单选题In () pump a closed discharge valve will not cause excessive pressure to build up.AgearBvaneCscrewDcentrifugal

单选题
In () pump a closed discharge valve will not cause excessive pressure to build up.
A

gear

B

vane

C

screw

D

centrifugal


参考解析

解析: 暂无解析

相关考题:

If a centrifugal pump is driven by a constant speed electric motor and produces a discharge pressure less than designed, the cause is probably ______.A.excessive pump speedB.excessive suction headC.worn wearing ringsD.gross pump misalignment

The valve on the discharge side of a cargo pump on a tank vessel will usually be a ______.A.butterfly valveB.spectacle valveC.check valveD.globe valve

Which method should be used to warm up the pump turbines prior to discharge ________.A.Lock the turbine rotor and slowly bleed in steam until operating temperature is reachedB.Run the pump at high speed with the discharge valves closedC.Run the turbine at slow speed with the pump disconnectedD.Shut the discharge valve and run the pump at slow speed

单选题If a centrifugal bilge pump were continually operated with the discharge valve closed the ().Amotor overload would openBrelief valve would openCpump would eventually overheatDmotor would overheat

单选题If a hydraulic pump is overheating, the cause may be ().Aexcessive internal leakage in the pumpBlow discharge pressure and fluid flowCexcessive fluid level in the hydraulic reservoirDoperation of the pump at 100% efficiency

单选题Which of the following will be the advantage of a centrifugal pump as compared with a reciprocating pump?() (1) Its discharge is continuous (2) It has no internal valves (3) Upon accidental closing of discharge valve, excessive pressure will not build upA(1),(2)B(2),(3)C(1),(2),(3)D(2)only

单选题Which method should be used to warm up the pump turbines prior to discharge().ALock the turbine rotor and slowly bleed in steam until operating temperature is reachedBRun the pump at high speed with the discharge valves closedCRun the turbine at slow speed with the pump disconnectedDShut the discharge valve and run the pump at slow speed

单选题In () pumps a closed discharge valve will cause bursting discharge pressure.AcentrifugalBplungerCinjectorDwater

单选题If a refrigeration compressor will not start, the reason may be ().Athe pressure regulating valve is not closingBan excessive lack of refrigerant in the systemCbadly leaking discharge valvesDworn piston rings

单选题The usual symptoms of cavitation in a centrifugal pump is ().Anoise and vibrationBan increase in discharge pressureCan increase in suction pressureDlifting of the relief valve

单选题If a centrifugal pump is driven by a constant speed electric motor and produces a discharge pressure less than designed, the cause is probably().Aexcessive pump speedBexcessive suction headCworn wearing ringsDgross pump misalignment

单选题Which of the listed statements is correct concerning the starting of centrifugal pumps?()AThey should always be started with the discharge valve closedBThey should always be started with the discharge valve openedCA priming pump is always required to flood the impeller suctionDThey should always be started with the sealing line valves closed

单选题A relief valve for a cargo pump is generally installed().Aafter the discharge valveBbetween the pump and discharge valveCafter the suction valveDbetween the pump and suction valve

单选题Operating a rotary pump at speeds in excess of design requirements could cause().Adecreased clearances between rotating partsBdecreased slippage to the suction side of the pumpCair binding in the discharge portsDerosion and excessive wear

单选题If a centrifugal pump were continually operated with the discharge valve closed, the ().Amotor controller overload would openBpump would eventually overheatCrelief valve would continuously cycle openDmotor would overheat

单选题When starting a centrifugal pump, the discharge valve should be ().AclosedBopened fullyCcracked openDpartly open

单选题The advantage of a centrifugal pump as compared with a reciprocating pump is that ().Adischarge is continuousBit has no internal valvesCupon accidental closing of discharge valve, excessive pressure will not build upDall of the above are true

单选题The valve on the discharge side of a cargo pump on a tanker will usually be a().Abutterfly valveBspectacle valveCcheck valveDglobe valve

单选题One of the consequences in continuing to operate a centrifugal bilge pump with the discharge valve closed, is that the ().Amotor overload will openBrelief valve will openCpump will overheatDmotor will overheat

单选题The simplest method to use for determining if a centrifugal pump is operating as designed, is to ().Aclosely observe the pump discharge temperatureBclose off the discharge valve, and watch for a rise in pressureCmomentarily close off the suction valve, and watch for a rise in pressureDuse a clamp on ammeter and compare the readings to past records

单选题A centrifugal pump attempting to develop flow against a closed discharge valve has a/an ().Acapacity of 0%Befficiency of 100%Cinternal slippage of 0%Dshut off horsepower rating of 100%

单选题If the pump for a hydraulic anchor windlass is over heating, the cause may be ().Aincreased pump speedBexcessive pump discharge pressureCtoo low of a tilting box angleDlow pump speed

单选题If an operating bilge pump is developing good vacuum, but is unable to discharge any water, which of the following problems is the most probable cause?()AThe wearing rings are excessively wornBThe suction strainer is cloggedCThe discharge valve is cloggedDThe shaft is worn

单选题What is the purpose of a relief valve?()Ato fill 2 tanks at the same timeBto use pump at a higher pressureCto return liquid to suction side if discharge valve is closedDAll of the above are true

单选题If the discharge valve is closed before the drive motor is stopped, which of the following types of pumps will most likely be damaged?()ACentrifugalBGearCPropellerDTurbine

单选题The valve on the discharge side of a cargo pump on a tank vessel will usually be a().Abutterfly valveBspectacle valveCcheck valveDglobe valve

单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().Aa low load on the unitBa clogged pump suction strainerCa blockage in the line between the pump and hydraulic motorDthe hydraulic motor turning too fast