When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply
When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.
A.increase the fuel oil temperature
B.decrease the fuel oil temperature
C.decrease the fuel oil supply pressure
D.increase the air supply
相关考题:
The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure
Have you ever served the auxiliary engine to combustion heavy oil? What should be borne in mind when transferring oil; from heavy oil to light oil?
what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
When issuing the duplicate database command, you use the parameter DB_FILE_NAME_CONVERT. For what purpose do you use this parameter?() A、 To indicate the location of the auxiliary-instance online redo logs.B、 To indicate the location of the target database datafiles.C、 To indicate the location of the auxiliary-instance control file and online redo logs.D、 To indicate the location of the auxiliary-instance database datafiles.E、 This is not a valid parameter when duplicating a database.
单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()Acold fuel oilBlow fuel oil pressureClow atomizing steam pressureDwater in the fuel oil
单选题When issuing the duplicate database command, you use the parameter DB_FILE_NAME_CONVERT. For what purpose do you use this parameter?()A To indicate the location of the auxiliary-instance online redo logs.B To indicate the location of the target database datafiles.C To indicate the location of the auxiliary-instance control file and online redo logs.D To indicate the location of the auxiliary-instance database datafiles.E This is not a valid parameter when duplicating a database.
单选题Black smoke coming from a boiler can be caused by ().Alow water levelBhigh water levelCexcessively high fuel pressureDlow oil temperature
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished
单选题When an auxiliary boiler is panting and emitting black smoke, you should ().Aincrease the fuel oil temperatureBdecrease the fuel oil temperatureCdecrease the fuel oil supply pressureDincrease the air supply
单选题High exhaust temperature and black smoke exhausting from an auxiliary diesel engine can be caused by ().Aengine overloadBlow combustion temperatureCplugged fuel nozzle holesDexcessive compression pressure
单选题The water in an auxiliary boiler should be tested daily for ().Adissolved oxygenBchloridesCsludgeDdissolved nitrogen
单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()Asalinity is abnormally highBsteam demand is too highCwater level is abnormally lowDfeedwater flow is low
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()Asteam demand is highBsalinity is highCsafety valve simmersDburner flame is extinguished
单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().Aair supply is shut offBfuel supply is shut offCwater supply is shut offDsafety valve lifts
单选题Exhaust pipes for separate diesel engines can be combined only when ()Aspace limitations prevent separately run pipesBthe engines are small auxiliary unitsCthey are arranged to prevent gas backflow to each engineDa waste heat boiler is installed
单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain
单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()Adefective solenoid valveBdirty fuel nozzleCgrounded high tension leadDfaulty ignition cable connector
单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()Aprecipitate silica from solutionBreduce corrosion in the heating coilCprevent clogging and erosion in the coilDmaintain zero water hardness
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces
单选题Black smoke coming from a boiler can be caused by ().Alow water levelBlow oil pressureCexcessively high fuel pressureDan improper air/fuel ratio
单选题If you observe smoke coming from the turbocharger of an auxiliary diesel engine, you should()Acheck the air filter for obstructionBcheck for an exhaust leakCcheck the exhaust temperatureDsecure the engine
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity
单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().Acheck and regulate the water levelBclose the air cock once fires are litCblowdown the gage glassDcrack the steam stop to assure protective steam flow
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A10B7C4D1
单选题If an operating auxiliary boiler has a water pH reading of 7, you should ().Abottom blow the boilerBtreat the water with caustic sodaCtreat the water with chemical scavengersDreduce the water alkalinity to recommended readings
单选题Which action should be taken when an auxiliary boiler in is operation?()AClean all electrical connectionsBLift the relief valves by handCInspect and clean all solenoid valvesDInspect for oil and water leaks