单选题When steam is being raised on a boiler, the water level will normally ().Adrop as the boiler warms upBrise as the boiler warms upCremain unchanged until the boiler is hot enoughDrise and fall with the steam demand

单选题
When steam is being raised on a boiler, the water level will normally ().
A

drop as the boiler warms up

B

rise as the boiler warms up

C

remain unchanged until the boiler is hot enough

D

rise and fall with the steam demand


参考解析

解析: 暂无解析

相关考题:

The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure

The water level in the gauge glass when a boiler is operating is _____ when the boiler is shut down.A.lower thanB.higher thanC.belowD.equal to

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

The water level showing in a boiler water gauge glass is usually ( ) duringworking.A.higher than the actual drum water levelB.equal to the actual drum water levelC.increasing due to steam condensation in the glassD.lower than actual drum wafer level

what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum

单选题You should frequently compare drum-mounted and remote-reading water level indicators() between these have contributed to failures because of overheating through shortage of water, when a boiler was being oil-fired.AdescriptionsBdiscrepanciesCdifferentDdeflections

单选题The steam boiler is part of a closed loop steam, whereby, after the energy of the steam is used up and it becomes water again, () is collected and returned back to the boiler for heating up again to steam.Athe formerBthe firstCthe latterDthe last

单选题What is NOT a function of the steam drum of a marine water-tube boiler().AReceives saturated steam from the generating tubesBServes as a reservoir of boiler feed waterCHolds internal fittings for separation of moisture from steamDCollects steam exhausted from the turbines

单选题When a sudden increase in steam demand occurs from the boiler, the water level in the drum at the higher pressure will()Arise quicklyBrise slowlyCdrop quicklyDdrop slowly

单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()Anatural circulation of the water in the water tube boiler is better than that in the fire tube boilerBfor the same output the water tube boiler will carry less mass of water compared with the fire tube boilerCthe water tube boiler will cost shorter time for steam raisingDthe water tube boiler require lower skill in operating and maintaining

单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished

单选题When a sudden increase in steam demand comes to normal, the drum pressure will and water level in the drum will().Arise, rise alsoBrise, dropCdrop, riseDdrop, drop also

单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.Amain stem stop valveBauxiliary steam stop valveCfeed check or control valveDblow down valve

单选题When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().AswellBshrinkageCflash offDlack of water

单选题When preparing an engine for water temperature()Ashould be kept at a proper level by a coolerBshould be raised to about 80℃ by a heaterCshould be raised graduallyDshould be lowered to about 60℃

单选题A feed pump for an auxiliary boiler might lose suction if the ().Aboiler water level is lowBfeedwater is too hotCboiler steam demand is lowDfeedwater is too cold

单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().Aensure feed water flow into the boilerBkeep the steam drum pressure highCprevent water hammer in the feed lineDhelp the feed water flash to steam

单选题Water level controllers of the boiler must be kept operable to protect external steam-using plant from water “()” danger.Acarry offBcarry downCcarry onDcarry over

单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes

单选题The water level showing in a boiler water gauge glass is usually () during working.Ahigher than the actual drum water levelBequal to the actual drum water levelCincreasing due to steam condensation in the glassDlower than actual drum water level

单选题If in doubt as to the true water level when a boiler is being oil-fired, you should ().Atake no measuresBextinguish the fire as soon as possibleCfeed water to the boilerDopen the blow down valve

单选题(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.AAn economizerBAn attemperatorCA water dramDA down-comer tube

单选题The water level in the gauge glass when a boiler is operating is () when the boiler is shut down.Alower thanBhigher thanCbelowDequal to

单选题When a boiler is operating, the water level in the gauge glass reads () when the boiler is shut down.Alower thanBhigher thanCas much asDthe same as

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity