单选题When installed for bilge pumping or ballast duty, centrifugal pumps require a () to remove air from the suction pipe.Aair chamberBhead lankCprimerDprime mover
单选题
When installed for bilge pumping or ballast duty, centrifugal pumps require a () to remove air from the suction pipe.
A
air chamber
B
head lank
C
primer
D
prime mover
参考解析
解析:
暂无解析
相关考题:
Accidental flooding of the engine room bilges by the bilge main is prevented by( ).A.stop-check valves installed in the bilge suction manifoldsB.using a positive displacement reciprocating bilge pumpC.installing educators in all bilge rose boxesD.installing a swing check before each bilge valve
When the ships is going to enter into the harborA.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest form high level one to lower level oneD.test emergency generator
With UMS, when the engine room is unwatched will control the main engineA.the bridge officer on watchB.the chief engineerC.the duty engineerD.the duty motorman
Permission is kindly ______ about 1000 tons of clean sea water ballast,as and when required for trimming purposes.A.requested to pump outB.requested pumping outC.requesting to pump outD.requesting pumping out
A vessel in ocean service that does not have an approved means of processing oily bilge slops or oily ballast must have ______.A.a fixed piping system for ballast discharge to a reception facilityB.a discharge outlet for the ballast system on each side of the weather deckC.one portable adapter for a shore connection to the ballast lineD.All of the above
Which statement is TRUE concerning the placard entitled Discharge of Oil Prohibited ________.A.It is required on all vesselsB.It may be located in a conspicuous place in the wheelhouseC.It may be located at the bilge and ballast pump control stationD.All of the above
Aboard damaged vessels, the MOST important consideration is preserving ______.A.bilge pumping capacityB.reserve buoyancyC.level attitudeD.Instability
淡水注入管()A、fresh water filling pipeB、sea water filling pipeC、ballast water filling pipeD、bilge water filling pipe
单选题Where tanks are arranged for either oil or ballast, () must be fitted in the pipeline.Aa change-over chestBa head tankCa emergency bilge pumpDan air cooler
单选题With UMS, when the engine room is unwatched () will control the main engine.Athe bridge officer on watchBthe chief engineerCthe duty engineerDthe duty motorman
单选题The bilge pump on a fishing vessel().Amust be fixed if the vessel exceeds 12 meters in lengthBmay be used as a fire pumpCmust be portable if there are more than 4 watertight compartmentsDmust be capable of pumping at least 450 gpm
单选题() is used for washing and drinking.AThe ballast systemBThe salt water systemCThe bilge systemDThe domestic system
单选题Permission is kindly () about 1000 tons of clean sea water ballast,as and when required for trimming purposes.Arequested to pump outBrequested pumping outCrequesting to pump outDrequesting pumping out
单选题An emergency bilge pumping system is provided and should be () of the main bilge pumping system, according to the SOLAS 74 Convention.AdependentBin dependentCin seriesDin parallel
单选题Upon arrival at a port, a vessel is not allowed () her ballast water, tanker washings or bilge water and other oily water at will.Ato dischargeBto be dischargedCdischargingDbeing discharged
单选题Accidental flooding of the engine room bilges by the bilge main is prevented by ().Astop-check valves installed in the bilge manifoldsBusing a positive displacement reciprocating bilge pumpCinstalling eductors in all bilge rose boxesDinstalling a swing check before each bilge valve
单选题During the PSC inspection, under the provisions of SOLAS 74, which one may not be regarded as clear grounds for ships’ detainment?()Afailure of the proper operation of emergency generatorBinsulation of piping including exhaust pipes in engine room contaminated by oilCimproper operation of bilge of bilge of bilge pumping arrangementsDdamaged sanitary pump
单选题The fire pumps must be capable of delivering a total quantity of water at a defined head, not less than () of the total bilge pumping capacity.Aone-thirdBtwo-thirdsCone-fourthDtwo-fourths
单选题Which statement is TRUE concerning the placard entitled Discharge of Oil Prohibited().AIt is required on all vesselsBIt may be located in a conspicuous place in the wheelhouseCIt may be located at the bilge and ballast pump control stationDAll of the above
单选题A compound gauge is typically installed on the ().Asuction side of a bilge pumpBexhaust manifold of an auxiliary dieselCdischarge line from an air compressorDchemical feed tank of an evaporator
单选题A vessel in ocean service that does not have an approved means of processing oily bilge slops or oily ballast must have().Aa fixed piping system for ballast discharge to a reception facilityBa discharge outlet for the ballast system on each side of the weather deckCone portable adapter for a shore connection to the ballast lineDAll of the above
单选题Oil water separators are used to ensure that ships don’t discharge oil when () bilge water.Ato pump offBbeing pumpedCpumping outDit pumping out