单选题Crankcase sweating in a refrigeration system is caused by ().Aa stuck solenoid valveBa shortage of refrigerantCtoo much oil in circulationDtoo much superheat

单选题
Crankcase sweating in a refrigeration system is caused by ().
A

a stuck solenoid valve

B

a shortage of refrigerant

C

too much oil in circulation

D

too much superheat


参考解析

解析: 暂无解析

相关考题:

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().Aa shortage of refrigerant in the systemBair in the systemCan accumulation of liquid refrigerant in the crankcaseDa shortage of oil in the crankcase

单选题Refrigeration system compressor crankcase sweating is an indication of ().Ainsufficient lube oil circulating through the systemBexcessive circulation of lube oil through the systemCinsufficient refrigerant in the systemDan overworked compressor

单选题If a refrigeration system compressor crankcase is sweating, you should ().Aadd refrigerant to the systemBadjust the thermal expansion valve to the proper settingCadjust the float valve to the proper holding pressureDopen the hand expansion valve

单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().Arestriction in refrigerant pipingBair and non-condensable gases in the condenserCwater in the refrigerantDflooding back of liquid refrigerant from the evaporator

单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().Aoverheated compressor bearingsBexcess lube oil viscosityCcarbon deposits on the compressor piston ringsDwax crystals forming in the lubricant

单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator

单选题When it is necessary to open a refrigeration system for repairs and the system will be open for more than a few minutes, the open ends of the system should be ().AdehydratedBpurgedCpluggedDevacuated

单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.AfilterBfilter drierCheat exchangerDair cooler

单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().Asystem was overcharged with refrigerantBsystem was low on refrigerantCsuction valves were leaking slightlyDrelief valve was leaking slightly

单选题In a refrigeration system, foaming of the crankcase oil may cause the ().Aexpansion valve to overfeedBcompressor to knockCwater regulating valve to failDcrankcase drains to plug

单选题Zinc rods are installed in the refrigeration system ().Aliquid strainerBliquid receiverCsaltwater condenserDevaporator

单选题Noise in a refrigeration compressor can be caused by ().Aworn bearings and piston pinsBslugging due to flooding backCtoo much oil in circulationDAll of the above

单选题Diesel engine ‘blow-by’ into the crankcase is caused by excessive ring()Aback clearanceBside clearanceCgap clearanceDtaper clearance

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().Arefrigerant boiling out of solution from the lube oilBliquid refrigerant flooding the compressor and systemClube oil viscosity being reduced by refrigerant dilutionDcompressor suction pressure suddenly increasing

单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator

单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().Acompressor damage from improper lubricationBrefrigerant absorption by the lubricantCincreased viscosity in the lubricantDcarbon deposit on the compressor suction valves

单选题In the () refrigeration compressor one end of the crank shaft extends through the crankcase house for connection, via a coupling or pulley, to an external drive motor.Aopen-typeBhermeticCsemi-hermeticDall the above

单选题The accumulation of air and other non-condensable gases in a refrigeration system will ().Acause a loss of the liquid sealBcreate a vapor lock in the liquid receiverCcollect in the condenserDcause foaming of the oil in the crankcase

单选题Moisture in a refrigeration system can cause ().Afreezing the expansion valve closedBcorrosion of system pipingCimproper temperature regulationDall of the above

单选题A diesel engine crankcase ventilation system ()Aprevents spark generationBremoves combustible gasesCdetermines the level of combustible gasesDprovides inert gas generation in crankcase

单选题Sweating of the refrigeration system compressor crankcase is caused by ().Atoo much superheatBinsufficient superheatCsuction pressure too lowDexcessive refrigerant returning to the compressor

单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor

单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.Ahas continuously for a long periodBsuction pressure is below normalCoil level is below normalDstarts after a long idle period