单选题If a compressor runs continuously, the cause might be a()Adefective thermal bulbBclogged scale trapCstuck high-pressure switchDstuck low-pressure switch

单选题
If a compressor runs continuously, the cause might be a()
A

defective thermal bulb

B

clogged scale trap

C

stuck high-pressure switch

D

stuck low-pressure switch


参考解析

解析: 暂无解析

相关考题:

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressorA.has run continuously for a long periodB.suction pressure is below normalC.oil level is below normalD.starts after a long idle period

Badly leaking refrigeration compressor discharge valves will cause ______.A.overfeeding of the expansion valveB.damage to the condenserC.constant running of the compressorD.flooding of the receiver

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems

What is the most probable cause of reduced capacity in a reciprocating air compressor ________.A.Carbon on cylinder headsB.Faulty unloaderC.Leaking air valvesD.Plugged air cooler

单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()AShortage of refrigerant oilBSlight shortage of refrigerantCExcessive condenser cooling water flowDFaulty expansion valve

单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()AClosing of the solenoid valveBClosing of the expansion valveCAn increase in the suction pressureDDecreasing the suction pressure

单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly

单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().Asystem was overcharged with refrigerantBsystem was low on refrigerantCsuction valves were leaking slightlyDrelief valve was leaking slightly

单选题If the compressor runs continually, the cause might be the()Ahigh-pressure cutout switch is jammed openBlow-pressure switch is jammed shutCthermal bulb is not operating properlyDscale trap is clogged

单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()Atoo much cooling water going through the condenserBnot enough refrigerant in the systemCa leak in the evaporator coilsDno enough cooling water going through the condenser

单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().Aa shortage of compressor oilBwarm food in the refrigeratorCexcessive condenser cooling waterDa shortage of refrigerant

单选题Badly leaking refrigeration compressor discharge valves will cause().Aoverfeeding of the expansion valveBdamage to the condenserCconstant running of the compressorDflooding of the receiver

单选题A warmer than normal compressor suction line might be caused by ().Ainsufficient lubricationBinsufficient refrigerantCexcess refrigerantDexcessive opening of the expansion valve

单选题What is the result()?A  The program runs and prints “ I = 1 , j = 0”B  The program runs and prints “ I = 1 , j = 4”C  The program runs and prints “ I = 3 , j = 4”D  The program runs and prints “ I = 3 , j = 0”E  An error at line 4 cause compilation to fail.F  An error at line 7 cause compilation to fail.

单选题What is the result?()A  The program runs and prints nothing.B  The program runs and prints “Equal”.C  An error at line 5 cause compilation to fail.D  The program runs but aborts with an exception.

单选题Broken valve strips in an operating low pressure, air compressor will cause ().Aan immediate crankcase explosionBoil contamination in the compressed airCa decrease in compressor capacityDno immediate loss of the compressed air capacity

单选题If the electric motor driving an air compressor fails to start, the cause may be a ().Aleaking unloaderBtripped circuit breakerCcontrol line leakDdefective pop valve

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().Aoil foaming in the compressorBhigher than normal suction and discharge pressures with a higher box temperatureChigher than normal discharge pressure with a normal box temperatureDthe compressor to run continuously

单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().Acompressor damage from improper lubricationBrefrigerant absorption by the lubricantCincreased viscosity in the lubricantDcarbon deposit on the compressor suction valves

单选题An increase in the heat load to a refrigeration system will cause ().Athe suction pressure to decreaseBthe suction temperature to increaseCincreased ice formation on the evaporator coilDexcessive short cycling of the compressor

单选题If a reciprocating air compressor has a knock occurring in frequency with its operating RPM, the cause is probably ().Amisalignment or worn main bearingsBinsufficient cylinder lubricationCdefective or poorly fitted valvesDall of the above

单选题In the geography class, the teacher explained wind and water might cause soil()ApollutionBexcellenceCexplosionDerosion

单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.Ahas continuously for a long periodBsuction pressure is below normalCoil level is below normalDstarts after a long idle period