单选题The feed water to the boiler will comprise ().AcondensateBa small amount of make-up feedCA and BDNone of the above

单选题
The feed water to the boiler will comprise ().
A

condensate

B

a small amount of make-up feed

C

A and B

D

None of the above


参考解析

解析: 暂无解析

相关考题:

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

辅助给水系统/应急给水系统 auxiliary feed water system/emergency feed water system

单选题Which of the following items is necessary for all waste heat boiler installations, regardless of design or manufacturer? ()AControl of evaporationBA separate means to prevent feed-water contaminationCPower circulating pumpDSuper-heater

单选题The most common cause of scale formation in an auxiliary boiler is ()Aconcentrations of calcium sulfate in the boiler waterBfuel oil in the feed waterCimproper treatment of the feed water with calcium sulfateDexcessive feed water alkalinity

单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum

单选题What is NOT a function of the steam drum of a marine water-tube boiler().AReceives saturated steam from the generating tubesBServes as a reservoir of boiler feed waterCHolds internal fittings for separation of moisture from steamDCollects steam exhausted from the turbines

单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()Anatural circulation of the water in the water tube boiler is better than that in the fire tube boilerBfor the same output the water tube boiler will carry less mass of water compared with the fire tube boilerCthe water tube boiler will cost shorter time for steam raisingDthe water tube boiler require lower skill in operating and maintaining

单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished

单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().Aoperating the boiler at less than normal water levelBinstalling fins on the firesides of water-tubesCincreasing the amount of excess air to the burnersDtreating the boiler water with chemical oxygen scavengers

单选题The boiler feed water check valves are located on the ()Afeed pump suction lineBhot wellCshell of the feed heaterDfeed lines to the boiler

单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Aremove suspended and precipitated solids from the boiler waterBcompletely drain the boiler in an emergency situationCprevent hardened scale deposits in the water drumDremove floating impurities from the oily water surface

单选题The correct pH value of boiler water is achieved by continuous addition of a suitable () to the feed.AacidBalkaliCsaltDNone of the above

单选题The valve that prevents water from backing out of the boiler into the feed line is the().Abottom-blow valveBskin valveCfeed-check valveDfeed-stop valve

单选题The second stage feed-water temperature and shell absolute pressure in a multistage, flash type, distilling plant is ()Ahigher than the first stage feed-water temperature and absolute shell pressureBlower than the first stage feed-water temperature and absolute shell pressureCthe same as the first stage feed-water temperature and absolute shell pressureDnot related to the feed-water temperature and absolute shell pressure

单选题A feed pump for an auxiliary boiler might lose suction if the ().Aboiler water level is lowBfeedwater is too hotCboiler steam demand is lowDfeedwater is too cold

单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()AHigh oxygen concentrationBLow pHCProper alkalinityDAll of the above

单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().Aensure feed water flow into the boilerBkeep the steam drum pressure highCprevent water hammer in the feed lineDhelp the feed water flash to steam

单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes

单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()Aprecipitate silica from solutionBreduce corrosion in the heating coilCprevent clogging and erosion in the coilDmaintain zero water hardness

单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure

单选题When steam is being raised on a boiler, the water level will normally ().Adrop as the boiler warms upBrise as the boiler warms upCremain unchanged until the boiler is hot enoughDrise and fall with the steam demand

单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces

单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Acompletely drain the boiler in an emergencyBprevent sludge from forming in the drumCremove floating impurities from the boiler water surfaceDremove settled solids from the water drum

单选题As for an oil-fired boiler if at a normal steaming condition and water goes out of sight in gauge glasses the action you should take is: () (1) secure oil to fires (2) increase feed pump pressureA(1)B(1)and(2)C(2)Dneither(1)nor(2)

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity