单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()Aair or water in the furnaceBcombustion pulsesCfuel oil pump failureDflame failure

单选题
Excessive vibration of an automatically fired auxiliary boiler can be caused by ()
A

air or water in the furnace

B

combustion pulses

C

fuel oil pump failure

D

flame failure


参考解析

解析: 暂无解析

相关考题:

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

Which of the following problems is the main source of fuel pump and injection system malfunctions?A.Improper lubricationB.Air in the fuel systemC.Coated fuel linesD.Excessive vibration

The major cause of fuel pump and injection system problems is _____.A.improper adjustmentsB.contaminated fuelC.kinked fuel linesD.excessive engine vibration

A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

温煮的英文是Boil。

The Database Resource Manager is automatically enabled in the maintenance window that runs the Automated Maintenance Task. What is the reason for this?()  A、 to prevent the creation of an excessive number of scheduler job classesB、 to allow the Automated Maintenance Tasks to use system resources without any restrictionC、 to allow resource sharing only among the Automated Maintenance Tasks in the maintenance windowD、 to prevent the Automated Maintenance Tasks from consuming excessive amounts of system resources

When youre performing a tablespace point-in-time recovery, which tablespaces will always be restored to the auxiliary instance?()A、 The SYSTEM tablespace.B、 The UNDO tablespace.C、 All tablespaces with tables.D、 All tablespaces with indexes.E、 No tablespaces are automatically restored.

下面代码执行后,正确的输出结果是()。A、You are fired! You are hired!B、You are fired! You are fired!C、You are hired! You are hired!D、You are hired! Youarefired!

焗的英文是()。A、RoastB、BakeC、StewD、Boil

单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum

单选题Excessive vibration in an operating diesel generator may be caused by ()Aelectrical overloadBsurging at governed RPMCloose engine mounting boltsDcoolant leaking into the cylinder

单选题In the event of failure of an auxiliary such as a lubricating pump, the standby pump is started and put on the line automatically“the line” in this sentence refers to()Afuel manifoldBlubricating pipe lineCauxiliary engine pipe lineDgenerator output line

单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()Afiring for extended periods in the low fire modeBoverheating, due to waterside depositsCvarying the water level above the crown sheetDcarrying excessive alkalinity in the boiler water

单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()Acool the furnace to prevent pre-ignitionBremove explosive vapors from the furnaceCevaporate accumulated unburned fuel oilDprovide sufficient air in the furnace to allow ignition of the fuel

单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()Asalinity is abnormally highBsteam demand is too highCwater level is abnormally lowDfeedwater flow is low

单选题Excessive valve lash in an auxiliary diesel engine will cause the valves to open()Alater and close soonerBsooner and close laterCsooner and close soonerDlater and close later

单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()Aexcessive purging before lighting offBinsufficient trail for ignition periodCa faulty transformer in the ignition circuitDinsufficient purging before lighting off

单选题Which of the terms listed below represents the operational speed at which excessive engine vibration is created?()ANon-harmonic speedBCritical speedCMaximum speedDDesign maximum speed

单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().Aair supply is shut offBfuel supply is shut offCwater supply is shut offDsafety valve lifts

单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()Aa burned out solenoid in the oil supply valveBhigh temperature excess airCincorrectly setting the hot-well dump valveDan incorrectly positioned burner snubber realy

单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure

多选题When youre performing a tablespace point-in-time recovery, which tablespaces will always be restored to the auxiliary instance?()AThe SYSTEM tablespace.BThe UNDO tablespace.CAll tablespaces with tables.DAll tablespaces with indexes.ENo tablespaces are automatically restored.

单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces

单选题The Database Resource Manager is automatically enabled in the maintenance window that runs the Automated Maintenance Task. What is the reason for this?()A to prevent the creation of an excessive number of scheduler job classesB to allow the Automated Maintenance Tasks to use system resources without any restrictionC to allow resource sharing only among the Automated Maintenance Tasks in the maintenance windowD to prevent the Automated Maintenance Tasks from consuming excessive amounts of system resources

单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()Aincorrect electrode settingBincorrect nozzle positionCclogged fuel nozzleDbroken high tension lead

单选题An electrically driven automatically operating auxiliary blower is provided for slow speed and () of a low speed diesel engine.Amanoeuvring operationsBbad combustionCcoolingDmooring trial

单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().Acheck and regulate the water levelBclose the air cock once fires are litCblowdown the gage glassDcrack the steam stop to assure protective steam flow