单选题A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()AWould 10/100 Ethernets work as well?BShould there be eight fibre channel adapters?CShould there be an async adapter for heartbeat?DWill all LPARs need access to a common fibre channel tape drive?

单选题
A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()
A

Would 10/100 Ethernets work as well?

B

Should there be eight fibre channel adapters?

C

Should there be an async adapter for heartbeat?

D

Will all LPARs need access to a common fibre channel tape drive?


参考解析

解析: 暂无解析

相关考题:

Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()A、Create LVM mirrors between LUNsB、MPIO is necessary as the device driverC、Use separate fibre adapters in the Virtual IO Server for each LUND、Virtual IO Server is a disk subsystem and must control the LUNs behind it

A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem.  If fcs1 has failed, what is the correct procedure to rectify this problem? ()A、 Using ’diagmenu’ command, set fcs1 to Defined.B、 Using ’oem_setup_env’ and ’rmdev -R’ commands, set fcs1 adapter to ’Defined’ state.C、 Using ’diagmenu’ command, set the fcs1 state to DefinedD、 Using ’oem_setup_env’ and ’rmdev -dl’ commands, set the state of fcs1 to Defined

A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A、4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server B、Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module C、Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module D、Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()A、Would 10/100 Ethernets work as well?B、Should there be eight fibre channel adapters?C、Should there be an async adapter for heartbeat?D、Will all LPARs need access to a common fibre channel tape drive?

A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()A、LPAR-A with 1Gb FC HBA and SAN connectionB、LPAR-B with 2Gb FC HBA and SAN connectionC、LPAR-C with 4Gb FC HBA and SAN connectionD、LPAR-D with 8Gb FC HBA and SAN connection

A small organization is purchasing a POWER5 to consolidate four applications. Currently, each application has two Host Bus Adapters (HBA) connected to an Enterprise Storage Server (ESS). The customer is concerned about the cost of purchasing eight new HBAs. Which feature of virtualization will be most beneficial to this organization?()A、Virtual EthernetB、Micro-PartitioningC、Virtual I/O ServerD、Capped and uncapped partitions

Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()  A、 Disk heartbeatB、 Error notificationC、 Event notificationD、 Application monitor

A customer wants to boot from an iSCSI SAN with their IBM BladeCenter infrastructure running Microsoft Windows Server 2000.  What is required for the customer to be able to perform this?()A、Fibre Channel Expansion Card for each Blade ServerB、cKVM Card for each Blade ServerC、iSCSI Expansion Card for each Blade ServerD、4Gb Modular Flash Drive

A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A、Dual power supplies.B、Twice the amount of disk.C、Two dual-port LHEA adapters.D、Two dual-port fibre channel adapters.

A customer is ready to order a pSeries solution.  However, the pSeries technical specialist is unsure whether the customer preferred the fibre channel or the external SCSI disk attachment option.  What is the most appropriate action for the specialist to take next?()A、Ask the customer to confirm which option is best for their environment.B、Order the fibre channel option and purchase a converter later if necessary.C、Order both SCSI and fibre channel adapters to cover both potential options.D、Inform the customer that fibre channel was selected for performance reasons.

A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()   A、 an additional 1GB RAM to each node.B、 Another bootable mirrored disk drive.C、 A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.D、 Nothing,because this is a viable cluster solution with no single points of failure.

The customer currently has 20 servers with 1 TB of internal capacity on each server. The serverscommunicate over 10/100/1000 Ethernet. The customer would like to move to a shared storagesubsystem with Fibre Channel hard drives. Budget is a key issue for them. Which option wouldallow for the lowest cost to implement?()A、IBM DS8700 B、IBM N6040 C、IBM Storwize V7000 D、IBM XIV Storage System

A banking customer has the following requirements for an IBM BladeCenter solution with high speed fibre channel: (1)four 4-socket Microsoft SQL servers with two hot swap SAS drives  (2)two physical Microsoft Active Directory Servers  (3)twenty-two physical Citrix servers  (4)three physical Web servers (5)one physical vCenter server   (6)eight vSphere hosts  Which configuration minimally satisfies these requirements?()A、Three IBMBladeCenter S chassis, three Brocade Fibre modules, six Ethernet modulesB、Three IBMBladeCenter E chassis, three Brocade Fibre modules, six Ethernet modulesC、Four IBMBladeCenter H chassis, four QLogic Fibre Channel modules, eight Ethernet modulesD、Three IBMBladeCenter H chassis, three QLogic Fibre Channel modules, six Ethernet modules

An industrial sector customer has requested an IBM System x3755 for a high performance computing application. Pricing is the most sensitive decision factor for this customer. They are looking for an entry-level storage solution because the application needs to access about 12 TB of data, with an expected future growth of 10-15 percent. As this is the only server accessing this amount of data, the customer does not want to have a SAN.  What should the System x Sales Specialist recommend? ()A、DS3300 iSCSI-based solutionB、One MegaRAID 8480 card with four EXP3000 unitsC、DS4000 Fibre Channel solution with EXP810 expansion unitsD、DS3400 Fibre Channel solutionWArialZ

单选题During a planning session, the customer indicates that they intend to build two independent two- Node clusters (cluster ’A’ and ’B’) that will be provided shared storage form an IBM TotalStorage FAStT900 server. The customer intends to present 2 LUNs to cluster ’A’, and 2 LUNs to cluster ’B’. All hosts will be dual attached via fibre.  What additional hardware or software is necessary to make this a valid configuration?()A SAN switchesB Fibre channel Hub(s)C IBM Storage Manager AgentsD IBM Subsystem Device Driver

单选题Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()ACreate LVM mirrors between LUNsBMPIO is necessary as the device driverCUse separate fibre adapters in the Virtual IO Server for each LUNDVirtual IO Server is a disk subsystem and must control the LUNs behind it

单选题A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()AConfigure 2 CFFh combination fibre channel / gigabit Ethernet adaptersBConfigure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterCConfigure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterDConfigure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

单选题A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()ALPAR-A with 1Gb FC HBA and SAN connectionBLPAR-B with 2Gb FC HBA and SAN connectionCLPAR-C with 4Gb FC HBA and SAN connectionDLPAR-D with 8Gb FC HBA and SAN connection

单选题A cluster administrator has been asked to install HACMP on two nodes with the following  hardware:   -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage.  In order to eliminate single points of failure,the administrator should first add which of the following:()A an additional 1GB RAM to each node.B Another bootable mirrored disk drive.C A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.D Nothing,because this is a viable cluster solution with no single points of failure.

单选题A customer is ready to order a pSeries solution.  However, the pSeries technical specialist is unsure whether the customer preferred the fibre channel or the external SCSI disk attachment option.  What is the most appropriate action for the specialist to take next?()AAsk the customer to confirm which option is best for their environment.BOrder the fibre channel option and purchase a converter later if necessary.COrder both SCSI and fibre channel adapters to cover both potential options.DInform the customer that fibre channel was selected for performance reasons.

单选题An industrial sector customer has requested an IBM System x3755 for a high performance computing application. Pricing is the most sensitive decision factor for this customer. They are looking for an entry-level storage solution because the application needs to access about 12 TB of data, with an expected future growth of 10-15 percent. As this is the only server accessing this amount of data, the customer does not want to have a SAN.  What should the System x Sales Specialist recommend? ()ADS3300 iSCSI-based solutionBOne MegaRAID 8480 card with four EXP3000 unitsCDS4000 Fibre Channel solution with EXP810 expansion unitsDDS3400 Fibre Channel solutionWArialZ

单选题Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()A Disk heartbeatB Error notificationC Event notificationD Application monitor

单选题A banking customer has the following requirements for an IBM BladeCenter solution with high speed fibre channel: (1)four 4-socket Microsoft SQL servers with two hot swap SAS drives  (2)two physical Microsoft Active Directory Servers  (3)twenty-two physical Citrix servers  (4)three physical Web servers (5)one physical vCenter server   (6)eight vSphere hosts  Which configuration minimally satisfies these requirements?()AThree IBMBladeCenter S chassis, three Brocade Fibre modules, six Ethernet modulesBThree IBMBladeCenter E chassis, three Brocade Fibre modules, six Ethernet modulesCFour IBMBladeCenter H chassis, four QLogic Fibre Channel modules, eight Ethernet modulesDThree IBMBladeCenter H chassis, three QLogic Fibre Channel modules, six Ethernet modules

单选题The customer currently has 20 servers with 1 TB of internal capacity on each server. The serverscommunicate over 10/100/1000 Ethernet. The customer would like to move to a shared storagesubsystem with Fibre Channel hard drives. Budget is a key issue for them. Which option wouldallow for the lowest cost to implement?()AIBM DS8700 BIBM N6040 CIBM Storwize V7000 DIBM XIV Storage System

单选题A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server BCisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module CFibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module DCisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

单选题A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()ADual power supplies.BTwice the amount of disk.CTwo dual-port LHEA adapters.DTwo dual-port fibre channel adapters.

单选题A small organization is purchasing a POWER5 to consolidate four applications. Currently, each application has two Host Bus Adapters (HBA) connected to an Enterprise Storage Server (ESS). The customer is concerned about the cost of purchasing eight new HBAs. Which feature of virtualization will be most beneficial to this organization?()AVirtual EthernetBMicro-PartitioningCVirtual I/O ServerDCapped and uncapped partitions