单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().Asub-cooled liquidBhigh temperature liquidCoil saturated liquidDsuperheated vapor
单选题
The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().
A
sub-cooled liquid
B
high temperature liquid
C
oil saturated liquid
D
superheated vapor
参考解析
解析:
暂无解析
相关考题:
The temperature of the refrigerant in the evaporator coil depends mostly upon the ___.A.refrigerant pressure in the evaporatorB.cooling water temperature to the condenserC.heat load in the refrigerator compartmentD.solenoid valve in the liquid line
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题A refrigerant boils and vaporizes in the () in a compression refrigeration system.Aliquid receiverBcompressorCcondenserDcooling coil
单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().Aa shortage of refrigerant in the systemBair in the systemCan accumulation of liquid refrigerant in the crankcaseDa shortage of oil in the crankcase
单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().Arestriction in refrigerant pipingBair and non-condensable gases in the condenserCwater in the refrigerantDflooding back of liquid refrigerant from the evaporator
单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator
单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().Amaintain adequate coil back pressureBprohibit flashing in the liquid lineCreduce refrigerant volume in the systemDreduce compressor discharge line loading
单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().Atoo much refrigerant in the systemBoil entrained in the refrigerantCless than a full charge of refrigerant in the systemDice crystals forming in the refrigerant
单选题The heat gained per pound of refrigerant in the evaporator is known as the().Alatent heat of vaporizationBsensible heatCrefrigerating effectDspecific heat of vaporization
单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().Apassing it through the expansion valveBcondensing refrigerant in the system condenserCpassing the gaseous refrigerant through the heat interchanger on the suction side of the compressorDmaintaining a high pressure on the systems receiver
单选题Before charging a refrigeration unit, the refrigerant charging lines should be()Aflushed with clean refrigerant oilBpurged with the refrigerantCwashed with an ammonia and alcohol solutionDgrounded to compressor
单选题Because the expansion valve is just () way open, the refrigerant is under low pressure in the evaporator.AlittleBfewCa littleDa few
单选题The saturation temperature of the refrigerant must be () that required in the evaporator refrigerated space.AaboveBbelowCequal toDNone of the above
单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()AThe liquid receiver functions to collect and remove non-condensable gasesBA thermostatic expansion valve is used to control refrigerated space temperatureCRefrigerant temperature in an evaporator is directly related to refrigerant pressureDDehydrators must be used continuously in a refrigeration system
单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator
单选题When refrigerant leaves the receiver, it flows next on to the ().Aevaporator coilsBliquid strainerCcompressorDcondenser
单选题Saltwater is typically provided to a refrigeration system to ().Acool the expansion valveBprevent refrigerant superheatingCcondense the refrigerant gasDprevent motor overheating
单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().Achange the expansion valve adjustmentBreadjust the water regulating valve to increase the flow of waterCpurge air from the condenserDclean the waterside of the condenser
单选题In practice, the refrigerant flow after the evaporator is designed to ensure that the vapor leaving the evaporator is slightly ().AsaturatedBsuper-cooledCwetDsuperheated
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system
单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor
单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().Acarbon deposits on the compressor suction valvesBthe evaporator temperature to increaseCrapid corrosion of the thermal expansion valveDno operating problems