aliasing has four adapters. Normally there are several resource  groups that have a total of four service IP labels. When two of the adapters fail, what happens?()  A、 The resource group containing the IP labels changes to an "offline" state.B、 The IP service labels of the failed adapters relocate the surviving adapters.C、 Nothing because the resource groups wait for the adapters to become active again.D、 The resource groups containing the IP labels of the failed adapters migrate to a backup node.

A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced. Which command should an administrator use to remove the card device and attached child devices?()A、rmdev -Rdl fcs0B、rmdev -cdl fcs0C、rmdev -cdl fscsi0D、rmdev -Rdl fscsi0

Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()  A、 Disk heartbeatB、 Error notificationC、 Event notificationD、 Application monitor

A customer has a small SAN with both Linux and Windows servers attached to a DS4300 storage server through a redundant fabric. Which of the following is the most important consideration to ensure that this configuration would function properly?()A、The utilization of interswitch links between the redundant switchesB、The enablement of the multi-OS Storage Partitioning feature on the DS4300C、Selection of 50u multi-mode Fibre to ensure 2Gb operationD、The RAID level of the array on the DS4300 storage server

A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()   A、 an additional 1GB RAM to each node.B、 Another bootable mirrored disk drive.C、 A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.D、 Nothing,because this is a viable cluster solution with no single points of failure.

A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()A、Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solutionB、Add iSCSI cards to the servers and direct attach them to a DS300 dual controller modelC、Use clustered NAS solution with redundant gigabit network connectionsD、Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

A medium-sized company with 500 employees has a rapidly growing storage infrastructure with clustered mail, database, and file and print core business applications running on six servers.  Using current direct attached SCSI storage pools to each server leads to inefficient utilization of storage space.They also have a backup device attached to each server.  They want to consolidate their storage and backup infrastructure into a scalable, high availability and high performance solution.  The customer’s top priorities are performance, cost, and availability.   Which of the following backup solutions best satisfies the customer requirements?()A、A DS4000 SAN with flash copy enabled for volume mirroringB、An iSCSI solution with dedicated backup server with SCSI attached tape libraryC、A NAS solution with SCSI direct attached tape library with dedicated backup networkD、A DS4000 SAN with fibre channel attached tape library solution with dedicated backup zone

You are designing a Hyper-V solution. You plan to virtualize an application server. The application server requires failover clustering that uses shared storage. You need to choose the correct storage solution. What should you choose?()A、Two child partitions with volumes mounted from an iSCSI SANB、Two host servers with Fibre Channel-attached storage enabled for Cluster Shared Volumes (CSVs)C、Two host servers with iSCSI-attached storage enabled for Cluster Shared Volumes (CSVs)D、Two child partitions with VHDs stored on an iSCSI SAN

单选题A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()AWould 10/100 Ethernets work as well?BShould there be eight fibre channel adapters?CShould there be an async adapter for heartbeat?DWill all LPARs need access to a common fibre channel tape drive?

单选题A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()AOne fibre channel switchBTwo fibre channel switchesCTwo Ethernet cardsDNothing

单选题A system has two configured fibre channel cards, one of which, fsc0, has failed and must be replaced.  Which command should an administrator use to remove the card device and attached child devices?()Armdev -Rdl fcs0Brmdev -cdl fcs0Crmdev -cdl fscsi0Drmdev -Rdl fscsi0

单选题A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()ALPAR-A with 1Gb FC HBA and SAN connectionBLPAR-B with 2Gb FC HBA and SAN connectionCLPAR-C with 4Gb FC HBA and SAN connectionDLPAR-D with 8Gb FC HBA and SAN connection

单选题A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()A an additional 1GB RAM to each node.B Another bootable mirrored disk drive.C A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.D Nothing,because this is a viable cluster solution with no single points of failure.

单选题A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()A Using ’diagmenu’ command, set fcs1 to Defined.B Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.C Using ’diagmenu’ command, set the fcs1 state to DefinedD Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined

单选题A medium-sized company with 500 employees has a rapidly growing storage infrastructure with clustered mail, database, and file and print core business applications running on six servers.  Using current direct attached SCSI storage pools to each server leads to inefficient utilization of storage space.They also have a backup device attached to each server.  They want to consolidate their storage and backup infrastructure into a scalable, high availability and high performance solution.  The customer’s top priorities are performance, cost, and availability.   Which of the following backup solutions best satisfies the customer requirements?()AA DS4000 SAN with flash copy enabled for volume mirroringBAn iSCSI solution with dedicated backup server with SCSI attached tape libraryCA NAS solution with SCSI direct attached tape library with dedicated backup networkDA DS4000 SAN with fibre channel attached tape library solution with dedicated backup zone

单选题Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()A Disk heartbeatB Error notificationC Event notificationD Application monitor

单选题The staff is not able to access a database server.  The server has an ’Operating System not found’error and is set to boot from a fiber channel SAN. All other database servers are set to boot from the SAN and access the same switch and data as this database server. Which of the following is the MOST likely cause of the problem?()AThe SAN is offlineBFiber channel switchCMultiple failed drives in the SANDHBA

单选题A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()AMove the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsBMove the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.CMove the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.DMove the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

单选题A cluster using IPAT via IP aliasing has four adapters. Normally there are several resource  groups that have a total of four service IP labels. When two of the adapters fail, what happens?()A The resource group containing the IP labels changes to an offline state.B The IP service labels of the failed adapters relocate the surviving adapters.C Nothing because the resource groups wait for the adapters to become active again.D The resource groups containing the IP labels of the failed adapters migrate to a backup node.

单选题A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()AAdd redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solutionBAdd iSCSI cards to the servers and direct attach them to a DS300 dual controller modelCUse clustered NAS solution with redundant gigabit network connectionsDAdd redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

单选题A customer has a small SAN with both Linux and Windows servers attached to a DS4300 storage server through a redundant fabric. Which of the following is the most important consideration to ensure that this configuration would function properly?()AThe utilization of interswitch links between the redundant switchesBThe enablement of the multi-OS Storage Partitioning feature on the DS4300CSelection of 50u multi-mode Fibre to ensure 2Gb operationDThe RAID level of the array on the DS4300 storage server