单选题If a refrigeration compressor is short cycling on high head pressure, you should ().Apurge the condenser if the waterside is dirtyBcheck for proper water flow through the condenserCincrease the high pressure cutout settingDreduce the cooling water flow

单选题
If a refrigeration compressor is short cycling on high head pressure, you should ().
A

purge the condenser if the waterside is dirty

B

check for proper water flow through the condenser

C

increase the high pressure cutout setting

D

reduce the cooling water flow


参考解析

解析: 暂无解析

相关考题:

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题An important consideration in selecting a lubricating oil for use in a refrigeration compressor is for the oil to ()Ahave a high viscosity indexBmix readily with refrigerantChave a high freezing pointDhave a low pour point

单选题Short cycling of a refrigeration compressor refers to ().Afrequently grounding outBfrequently starting and stoppingCrunning too fastDrunning too slow

单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly

单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().Asystem was overcharged with refrigerantBsystem was low on refrigerantCsuction valves were leaking slightlyDrelief valve was leaking slightly

单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow

单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().Arun continuouslyBnot startChave high discharge pressureDshort cycle on the high pressure switch

单选题()are supplied by main switchboard directly.ASuez Canal searchlight, air compressor and air conditioning compressorBAir compressor, boiler blower and refrigeration plantCBoiler blower, Suez Canal searchlight and refrigeration plantDSuez canal searchlight, air compressor and boiler blower

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题In the refrigeration system, a shortage of refrigerant is indicated by ().Athe compressor short cycling on high pressure cut out switchBhigh suction pressureChigh head pressureDbubbles in the sight glass

单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()Asystem is overcharged with refrigerantBsystem is low on refrigerantCdischarge valves are leaking excessivelyDdischarge valves are leaking slightly

单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat

单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureAany of (1) and (3)Bany of (1) and (2)Cany of (2) and (3)Dany of (1), (2) and (3)

单选题An increase in the heat load to a refrigeration system will cause ().Athe suction pressure to decreaseBthe suction temperature to increaseCincreased ice formation on the evaporator coilDexcessive short cycling of the compressor

单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system

单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()AThe condenser and the expansion valveBThe king valve and the solenoid valveCThe compressor and the expansion valveDThe condenser and the solenoid valve