单选题When an auxiliary boiler is panting and emitting black smoke, you should ().Aincrease the fuel oil temperatureBdecrease the fuel oil temperatureCdecrease the fuel oil supply pressureDincrease the air supply

单选题
When an auxiliary boiler is panting and emitting black smoke, you should ().
A

increase the fuel oil temperature

B

decrease the fuel oil temperature

C

decrease the fuel oil supply pressure

D

increase the air supply


参考解析

解析: 暂无解析

相关考题:

The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness

When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply

单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()Acold fuel oilBlow fuel oil pressureClow atomizing steam pressureDwater in the fuel oil

单选题The most common cause of scale formation in an auxiliary boiler is ()Aconcentrations of calcium sulfate in the boiler waterBfuel oil in the feed waterCimproper treatment of the feed water with calcium sulfateDexcessive feed water alkalinity

单选题The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()Awill be modulated in proportionBwill be modulated in proportion and integralCwill be modulated in proportion and differentialDwill not be modulated at all

单选题Black smoke coming from a boiler can be caused by ().Alow water levelBhigh water levelCexcessively high fuel pressureDlow oil temperature

单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished

单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().Aoperating the boiler at less than normal water levelBinstalling fins on the firesides of water-tubesCincreasing the amount of excess air to the burnersDtreating the boiler water with chemical oxygen scavengers

单选题When an auxiliary boiler is panting and emitting black smoke, you should ().Aincrease the fuel oil temperatureBdecrease the fuel oil temperatureCdecrease the fuel oil supply pressureDincrease the air supply

单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().Asteam stop valveBdry pipeCfeedwater systemDgenerating tubes

单选题High exhaust temperature and black smoke exhausting from an auxiliary diesel engine can be caused by ().Aengine overloadBlow combustion temperatureCplugged fuel nozzle holesDexcessive compression pressure

单选题The water in an auxiliary boiler should be tested daily for ().Adissolved oxygenBchloridesCsludgeDdissolved nitrogen

单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()Asalinity is abnormally highBsteam demand is too highCwater level is abnormally lowDfeedwater flow is low

单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()Asteam demand is highBsalinity is highCsafety valve simmersDburner flame is extinguished

单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().Aair supply is shut offBfuel supply is shut offCwater supply is shut offDsafety valve lifts

单选题Exhaust pipes for separate diesel engines can be combined only when ()Aspace limitations prevent separately run pipesBthe engines are small auxiliary unitsCthey are arranged to prevent gas backflow to each engineDa waste heat boiler is installed

单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain

单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()Adefective solenoid valveBdirty fuel nozzleCgrounded high tension leadDfaulty ignition cable connector

单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes

单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()Aprecipitate silica from solutionBreduce corrosion in the heating coilCprevent clogging and erosion in the coilDmaintain zero water hardness

单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces

单选题Black smoke coming from a boiler can be caused by ().Alow water levelBlow oil pressureCexcessively high fuel pressureDan improper air/fuel ratio

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity

单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A10B7C4D1

单选题The water in an operating auxiliary boiler should be tested for alkalinity and chloride content each().AhourBdayCweekDmonth

单选题Which action should be taken when an auxiliary boiler in is operation?()AClean all electrical connectionsBLift the relief valves by handCInspect and clean all solenoid valvesDInspect for oil and water leaks