单选题If the discharge valve is closed before the drive motor is stopped, which of the following types of pumps will most likely be damaged?()ACentrifugalBGearCPropellerDTurbine

单选题
If the discharge valve is closed before the drive motor is stopped, which of the following types of pumps will most likely be damaged?()
A

Centrifugal

B

Gear

C

Propeller

D

Turbine


参考解析

解析: 暂无解析

相关考题:

To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid

The valve on the discharge side of a cargo pump on a tank vessel will usually be a ______.A.butterfly valveB.spectacle valveC.check valveD.globe valve

Before discharge of cargo tank ballast is undertaken,______.A.the deck isolating valve is openB.flue gas isolating valveC.blower suction valveD.blower discharge valve

To ensure proper seating when closing a valve on a tank,the valve should be ______.A.Set up as tight as possible by handB.Set up tight using a valve wrenchC.Closed,opened a half turn,and then closedD.Closed against the stop and the locking pin inserted

ENG VALVE CLOSED指哪个活门()A、HMVB、PRSOVC、HPSOVD、spar valve

操作完后,关掉电动机。()A、After operation, start the electric motor.B、Before operation, stop the electric motor.C、Before operation, start the electric motor.D、After operation, stop the electric motor.

The security team has implemented new guidelines on how to handle sensitive information storedon workstations based on a past incident involving information found on donated workstations.Which of the following should be completed by technicians before donating the workstations?()A、Install a new operating systemB、Delete users’ data before donationC、Write the drive with 1’s and 0’s three timesD、Delete all partitions of the hard drive

单选题In () pump a closed discharge valve will not cause excessive pressure to build up.AgearBvaneCscrewDcentrifugal

单选题If the pump for a hydraulic anchor windlass is overheating, the cause may be ().Aexcessive drive motor speedBexcessive pump discharge pressureCtoo low of a tilting box angleDinsufficient drive motor speed

单选题Petroleum cargo tanks should not be topped off at deck level when loading on a cold day because().Aa subsequent temperature rise will cause the cargo to overflowBair pockets may cause the cargo to bubble out of the ullage holeCthe increased viscosity of the product requires higher loading pressure which increases the chances of a spillDthe tank valve may be stiff and a spill will occur before the valve can be closed

单选题If an electric motor driven air compressor fails to start, it may be due to a ().Aleaking discharge valveBjammed suction valveCtripped overload relayDbroken discharge un-loader

单选题If a centrifugal bilge pump were continually operated with the discharge valve closed the ().Amotor overload would openBrelief valve would openCpump would eventually overheatDmotor would overheat

单选题What is a characteristic of all centrifugal cargo pumps? ()AThey are self-primingBDecreasing the speed of rotation will decrease the discharge pressureCOpening the discharge valve wider will increase the discharge pressureDAll of the above

单选题In () pumps a closed discharge valve will cause bursting discharge pressure.AcentrifugalBplungerCinjectorDwater

单选题Why is it important for fuel oil tanks not to be topped off at the inner bottom level when loading on a cold day?()AIncreased viscosity of the product needs higher loading pressure, which increases the chances of a spillBAir pockets may cause the fuel to bubble out of the ullage holeCThe temperature rise of the fuel will cause an overflowDFueling valve may become stuck closed and cause the fuel oil to spill before the valve can be opened

单选题Which of the listed statements is correct concerning the starting of centrifugal pumps?()AThey should always be started with the discharge valve closedBThey should always be started with the discharge valve openedCA priming pump is always required to flood the impeller suctionDThey should always be started with the sealing line valves closed

单选题A relief valve for a cargo pump is generally installed().Aafter the discharge valveBbetween the pump and discharge valveCafter the suction valveDbetween the pump and suction valve

单选题If a centrifugal pump were continually operated with the discharge valve closed, the ().Amotor controller overload would openBpump would eventually overheatCrelief valve would continuously cycle openDmotor would overheat

单选题The valve on the discharge side of a cargo pump on a tanker will usually be a().Abutterfly valveBspectacle valveCcheck valveDglobe valve

单选题One of the consequences in continuing to operate a centrifugal bilge pump with the discharge valve closed, is that the ().Amotor overload will openBrelief valve will openCpump will overheatDmotor will overheat

单选题The simplest method to use for determining if a centrifugal pump is operating as designed, is to ().Aclosely observe the pump discharge temperatureBclose off the discharge valve, and watch for a rise in pressureCmomentarily close off the suction valve, and watch for a rise in pressureDuse a clamp on ammeter and compare the readings to past records

单选题A centrifugal pump attempting to develop flow against a closed discharge valve has a/an ().Acapacity of 0%Befficiency of 100%Cinternal slippage of 0%Dshut off horsepower rating of 100%

单选题In a refrigeration system, which of the following statements describes the actions occurring when a solenoid valves, used in conjunction with an unloader head is energized?()AThe solenoid valves directs high pressure gas to the valve lifting device raising the suction valve off its seat and causing one specific cylinder to become unloadedBThe solenoid valves directs high pressure gas to the underside of the unloading piston, causing it to rise and allowing the recirculating ports to be openedCWhen the solenoid valve becomes energized, the valve ports become closed, allowing discharge pressure to build up above the piston, shifting it and causing it to unloadDThe solenoid valve allows the refrigerant to pass from the suction chamber to the top of the unloader piston, causing the piston to lift and unload the cylinder

单选题The major difference between the discharge and suction valves installed in most low pressure, reciprocating air compressors is that()Aone valve seats upwards, while the other seats downwardsBthe reed valves used on the discharge are made substantially thicker and heavier than the suction valvesCthe suction valve springs exert a greater tension than the discharge valve springsDthe discharge valve springs exert a greater tension than the suction valve springs

单选题If the discharge valve is closed before the drive motor is stopped, which of the following types of pumps will most likely be damaged?()ACentrifugalBGearCPropellerDTurbine

单选题In slow speed two-stroke engines,()the fresh air entering begins when and stops as()Athe inlet port is opened by the up coming piston; the port is closed by the down goingBthe inlet valve is opened by the down going piston;the inlet valve is closedCthe inlet port is opened by the down going piston;the port is closed by the up comingDthe inlet valve is opened

单选题The valve on the discharge side of a cargo pump on a tank vessel will usually be a().Abutterfly valveBspectacle valveCcheck valveDglobe valve

单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().Aa low load on the unitBa clogged pump suction strainerCa blockage in the line between the pump and hydraulic motorDthe hydraulic motor turning too fast