单选题An emergency bilge pumping system is provided and should be () of the main bilge pumping system, according to the SOLAS 74 Convention.AdependentBin dependentCin seriesDin parallel
单选题
An emergency bilge pumping system is provided and should be () of the main bilge pumping system, according to the SOLAS 74 Convention.
A
dependent
B
in dependent
C
in series
D
in parallel
参考解析
解析:
暂无解析
相关考题:
When the ships is going to enter into the harborA.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest form high level one to lower level oneD.test emergency generator
Aboard damaged vessels, the MOST important consideration is preserving ______.A.bilge pumping capacityB.reserve buoyancyC.level attitudeD.Instability
单选题Where tanks are arranged for either oil or ballast, () must be fitted in the pipeline.Aa change-over chestBa head tankCa emergency bilge pumpDan air cooler
单选题In the voyage, when carrying out abandon ship drill, should be test every time().Athe emergency lighting system for muster and abandon shipBair/oil emergency shut-downCM-Eemergency operationDmain/auxiliary steering gear changing
单选题The bilge pump on a fishing vessel().Amust be fixed if the vessel exceeds 12 meters in lengthBmay be used as a fire pumpCmust be portable if there are more than 4 watertight compartmentsDmust be capable of pumping at least 450 gpm
单选题The bilge system has been performing well; however, the aft starboard engine room bilgewell suddenly fails to be pumped outWhich of the following should be done first to determine the cause?()AOpen the bilge pump for inspectionBRemove each of the manifold valvesCRemove only the manifold valve to the affected bilge-wellDAttempt to pump out another bilge well to determine if the entire system is affected
单选题You are unable to pump out the aft starboard engine room bilge well that is fouled, with one foot of water over the top of the bilge well, what action should be carried out?()ASend the wiper into the well with only a scoop and pailBRemove the bilge manifold valve and attempt to back flush the lineCSimultaneously operate all available bilge pumpsDIt is only necessary to transfer half the contents of a drum of degreaser into the bilge well
单选题Which of the following is NOT true according to the passage?()ABoth the main steering gear and the auxiliary steering gear should be operatedBThe alarms fitted to the remote control system should be operatedCThe emergency generator compartment should be checkedDThe communication system between the bridge and the steering gear compartment should be operated
单选题An emergency diesel generator should automatically shut down in the event of ()Adangerous over-speedingBa loss of lube oil pressureCactivation of the fixed CO2 system for the emergency generator spaceDall of the above
单选题The emergency bilge suction or bilge () is used to prevent flooding of the ship.Ainjection valveBrelief valveCdischarge valveDinlet filter
单选题The emergency bilge suction or bilge injection valve is used to prevent () of the ship.AproceedingBoverloadingCcollisionDflooding
单选题During the PSC inspection, under the provisions of SOLAS 74, which one may not be regarded as clear grounds for ships’ detainment?()Afailure of the proper operation of emergency generatorBinsulation of piping including exhaust pipes in engine room contaminated by oilCimproper operation of bilge of bilge of bilge pumping arrangementsDdamaged sanitary pump
单选题The fire pumps must be capable of delivering a total quantity of water at a defined head, not less than () of the total bilge pumping capacity.Aone-thirdBtwo-thirdsCone-fourthDtwo-fourths
单选题The SOLAS convention about “passenger ship and dried food ship damage control” prescribes that the engine room emergency bilge water suction should connect with ()Athe main S-W pumpBballast pumpCair-conditioning water pumpDthe main S-W pump or ballast pumps that have the biggest output
单选题In the voyage, when carrying out abandon ship drill () should be test every time.Athe emergency lighting system for muster and abandon shipBair oil emergency shut-downCME emergency operationDmain auxiliary steering gear changing
单选题According to the SOLAS convention, the bilge water system ()Amust connect the bilge well suction directlyBshould not pump out the water accumulated in the cargosCshould not used for emergency drainage in case of ship collisionDshould connect to the fire fighting system directly
单选题When installed for bilge pumping or ballast duty, centrifugal pumps require a () to remove air from the suction pipe.Aair chamberBhead lankCprimerDprime mover
单选题If one of the bilge system manifold valves does not properly seat, the ()Abilge well connected to that valve, plus the second bilge well being pumped will be completely emptiedBbilge system will lose vacuum and prevent the other bilges from being pumped outCbilge well aft connected to that valve will siphon its contents to the forward bilge wellsDdischarge pressure will be too high
单选题Oil water separators are used to ensure that ships don’t discharge oil when () bilge water.Ato pump offBbeing pumpedCpumping outDit pumping out
单选题During the PSC inspection, under the provisions of SOLAS 74, which one may not be regarded as clear grounds for ships’ detainment?()Aexcess amount of oily-water mixtures in bilgesBinsulation of piping including exhaust pipes in engine room contaminated by oilCimproper operation of bilge pumping arrangementsDthere were an actual emergency
单选题The emergency bilge suction valve is typically used ().Ato inject cleaning additives when the bilges are extremely dirtyBwhen the main condenser becomes fouled, in order to provide additional cooling water circulationCto connect the rose box to the independent bilge suctionDif the bilges become flooded and they can not be emptied by any other means
单选题With reference to operating a four-ram steering gear system under emergency conditions, which one of the following statements is incorrect?()AOnly one pump should be used at any timeBThe ship speed should be reduced to 70% of the normalCWatch keeping of the steering gear should be increasedDLimitations of the steering gear should be logged but the bridge need not be informed
单选题If water is rising in the bilge of a lifeboat,you should FIRST().Aabandon the survival craftBcheck for cracks in the hullCshift all personnel to the sternDcheck the bilge drain plug
单选题On offshore drilling units,emergency lighting and each emergency power system must be tested at least once a().AdayBweekCmonthDyear