单选题Oxygen corrosion in auxiliary boilers is prevented by treating the boiler feed tank with either sodium ()Asulfite or hydrazineBsulfite or hygroscopic sulfiteCbromide or hydrazineDbromide or hygroscopic sulfite
单选题
Oxygen corrosion in auxiliary boilers is prevented by treating the boiler feed tank with either sodium ()
A
sulfite or hydrazine
B
sulfite or hygroscopic sulfite
C
bromide or hydrazine
D
bromide or hygroscopic sulfite
参考解析
解析:
暂无解析
相关考题:
If an auxiliary diesel engine coolant temperature is higher than normal, but the thermostat is determined not to be defective, you would suspect a/anA.cavitation erosion in the water jacketsB.excess corrosion inhibitor in the coolantC.dirty jacket water coolerD.defective turbocharger
When anaerobic bacteria convert the sewage to an inert sludge, .A.no oxygen is neededB.oxygen is necessaryC.oxygen is given offD.no gas is produced
The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness
A bypass line provided around a waste heat auxiliary boiler in a diesel engine exhaust system, may be used to avoid boiler ______.A.corrosion at low engine loadsB.erosion at high engine loadsC.overload at high engine loadsD.scaling at all exhaust temperatures
Chafing gear ______.A.reduces and prevents corrosion of standing riggingB.prevents corrosion of running riggingC.reduces and prevents wear caused by the rubbing of one object against anotherD.protects the body against extreme cold
Deficient oxygen content inside a chain locker can be detected with ______.A.litmus paperB.a combustible gas indicatorC.an oxygen breathing apparatusD.an oxygen indicator
单选题The concentration of total dissolved solids in the water of an auxiliary boiler can increase as a result of ().Aseawater contaminationBfrequent surface blowsCdissolved oxygen deaerationDfrequent bottom blows
单选题The spread of fire is NOT prevented by().Ashutting off the oxygen supplyBcooling surfaces adjacent to the fireCremoving combustibles from the endangered areaDremoving smoke and toxic gases by ensuring adequate ventilation
单选题The diesel engine exhaust gas bypass, as fitted with some waste heat boilers, is installed to ()Aprevent engine back pressure at heavy loadsBincrease total engine efficiency at low loadsCprevent boiler corrosion at low engine loadsDimprove engine fuel consumption at any load
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().Aoperating the boiler at less than normal water levelBinstalling fins on the firesides of water-tubesCincreasing the amount of excess air to the burnersDtreating the boiler water with chemical oxygen scavengers
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Aremove suspended and precipitated solids from the boiler waterBcompletely drain the boiler in an emergency situationCprevent hardened scale deposits in the water drumDremove floating impurities from the oily water surface
单选题Which command would correctly start a TSPITR of the USERS tablespace?()A recover tablespace users until time ,,10/06/2008:22:42:00 auxiliary ,,c/oracle/auxiliaryB recover tablespace users time ,,10/06/2008:22:42:00 auxiliary destination ,,c:/oracle/auxiliary; time ,, 10/06/2008:22:42:00 auxiliary destination ,,c/oracle/auxiliaryC recover tablespace users to point-in.D recover tablespace users except time ,,10/06/2008:22:42:00 auxiliary destination ,,c:/oracle/auxiliaryE recover tablespace users until time ,,10/06/2008:22:42:00 auxiliary destination ,,c:/oracle/auxiliary
单选题Chafing gear().Areduces and prevents corrosion of standing riggingBprevents corrosion of running riggingCreduces and prevents wear caused by the rubbing of one object against anotherDprotects the body against extreme cold
单选题Deficient oxygen content inside a chain locker can be detected with().Alitmus paperBa combustible gas indicatorCan oxygen breathing apparatusDan oxygen indicator
单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()AHigh oxygen concentrationBLow pHCProper alkalinityDAll of the above
单选题If an auxiliary diesel engine temperature is higher than normal ,but the thermostat is determined not to be defective you would suspect a /an ()Acavitation erosion in the water jacketsBexcess corrosion inhibitor in the coolantCdirty jacket water coolerDdefective turbocharger
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()Aprecipitate silica from solutionBreduce corrosion in the heating coilCprevent clogging and erosion in the coilDmaintain zero water hardness
单选题The procedures recommended for auxiliary boilers having high salinity include ().Atreating with oxygen scavengersBsecuring the boiler and giving it a blowing downCincreasing the pHDreducing the phosphate level
单选题Auxiliary boilers can be classified as()Awater-tube natural circulation boilersBfire-tube boilersCwater-tube forced circulation boilersDall of the above
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Acompletely drain the boiler in an emergencyBprevent sludge from forming in the drumCremove floating impurities from the boiler water surfaceDremove settled solids from the water drum
单选题Auxiliary boilers are divided into several classifications, one of which is()Afire-tube controlled circulationBfire-tube supercritical circulationCwater-tube natural circulationDwater-tube express circulation
单选题Who is in charge of the auxiliary boilers?()AThe chief engineerBThe second engineerCThe third engineerDThe fourth engineer
单选题The spread of fire is prevented by().Acooling surfaces adjacent to the fireBleaving combustibles in the endangered areaCincreasing the oxygen supplyDAll of the above