单选题In the refrigeration system, a shortage of refrigerant is indicated by ().Athe compressor short cycling on high pressure cut out switchBhigh suction pressureChigh head pressureDbubbles in the sight glass

单选题
In the refrigeration system, a shortage of refrigerant is indicated by ().
A

the compressor short cycling on high pressure cut out switch

B

high suction pressure

C

high head pressure

D

bubbles in the sight glass


参考解析

解析: 暂无解析

相关考题:

Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题A refrigerant boils and vaporizes in the () in a compression refrigeration system.Aliquid receiverBcompressorCcondenserDcooling coil

单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().Aa shortage of refrigerant in the systemBair in the systemCan accumulation of liquid refrigerant in the crankcaseDa shortage of oil in the crankcase

单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()AShortage of refrigerant oilBSlight shortage of refrigerantCExcessive condenser cooling water flowDFaulty expansion valve

单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().Arestriction in refrigerant pipingBair and non-condensable gases in the condenserCwater in the refrigerantDflooding back of liquid refrigerant from the evaporator

单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator

单选题If a refrigeration system were short of refrigerant, the condition would result in ().Acontinuous running of the compressorBhigh suction pressureChigh discharge pressureDshort cycling of the compressor on the water failure switch

单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().Amaintain adequate coil back pressureBprohibit flashing in the liquid lineCreduce refrigerant volume in the systemDreduce compressor discharge line loading

单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().Atoo much refrigerant in the systemBoil entrained in the refrigerantCless than a full charge of refrigerant in the systemDice crystals forming in the refrigerant

单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().Aa shortage of compressor oilBwarm food in the refrigeratorCexcessive condenser cooling waterDa shortage of refrigerant

单选题Moisture is removed from a refrigeration system by().Ableeding refrigerant from the condenserBopening a drain petcock on the oil separatorCcondensing the water in the heat exchangerDusing a dehydrator cartridge

单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().Apassing it through the expansion valveBcondensing refrigerant in the system condenserCpassing the gaseous refrigerant through the heat interchanger on the suction side of the compressorDmaintaining a high pressure on the systems receiver

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题In which of the listed refrigeration system components does superheating of the refrigerant take place?()AExpansion valveBEvaporatorCDrierDReceiver

单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator

单选题Saltwater is typically provided to a refrigeration system to ().Acool the expansion valveBprevent refrigerant superheatingCcondense the refrigerant gasDprevent motor overheating

单选题Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()ASub-cooled liquidBSub-cooled vaporCSuperheated vaporDLiquid

单选题Crankcase sweating in a refrigeration system is caused by ().Aa stuck solenoid valveBa shortage of refrigerantCtoo much oil in circulationDtoo much superheat

单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().Asub-cooled liquidBhigh temperature liquidCoil saturated liquidDsuperheated vapor

单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().AliquidBdry saturated gasCwet saturated gasDsuperheated vapor

单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system

单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor