单选题Which of the following conditions could cause the feed pump for an auxiliary boiler to lose suction?()AIncreased suction head pressureBDecreased feedwater temperatureCPump recirculating line being open too muchDExcessive feedwater temperature

单选题
Which of the following conditions could cause the feed pump for an auxiliary boiler to lose suction?()
A

Increased suction head pressure

B

Decreased feedwater temperature

C

Pump recirculating line being open too much

D

Excessive feedwater temperature


参考解析

解析: 暂无解析

相关考题:

In which of the following topologies could the failure of one machine cause the entire network tostop functioning?() A. MeshB. Token ringC. StarD. Spanning tree

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

Which of the listed problems could produce a high absolute pressure within a flash type evaporator?A.production of high salinity distillateB.seawater feed temperature below 165℃C.a leak in the first stage demisterD.a cracked distillate pump vent line

Which of the following components could MOST likely cause Mike, a technician, to receive a ‘Nonsystem disk or disk error’ after POST?()A、Bad memoryB、Video cardC、Faulty chipsetD、FDD

In which of the following topologies could the failure of one machine cause the entire network tostop functioning?()A、MeshB、Token ringC、StarD、Spanning tree

Which of the following could cause an Inaccessible boot drive error during the boot process? ()A、HDD failureB、DVI failureC、USB failureD、CD failure

Several users report that they are unable to print to a new printer recently installed. The technician is unable to ping the printer. Which of the following is the MOST likely cause?()A、No IP address on the printerB、Paper jam in the paper feed trayC、Improper DNS settings on the printerD、Broken LCD screen on the printer

Which of the following could cause an NTLDR error on reboot?()A、Processor is failingB、Services failed to start on bootupC、RAM is faultyD、Boot.ini file is corrupt

单选题If a centrifugal pump vibrates and is noisy when operating, the cause could be ().Aworn gland sealing shaftBworn wearing ringsCa bent shaftDreversed pump coupling

单选题Which of the listed problems could produce a high absolute pressure within a flash type evaporator?()AProduction of high salinity distillateBSeawater feed temperature below 165℃CA leak in the first stage demisterDA cracked distillate pump vent line

单选题Which of the following conditions could contribute to the cracking of a diesel engine cylinder head?()ALeaking seal ringBInsufficient heat transfer from the exhaust valvesCBlock cooling water passages to the headDExcessive scavenging air provided to the engine

单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow

单选题Which of the conditions listed could cause the cylinder relief valves on a large, low-speed, propulsion diesel engine to lift?()APlugged injector nozzlesBExcessive fuel injectionCVery late injection timingDIncorrect crankshaft clearance

单选题Which of the following conditions can cause excessive lube oil consumption in a diesel engine?()ALow lube oil temperatureBDirty lube oil strainerCLow lube oil pressureDHigh lube oil temperature

单选题Which of the following is true about coral reefs?AThey play a significant role in biodiversity.BThey account for 25% of the marine life.CMore than a quarter of marine life feed on them.DThey are threatened by marine life and could be killed.

单选题Which of the following conditions could be a cause of excessive fuel dilution of diesel engine lube oil?()ALeaking fuel injectorsBLower than normal compressionCDelayed fuel injectionDAll of the above are correct

单选题When the tilting box of a variable stroke axial-piston pump is perpendicular to the pump shaft, which of the following conditions will exist?()AThe pistons reciprocateBThe ‘B’ end cylinder barrel rotatesCThere is no fluid flowDPower is transmitted hydraulically

单选题Increasing the speed of a rotary pump above its rated speed will result in which of the following conditions to occur?()ALoss of suctionBIncreased clearancesCDecreased clearanceDDecreased slippage

单选题Which of the listed conditions will cause the feed water that has not flashed to vapor in the first-stage of a flash evaporator, to flow into the second-stage?()AGravity siphon effectBHigher vacuum in the second-stageCDifference in brine density between first and second stagesDlower pressure in first-stage

单选题Which of the following conditions can cause below normal air pressure in the intake manifold of a turbocharged diesel engine?()AExcessive piston blow-by to the manifoldBInsufficient cooling water flowCAccumulated water in the air boxesDClogged air intake filters

单选题Several users report that they are unable to print to a new printer recently installed. The technician is unable to ping the printer. Which of the following is the MOST likely cause?()ANo IP address on the printerBPaper jam in the paper feed trayCImproper DNS settings on the printerDBroken LCD screen on the printer

单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure

单选题If an operating bilge pump is developing good vacuum, but is unable to discharge any water, which of the following problems is the most probable cause?()AThe wearing rings are excessively wornBThe suction strainer is cloggedCThe discharge valve is cloggedDThe shaft is worn

单选题Which of the following conditions would cause carbon deposits to form in the piston ring belt of a diesel engine?()Afaulty combustionBexcessive ring temperatureCover lubricationDall of the above

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity

单选题Which of the following actions should be taken if during a routine maintenance inspection of a centrifugal pump, localized scoring on a pump shaft sleeve is detected?()ACorrect the cause of the scoring and repair the sleeve or replace with a new oneBReassemble the unit and provide more water leak off for proper lubricationCCheck for parallel alignment of the sleeve radial faces to the sleeve boresDReassemble the unit and adjust the governor to obtain a slower speed

单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().Aa low load on the unitBa clogged pump suction strainerCa blockage in the line between the pump and hydraulic motorDthe hydraulic motor turning too fast