单选题The valve on the discharge side of a cargo pump on a tanker will usually be a().Abutterfly valveBspectacle valveCcheck valveDglobe valve

单选题
The valve on the discharge side of a cargo pump on a tanker will usually be a().
A

butterfly valve

B

spectacle valve

C

check valve

D

globe valve


参考解析

解析: 暂无解析

相关考题:

To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid

The valve on the discharge side of a cargo pump on a tank vessel will usually be a ______.A.butterfly valveB.spectacle valveC.check valveD.globe valve

Which method should be used to warm up the pump turbines prior to discharge ________.A.Lock the turbine rotor and slowly bleed in steam until operating temperature is reachedB.Run the pump at high speed with the discharge valves closedC.Run the turbine at slow speed with the pump disconnectedD.Shut the discharge valve and run the pump at slow speed

Before discharge of cargo tank ballast is undertaken,______.A.the deck isolating valve is openB.flue gas isolating valveC.blower suction valveD.blower discharge valve

Cargo pump relief valves are piped to the ______.A.cargo pump pressure gaugesB.crossover lines interconnecting two pumpsC.suction side of pumpsD.atmosphere through pump vents

What is the purpose of the relief valve of a cargo pump ________.A.Provides for the removal of vaporsB.Allows two or more tanks to be filled at the same timeC.Provides for the emergency shutdown of the pumpD.Permits the return of cargo to the suction side of the pump

You start a centrifugal cargo pump to discharge cargo.The pump works for a while and then loses suction.This could be caused by ______.A.The pump running backwardsB.Incomplete primingC.The discharge head being too highD.All of the above

单选题Cargo pump relief valves are piped to the().Acargo pump pressure gaugesBcrossover lines interconnecting two pumpsCsuction side of pumpsDatmosphere through pump vents

单选题The discharge side of every fire pump must be equipped with a().Agate valveBpressure gaugeCcheck valveDstrainer

单选题What is a function of the wearing rings used in most centrifugal pumps?()AAbsorb erosion of high velocity discharge streamBSeal pump shaft against entry of airCIsolate the discharge side from the suction sideDDampen the turbulent discharge flow

单选题If a centrifugal bilge pump were continually operated with the discharge valve closed the ().Amotor overload would openBrelief valve would openCpump would eventually overheatDmotor would overheat

单选题What is a characteristic of all centrifugal cargo pumps? ()AThey are self-primingBDecreasing the speed of rotation will decrease the discharge pressureCOpening the discharge valve wider will increase the discharge pressureDAll of the above

单选题Which method should be used to warm up the pump turbines prior to discharge().ALock the turbine rotor and slowly bleed in steam until operating temperature is reachedBRun the pump at high speed with the discharge valves closedCRun the turbine at slow speed with the pump disconnectedDShut the discharge valve and run the pump at slow speed

单选题The usual symptoms of cavitation in a centrifugal pump is ().Anoise and vibrationBan increase in discharge pressureCan increase in suction pressureDlifting of the relief valve

单选题Your tanker is designed to carry anhydrous ammonia in bulk.The keel was laid in 1980.Which statement concerning the carriage of this cargo is TRUE().AA flammable gas detection system must be installed in each cargo pump roomBTanks may not be located on deckCCarriage of this cargo is authorized by issuance of an IMO CertificateDAluminum and copper alloys are prohibited from being in valve parts in contact with the cargo

单选题Which of the listed statements is correct concerning the starting of centrifugal pumps?()AThey should always be started with the discharge valve closedBThey should always be started with the discharge valve openedCA priming pump is always required to flood the impeller suctionDThey should always be started with the sealing line valves closed

单选题A relief valve for a cargo pump is generally installed().Aafter the discharge valveBbetween the pump and discharge valveCafter the suction valveDbetween the pump and suction valve

单选题An inert gas system installed on a tanker is designed to().Aaid in the stripping and cleaning of cargo tanksBincrease the rate of discharge of cargoCforce toxic and explosive fumes from a cargo tank to vent to the outside atmosphereDlower the oxygen levels inside cargo tanks,making explosion nearly impossible

单选题If a centrifugal pump were continually operated with the discharge valve closed, the ().Amotor controller overload would openBpump would eventually overheatCrelief valve would continuously cycle openDmotor would overheat

单选题When starting a centrifugal pump, the discharge valve should be ().AclosedBopened fullyCcracked openDpartly open

单选题The advantage of a centrifugal pump as compared with a reciprocating pump is that ().Adischarge is continuousBit has no internal valvesCupon accidental closing of discharge valve, excessive pressure will not build upDall of the above are true

单选题One of the consequences in continuing to operate a centrifugal bilge pump with the discharge valve closed, is that the ().Amotor overload will openBrelief valve will openCpump will overheatDmotor will overheat

单选题The simplest method to use for determining if a centrifugal pump is operating as designed, is to ().Aclosely observe the pump discharge temperatureBclose off the discharge valve, and watch for a rise in pressureCmomentarily close off the suction valve, and watch for a rise in pressureDuse a clamp on ammeter and compare the readings to past records

单选题What is the purpose of a relief valve?()Ato fill 2 tanks at the same timeBto use pump at a higher pressureCto return liquid to suction side if discharge valve is closedDAll of the above are true

单选题The combined fan discharge rate in an inert gas system is related to the().Ashoreside loading rateBmaximum cargo pump discharge rateCboiler forced draft fan rateDsize of the largest cargo tank

单选题The valve on the discharge side of a cargo pump on a tank vessel will usually be a().Abutterfly valveBspectacle valveCcheck valveDglobe valve

单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().Aa low load on the unitBa clogged pump suction strainerCa blockage in the line between the pump and hydraulic motorDthe hydraulic motor turning too fast