单选题The boiler feed water check valves are located on the ()Afeed pump suction lineBhot wellCshell of the feed heaterDfeed lines to the boiler
单选题
The boiler feed water check valves are located on the ()
A
feed pump suction line
B
hot well
C
shell of the feed heater
D
feed lines to the boiler
参考解析
解析:
暂无解析
相关考题:
The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low
what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
单选题Which of the following items is necessary for all waste heat boiler installations, regardless of design or manufacturer? ()AControl of evaporationBA separate means to prevent feed-water contaminationCPower circulating pumpDSuper-heater
单选题The most common cause of scale formation in an auxiliary boiler is ()Aconcentrations of calcium sulfate in the boiler waterBfuel oil in the feed waterCimproper treatment of the feed water with calcium sulfateDexcessive feed water alkalinity
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum
单选题What is NOT a function of the steam drum of a marine water-tube boiler().AReceives saturated steam from the generating tubesBServes as a reservoir of boiler feed waterCHolds internal fittings for separation of moisture from steamDCollects steam exhausted from the turbines
单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().Arelieve excess fuel oil pressure during the “off” fire cycleBadmit water to the dry pipeCthrottle the forced draft fan output for proper combustionDreduce excess steam pressure in the boiler
单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()Anatural circulation of the water in the water tube boiler is better than that in the fire tube boilerBfor the same output the water tube boiler will carry less mass of water compared with the fire tube boilerCthe water tube boiler will cost shorter time for steam raisingDthe water tube boiler require lower skill in operating and maintaining
单选题In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()AThe safety valve escape piping should be disconnected from the valve body and a blank insertedBThe boiler vent valves should be openedCAll hand-hole/manhole covers should be tightened up as much as possible to preclude any leaksDAll of the above
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().Aoperating the boiler at less than normal water levelBinstalling fins on the firesides of water-tubesCincreasing the amount of excess air to the burnersDtreating the boiler water with chemical oxygen scavengers
单选题In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()AThe safety valve escape piping should be disconnected from the valve body and a blank insertedBThe boiler vent valves should be openedCAll handhole/manhole covers should be tightened up as much as possible to preclude any leaksDAll of the above
单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.Amain stem stop valveBauxiliary steam stop valveCfeed check or control valveDblow down valve
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Aremove suspended and precipitated solids from the boiler waterBcompletely drain the boiler in an emergency situationCprevent hardened scale deposits in the water drumDremove floating impurities from the oily water surface
单选题The valve that prevents water from backing out of the boiler into the feed line is the().Abottom-blow valveBskin valveCfeed-check valveDfeed-stop valve
单选题The second stage feed-water temperature and shell absolute pressure in a multistage, flash type, distilling plant is ()Ahigher than the first stage feed-water temperature and absolute shell pressureBlower than the first stage feed-water temperature and absolute shell pressureCthe same as the first stage feed-water temperature and absolute shell pressureDnot related to the feed-water temperature and absolute shell pressure
单选题A feed pump for an auxiliary boiler might lose suction if the ().Aboiler water level is lowBfeedwater is too hotCboiler steam demand is lowDfeedwater is too cold
单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()AHigh oxygen concentrationBLow pHCProper alkalinityDAll of the above
单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().Aensure feed water flow into the boilerBkeep the steam drum pressure highCprevent water hammer in the feed lineDhelp the feed water flash to steam
单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes
单选题Impurities from the boiler water surface can be removed through the ().Asafety valveBblow down valveCscum valveDfeed check valve
单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Acompletely drain the boiler in an emergencyBprevent sludge from forming in the drumCremove floating impurities from the boiler water surfaceDremove settled solids from the water drum
单选题The feed water to the boiler will comprise ().AcondensateBa small amount of make-up feedCA and BDNone of the above
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity
单选题Which action should be taken when an auxiliary boiler in is operation?()AClean all electrical connectionsBLift the relief valves by handCInspect and clean all solenoid valvesDInspect for oil and water leaks