单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.AcompressorBcondenserCthrottle valveDevaporator
单选题
In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.
A
compressor
B
condenser
C
throttle valve
D
evaporator
参考解析
解析:
暂无解析
相关考题:
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题The latent heat of evaporation is dissipated in the () in a compression refrigeration system.AevaporatorBcondenserCexpansion valveDcompressor
单选题A refrigerant boils and vaporizes in the () in a compression refrigeration system.Aliquid receiverBcompressorCcondenserDcooling coil
单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().Aa shortage of refrigerant in the systemBair in the systemCan accumulation of liquid refrigerant in the crankcaseDa shortage of oil in the crankcase
单选题The refrigerant flows through the evaporator, where it () heat from the refrigerated space.AextractsBreleasesCgives noDabsorbs no
单选题The evaporating pressure in R22 vapor compression refrigeration plant should be () atmospheric.AbelowBaboveCequal toDmuch larger than
单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().Acompressor;condenserBcondenser;evaporatorCthrottle valve;evaporatorDevaporator;condenser
单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator
单选题The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()Alatent heat of expansionBsensible heat of condensationCheat of compressionDall of the above
单选题Insufficient refrigerant in a refrigeration plant may result in ().Ahigh discharge pressureBfrosting of the crankcaseChigh temperature of the overboard waterDlow suction pressure of compressor
单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.AfilterBfilter drierCheat exchangerDair cooler
单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().Amaintain adequate coil back pressureBprohibit flashing in the liquid lineCreduce refrigerant volume in the systemDreduce compressor discharge line loading
单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().Atoo much refrigerant in the systemBoil entrained in the refrigerantCless than a full charge of refrigerant in the systemDice crystals forming in the refrigerant
单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().Apassing it through the expansion valveBcondensing refrigerant in the system condenserCpassing the gaseous refrigerant through the heat interchanger on the suction side of the compressorDmaintaining a high pressure on the systems receiver
单选题Before charging a refrigeration unit, the refrigerant charging lines should be()Aflushed with clean refrigerant oilBpurged with the refrigerantCwashed with an ammonia and alcohol solutionDgrounded to compressor
单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().Arefrigerant boiling out of solution from the lube oilBliquid refrigerant flooding the compressor and systemClube oil viscosity being reduced by refrigerant dilutionDcompressor suction pressure suddenly increasing
单选题In a compression refrigeration cycle, the temperature of the liquid refrigerant experiences its greatest decrease in the().AevaporatorBcompressorCexpansion valveDcondenser
单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator
单选题When refrigerant leaves the receiver, it flows next on to the ().Aevaporator coilsBliquid strainerCcompressorDcondenser
单选题Saltwater is typically provided to a refrigeration system to ().Acool the expansion valveBprevent refrigerant superheatingCcondense the refrigerant gasDprevent motor overheating
单选题In a compression refrigeration plant the hot, high pressure refrigerant gas is cooled by the sea water and becomes liquid in the ().AcompressorBcondenserCthrottle valveDevaporator
单选题In the refrigeration compressor the temperature of the vapor is () by compression.AraisedBrisenCreducedDmaintained constant
单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureAany of (1) and (3)Bany of (1) and (2)Cany of (2) and (3)Dany of (1), (2) and (3)
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system
单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor