单选题A feed pump for an auxiliary boiler might lose suction if the ().Aboiler water level is lowBfeedwater is too hotCboiler steam demand is lowDfeedwater is too cold

单选题
A feed pump for an auxiliary boiler might lose suction if the ().
A

boiler water level is low

B

feedwater is too hot

C

boiler steam demand is low

D

feedwater is too cold


参考解析

解析: 暂无解析

相关考题:

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

辅助给水系统/应急给水系统 auxiliary feed water system/emergency feed water system

单选题The most common cause of scale formation in an auxiliary boiler is ()Aconcentrations of calcium sulfate in the boiler waterBfuel oil in the feed waterCimproper treatment of the feed water with calcium sulfateDexcessive feed water alkalinity

单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum

单选题A double suction centrifugal pump impeller has been installed in the reverse direction, and will ().Ahave a greater head capacityBoperate with increased impeller efficiencyCdischarge through the suction side of the pump casingDrequire more power to run the shaft

单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished

单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().Afuel pump failureBfan motor failureCincreased feedwater consumptionDdecreased boiler efficiency

单选题The boiler feed water check valves are located on the ()Afeed pump suction lineBhot wellCshell of the feed heaterDfeed lines to the boiler

单选题The static suction lift of a pump is the difference in elevation between the ().Acenterline of the pump and the level of the liquid in the suction well when the source of liquid is below the pumpBcenterline of the pump and the suction liquid level when the source of liquid is above the pumpCcenterline of the pump and the level of the discharge liquidDliquid levels of the suction and discharge

单选题Oxygen corrosion in auxiliary boilers is prevented by treating the boiler feed tank with either sodium ()Asulfite or hydrazineBsulfite or hygroscopic sulfiteCbromide or hydrazineDbromide or hygroscopic sulfite

单选题A pump is said to have "negative suction head" when the pump is located ().Abetween the suction and dischargeBbelow the liquid supplyCabove the liquid supplyDany of the above

单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()Asteam demand is highBsalinity is highCsafety valve simmersDburner flame is extinguished

单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain

单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()Aair or water in the furnaceBcombustion pulsesCfuel oil pump failureDflame failure

单选题A relief valve for a cargo pump is generally installed().Aafter the discharge valveBbetween the pump and discharge valveCafter the suction valveDbetween the pump and suction valve

单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdrum level to stabilize

单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()AHigh oxygen concentrationBLow pHCProper alkalinityDAll of the above

单选题Most pump manufacturers recommend that the suction piping dimension for centrifugal pumps be ().Aone size smaller than the pump suction nozzleBthe same size as the pump suction nozzleCone size larger than the pump suction nozzleDinstalled with a short radius elbow at the pump

单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().Aensure feed water flow into the boilerBkeep the steam drum pressure highCprevent water hammer in the feed lineDhelp the feed water flash to steam

单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes

单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure

单选题Which of the following conditions could cause the feed pump for an auxiliary boiler to lose suction?()AIncreased suction head pressureBDecreased feedwater temperatureCPump recirculating line being open too muchDExcessive feedwater temperature

单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces

单选题As for an oil-fired boiler if at a normal steaming condition and water goes out of sight in gauge glasses the action you should take is: () (1) secure oil to fires (2) increase feed pump pressureA(1)B(1)and(2)C(2)Dneither(1)nor(2)

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity

单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdram level to stabilize