单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator

单选题
Refrigerant is circulated through a refrigeration system by the ().
A

compressor

B

condenser

C

expansion valve

D

evaporator


参考解析

解析: 暂无解析

相关考题:

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题A refrigerant boils and vaporizes in the () in a compression refrigeration system.Aliquid receiverBcompressorCcondenserDcooling coil

单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().Aa shortage of refrigerant in the systemBair in the systemCan accumulation of liquid refrigerant in the crankcaseDa shortage of oil in the crankcase

单选题Refrigeration system compressor crankcase sweating is an indication of ().Ainsufficient lube oil circulating through the systemBexcessive circulation of lube oil through the systemCinsufficient refrigerant in the systemDan overworked compressor

单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().Aflooding backBsuperheatingCoverflowingDrecycling

单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().Arestriction in refrigerant pipingBair and non-condensable gases in the condenserCwater in the refrigerantDflooding back of liquid refrigerant from the evaporator

单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator

单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.AcompressorBcondenserCthrottle valveDevaporator

单选题If a refrigeration system were short of refrigerant, the condition would result in ().Acontinuous running of the compressorBhigh suction pressureChigh discharge pressureDshort cycling of the compressor on the water failure switch

单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().Amaintain adequate coil back pressureBprohibit flashing in the liquid lineCreduce refrigerant volume in the systemDreduce compressor discharge line loading

单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().Atoo much refrigerant in the systemBoil entrained in the refrigerantCless than a full charge of refrigerant in the systemDice crystals forming in the refrigerant

单选题Moisture is removed from a refrigeration system by().Ableeding refrigerant from the condenserBopening a drain petcock on the oil separatorCcondensing the water in the heat exchangerDusing a dehydrator cartridge

单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().Apassing it through the expansion valveBcondensing refrigerant in the system condenserCpassing the gaseous refrigerant through the heat interchanger on the suction side of the compressorDmaintaining a high pressure on the systems receiver

单选题In which of the listed refrigeration system components does superheating of the refrigerant take place?()AExpansion valveBEvaporatorCDrierDReceiver

单选题A liquid sight flow indicator in a refrigeration system is examined and gas bubbles are noted in motion with the fluid flowThis means ().Athe system is fully chargedBthere is air leaking in from the condenserCice crystals are forming in the refrigerantDthe system contains less than a full charge of refrigerant

单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()AThe liquid receiver functions to collect and remove non-condensable gasesBA thermostatic expansion valve is used to control refrigerated space temperatureCRefrigerant temperature in an evaporator is directly related to refrigerant pressureDDehydrators must be used continuously in a refrigeration system

单选题Saltwater is typically provided to a refrigeration system to ().Acool the expansion valveBprevent refrigerant superheatingCcondense the refrigerant gasDprevent motor overheating

单选题Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()ASub-cooled liquidBSub-cooled vaporCSuperheated vaporDLiquid

单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().Asub-cooled liquidBhigh temperature liquidCoil saturated liquidDsuperheated vapor

单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()Asuction service valve as a vaporBsuction service valve as a liquidCdischarge service valve as a vaporDcharging valve as a liquid

单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().AliquidBdry saturated gasCwet saturated gasDsuperheated vapor

单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system

单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor

单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().Acarbon deposits on the compressor suction valvesBthe evaporator temperature to increaseCrapid corrosion of the thermal expansion valveDno operating problems