单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system
单选题
When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().
A
increase the amount of cooling water to the condenser
B
decrease the amount of cooling water to the condenser
C
add more refrigerant to the system
D
remove some refrigerant from the system
参考解析
解析:
暂无解析
相关考题:
If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve
When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first
Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressorA.has run continuously for a long periodB.suction pressure is below normalC.oil level is below normalD.starts after a long idle period
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().Aflooding backBsuperheatingCoverflowingDrecycling
单选题An important consideration in selecting a lubricating oil for use in a refrigeration compressor is for the oil to ()Ahave a high viscosity indexBmix readily with refrigerantChave a high freezing pointDhave a low pour point
单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().Athe compressor suction pressure is not too highBall air is purged from the pump and charging fittingsCthe high pressure cutout switch is held open to prevent accidental startingDthe condenser is completely shutdown first
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().Apurge the condenser if the waterside is dirtyBcheck for proper water flow through the condenserCincrease the high pressure cutout settingDreduce the cooling water flow
单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().Aliquid strainerBrefrigerant inlet of the condenserCinlet side of the evaporatorDsuction side of the compressor
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow
单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().Arun continuouslyBnot startChave high discharge pressureDshort cycle on the high pressure switch
单选题()are supplied by main switchboard directly.ASuez Canal searchlight, air compressor and air conditioning compressorBAir compressor, boiler blower and refrigeration plantCBoiler blower, Suez Canal searchlight and refrigeration plantDSuez canal searchlight, air compressor and boiler blower
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively
单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().Aalways be wide open when the compressor restartsBcontinue to operate as if the system were in operationCremain open until evaporator pressure equalizes, then close until the compressor restartsDalways be completely closed until the compressor restarts
单选题In the refrigeration system, a shortage of refrigerant is indicated by ().Athe compressor short cycling on high pressure cut out switchBhigh suction pressureChigh head pressureDbubbles in the sight glass
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve
单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()Asystem is overcharged with refrigerantBsystem is low on refrigerantCdischarge valves are leaking excessivelyDdischarge valves are leaking slightly
单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureAany of (1) and (3)Bany of (1) and (2)Cany of (2) and (3)Dany of (1), (2) and (3)
单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.Ahas continuously for a long periodBsuction pressure is below normalCoil level is below normalDstarts after a long idle period
单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()AThe condenser and the expansion valveBThe king valve and the solenoid valveCThe compressor and the expansion valveDThe condenser and the solenoid valve
单选题When a refrigeration compressor motor fails to start, the FIRST thing that should be checked for is a ().Aloose expansion valve control bulbBlow differential setting on the H-PcutoutCblown fuse in the motor circuitDfaulty suction pressure regulator