单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat

单选题
One cause of high head pressure occurring in a refrigeration system can be ().
A

insufficient cooling water flow to the condenser

B

a low refrigerant charge in the system

C

the liquid valve is open too much

D

high evaporator superheat


参考解析

解析: 暂无解析

相关考题:

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题Which of the following problems represent one possible cause of high lube oil consumption in a four stroke diesel engine?()AWorn intake valve guidesBPitted pre-combustion chambersCLoose valve tappetsDHigh exhaust back pressure

单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().Acompressor;condenserBcondenser;evaporatorCthrottle valve;evaporatorDevaporator;condenser

单选题If a refrigeration compressor is short cycling on high head pressure, you should ().Apurge the condenser if the waterside is dirtyBcheck for proper water flow through the condenserCincrease the high pressure cutout settingDreduce the cooling water flow

单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly

单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow

单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().Arun continuouslyBnot startChave high discharge pressureDshort cycle on the high pressure switch

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题In the refrigeration system, a shortage of refrigerant is indicated by ().Athe compressor short cycling on high pressure cut out switchBhigh suction pressureChigh head pressureDbubbles in the sight glass

单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题Which cause of following will not lead to refrigeration plant short-cycle?()Alack of refrigerantBrefrigerant with much waterCset defectively low pressure relayDno cooling water

单选题If the head pressure is too high,()Athe relief valve should open before the high-pressure cutoutBthe relief valve should open and let excess refrigerant go to receiverCthe high-pressure cutout switch should operate before the relief valve opensDclose in on the suction valve

单选题What separate the high pressure side from the low pressure side in a refrigeration system?()ACondenser and thermal expansion valveBKing and solenoid valvesCCompressor and thermal expansion valveDCondenser and solenoid valve

单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat

单选题In a compression refrigeration plant the hot, high pressure refrigerant gas is cooled by the sea water and becomes liquid in the ().AcompressorBcondenserCthrottle valveDevaporator

单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureAany of (1) and (3)Bany of (1) and (2)Cany of (2) and (3)Dany of (1), (2) and (3)

单选题An increase in the heat load to a refrigeration system will cause ().Athe suction pressure to decreaseBthe suction temperature to increaseCincreased ice formation on the evaporator coilDexcessive short cycling of the compressor

单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system

单选题In a refrigeration system, which of the following statements describes the actions occurring when a solenoid valves, used in conjunction with an unloader head is energized?()AThe solenoid valves directs high pressure gas to the valve lifting device raising the suction valve off its seat and causing one specific cylinder to become unloadedBThe solenoid valves directs high pressure gas to the underside of the unloading piston, causing it to rise and allowing the recirculating ports to be openedCWhen the solenoid valve becomes energized, the valve ports become closed, allowing discharge pressure to build up above the piston, shifting it and causing it to unloadDThe solenoid valve allows the refrigerant to pass from the suction chamber to the top of the unloader piston, causing the piston to lift and unload the cylinder

单选题If a compressor runs continuously, the cause might be a()Adefective thermal bulbBclogged scale trapCstuck high-pressure switchDstuck low-pressure switch