单选题The furnace of an oil fired boiler should be () before the operating burner is lit.Afilled with waterBpurgedCcleared of airDNone of the above is true
单选题
The furnace of an oil fired boiler should be () before the operating burner is lit.
A
filled with water
B
purged
C
cleared of air
D
None of the above is true
参考解析
解析:
暂无解析
相关考题:
In a()boiler the hot gases from the furnace pass gases from the furnace pass water is on the outside. A.water-tubeB.fire-tubeC.exhaust gasD.composite
When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply
A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off
单选题Before starting a diesel engine, you should always()Acheck the pyrometer readingsBcheck the crankcase oil levelCcheck the fuel oil strainersDclean the fuel system
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum
单选题You should frequently compare drum-mounted and remote-reading water level indicators() between these have contributed to failures because of overheating through shortage of water, when a boiler was being oil-fired.AdescriptionsBdiscrepanciesCdifferentDdeflections
单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().Ayellowish flameBgolden yellow flameCwhite flameDbrilliant white flame
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished
单选题Before starting a diesel engine that has an engine driven lube oil pump, the engineer should ().Aopen the bypass lineBcut in the lube oil coolerCpressurize the lube oil systemDtop off the expansion tank
单选题When an auxiliary boiler is panting and emitting black smoke, you should ().Aincrease the fuel oil temperatureBdecrease the fuel oil temperatureCdecrease the fuel oil supply pressureDincrease the air supply
单选题The forced draught fan should be started and air passed through the furnace for several minutes to “()” it of any exhaust gas or oil vapors.AblowBcleanCscavengeDpurge
单选题Diesel engine waste heat boiler construction is usually of the fire-tube or()Acyclone furnace boiler typeBdry back boiler typeCwater-tube typeDcritical circulation boiler type
单选题A dazzling white burner flame in the boiler furnace indicates ().Aproper combustionBwater in the fuelCexcess airDcold fuel oil
单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()Acool the furnace to prevent pre-ignitionBremove explosive vapors from the furnaceCevaporate accumulated unburned fuel oilDprovide sufficient air in the furnace to allow ignition of the fuel
单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()Aexcessive purging before lighting offBinsufficient trail for ignition periodCa faulty transformer in the ignition circuitDinsufficient purging before lighting off
单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()Aair or water in the furnaceBcombustion pulsesCfuel oil pump failureDflame failure
单选题If in doubt as to the true water level when a boiler is being oil-fired, you should ().Atake no measuresBextinguish the fire as soon as possibleCfeed water to the boilerDopen the blow down valve
单选题() should be tested and adjusted when the boiler survey is carried out.AThe boiler oil tankBThe steam pipeCThe fire sideDThe safety valves
单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()Aa burned out solenoid in the oil supply valveBhigh temperature excess airCincorrectly setting the hot-well dump valveDan incorrectly positioned burner snubber realy
单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure
单选题One engine manufacturer recommends heavy fuel oil should not be heated above 80℃ to 95℃ (176 ℉ TO 203℉) before purificationThis upper limit should be observed to ensure against()Aflattening of the bowl neoprene O-ringsBoperation within the explosive rang of the fuelCexcessive purifier operating pressuresDexcessive oil viscosity
单选题One of the main purposes of refractories in a boiler furnace is to()Ahelp preheat the air for the furnacesBhelp preheat the feedwaterCprotect economizer from excessive heatDprevent excessive furnace heat losses
单选题As for an oil-fired boiler if at a normal steaming condition and water goes out of sight in gauge glasses the action you should take is: () (1) secure oil to fires (2) increase feed pump pressureA(1)B(1)and(2)C(2)Dneither(1)nor(2)
单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().Acheck and regulate the water levelBclose the air cock once fires are litCblowdown the gage glassDcrack the steam stop to assure protective steam flow
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A10B7C4D1
单选题Which action should be taken when an auxiliary boiler in is operation?()AClean all electrical connectionsBLift the relief valves by handCInspect and clean all solenoid valvesDInspect for oil and water leaks
单选题A dazzling white burner flame in the boiler furnace indicates ().Ano combustionBdeposits in the fuelCexcessive air in the fuelDcold fuel oil