单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A10B7C4D1

单选题
Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().
A

10

B

7

C

4

D

1


参考解析

解析: 暂无解析

相关考题:

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness

Before the seas get rough, it is a good safety practice to ______.A.secure loose gearB.move quickly about the shipC.increase lightingD.shutdown auxiliary equipment

A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

单选题The most common cause of scale formation in an auxiliary boiler is ()Aconcentrations of calcium sulfate in the boiler waterBfuel oil in the feed waterCimproper treatment of the feed water with calcium sulfateDexcessive feed water alkalinity

单选题The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()Awill be modulated in proportionBwill be modulated in proportion and integralCwill be modulated in proportion and differentialDwill not be modulated at all

单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished

单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().Aoperating the boiler at less than normal water levelBinstalling fins on the firesides of water-tubesCincreasing the amount of excess air to the burnersDtreating the boiler water with chemical oxygen scavengers

单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().Asteam stop valveBdry pipeCfeedwater systemDgenerating tubes

单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().Afuel pump failureBfan motor failureCincreased feedwater consumptionDdecreased boiler efficiency

单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()Afiring for extended periods in the low fire modeBoverheating, due to waterside depositsCvarying the water level above the crown sheetDcarrying excessive alkalinity in the boiler water

单选题The water in an auxiliary boiler should be tested daily for ().Adissolved oxygenBchloridesCsludgeDdissolved nitrogen

单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()Asalinity is abnormally highBsteam demand is too highCwater level is abnormally lowDfeedwater flow is low

单选题The water in an auxiliary boiler should be chemically tested daily for alkalinity and()Asoap hardnessBnitrog encontentCchloride contentDdissolved CO2

单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()Asteam demand is highBsalinity is highCsafety valve simmersDburner flame is extinguished

单选题Which one is not the normal operation for boiler shutdown?()ACarry out soot blowing if permissibleBChange fuel supply to diesel oilCClose steam stop valves on boiler when pressure is reducedDDrain boiler empty when it has cooled down

单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()Aexcessive purging before lighting offBinsufficient trail for ignition periodCa faulty transformer in the ignition circuitDinsufficient purging before lighting off

单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain

单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdrum level to stabilize

单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()Aprecipitate silica from solutionBreduce corrosion in the heating coilCprevent clogging and erosion in the coilDmaintain zero water hardness

单选题The water in an auxiliary boiler should be tested for chloride content to determine ().Atotal dissolved solidsBsalt contaminationCwater hardnessDchlorine contamination

单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces

单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Acompletely drain the boiler in an emergencyBprevent sludge from forming in the drumCremove floating impurities from the boiler water surfaceDremove settled solids from the water drum

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity

单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdram level to stabilize

单选题The water in an operating auxiliary boiler should be tested for alkalinity and chloride content each().AhourBdayCweekDmonth