单选题The initial voltage of self-excitation generator set up by()Aresidual magnetismBvoltage regulatorCelectrical current for excitationDthe other running generator
单选题
The initial voltage of self-excitation generator set up by()
A
residual magnetism
B
voltage regulator
C
electrical current for excitation
D
the other running generator
参考解析
解析:
暂无解析
相关考题:
The generator voltages are usually stepped up to the transmission voltage level by ( ). A.series capacitorB.parallel reactorsC.step-up transformersD.step-down transformers
Overspeed of the diesel engine driving an electric generator could cause ______.A.low voltage tripB.reverse power tripC.damage to windingsD.excessive exhaust temperatures
She______everything else and concentrated on the task before her.A.set offB.set backC.set asideD.set up
The output voltage of a 440 volt, 60 hertz, AC generator is controlled by theA.prime mover speedB.exciter output voltageC.load on the alternatorD.number of poles
The headmaster wanted the classroom building__________as soon as possible.A.to set upB.to have been set upC.to be set upD.being set up
材料:The field current supply in older machines comes from a lower voltage direct current generator or exciter on the same shaft as the alternator. Modern machines however are either statically excited or of the high-speed brush-less type. The exciter is required to operate to counter the effects of power factor for a given load. The power factor is a measure of the phase difference between voltage and current and is expressed as the cosine of the phase angle. With a purely resistance load the voltage and the current are in phase, giving a power factor of one. The power consumed is therefore the product of voltage and current. Inductive or capacitive loads, combined with resistance loads, produce lagging or leading power factors which have a value less than one.The power consumed is therefore the product of current, voltage and power factor. The alternating current generator supplying a load has a voltage drop resulting from the load. When the load has a lagging power factor this voltage drop is considerable. Therefore the exciter, in maintaining the alternator voltage, must vary with load current and also the power factor. The speed change of the prime mover must also be taken into account.问题: The word “machines” in the passage refers to _____.A.the direct current generatorB.the alternating current generatorC.the exciterD.the prime moverWhich of the following statements is true according to the passage ?A.With a purely resistance load, the power factor is zeroB.Inductive loads combined with resistance loads produces leading power factorsC.Capacitive loads combined with resistance loads produces lagging power factorsD.With a purely resistance load, the phase angle is zeroWhen the load has a lagging power factor this voltage drop is considerable. This sentence means that _____.A.with a purely resistance load, the voltage drops too muchB.there is a considerable voltage drop in the capacitive load combined with resistance loadC.when the load is the capacitive load combined with resistance load, the voltage drops to zeroD.when the load is the inductive load combined with resistance load, the voltage drop is fairly largeThe exciter must vary with: ① load current ② the power factor, ③ speed change of the prime mover.A.①B.②C.①②D.①②③请帮忙给出每个问题的正确答案和分析,谢谢!
I second his motion that we( )a special board to examine.A.shall set upB.should set upC.will set upD.would set up
Which two statements about configuration an unconnected Catalyst Express 500 switch from setup mode using a PC are true?()A、You may use Cisco Network Assistant to set up the initial configurationB、You must use CLI for initial configurationC、You may use either CLI or CAN for configurationD、You may make a direct connection to the PC from any point on the switchE、You may only make a direct connection from the port with the flashing green LED to the PC
Which of the following SCSI signaling systems uses one return line for every outgoing line, is less susceptible to interference, signal degradation, crosstalk, and allows a cable length of up to 25 meters?()A、 SE (Single Ended)B、 DE (Double Ended)C、 LVD (Low Voltage Differential)D、 HVD (High Voltage Differential)
After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()A、 The power supply is not sufficient to power the server.B、 The voltage regulator module (VRM) was not installed.C、 The IRQ setting was not set.D、 The DMA setting was not set.
If a technician is traveling outside of the US, which of the following should be checked before setting up a workstation? ()A、Local file formatB、Wattage settingC、Local power codesD、Voltage setting
Which configuration option can be set either in the initial console menu or the Admin UI of the Infranet Controller? ()A、VLAN IDB、HostnameC、Domain nameD、Administrative timeout
单选题The voltage output of an AC generator is controlled by()Avarying the DC exciter voltageBvarying the reluctance of the air gapCregulating the speed of the prime moverDshorting out part of the armature windings
单选题The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ().AdroopBdropCdipDregulation
单选题Generators should have an excitation/voltage regulation system which will enable them to share the steady state reactive load () no machine exceeds its proportional share of reactive load by more than 10% of the rated reactive load of the largest generator.AwhenBso asCsuch thatDthough
单选题The power factor of an AC generator operating singularly is determined by the ()Aconnected loadBprime mover speedCfield excitationDgenerators rated voltage
单选题When securing an AC generator, you should FIRST ().Aopen the generator circuit breakerBswitch the voltage regulator to “manual”Cdecrease the field excitation to minimumDreduce the load on the unit
单选题After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()A The power supply is not sufficient to power the server.B The voltage regulator module (VRM) was not installed.C The IRQ setting was not set.D The DMA setting was not set.
单选题Self-excited a-cgenerator with "error operated" voltage control systems draw the full excitation power for the machine terminalsThis dispenses with the current transformers, reactors and capacitors necessary for accurate compounding, but renders the excitation system vulnerable to variations in its output voltageWhich of the following is correct about the generator mentioned according to the sentences above ().AIt consumes no excitation powerBIt has current transformersCComponents are needed for accurate compoundingDIts excitation system is vulnerable to voltage variations
单选题Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the ()Amanual positionBbus neutral positionCraise voltage positionDtransfer position
单选题()is used to control, modulate, monitor and protect generator set.AControl panelBLoad panelCParalleling panelDBusbar
单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().Ais smallBmay be neglectedCis usefulDis considerable
单选题The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the ().Aprime mover speedBexciter output voltageCload on the alternatorDnumber of poles
单选题The overspeeding of the diesel engine driving an electric generator could cause ().Alow voltage trip to tripBreverse power trip to tripCdamage to windingsDexcessive exhaust temperatures
单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()Aslightly less than the oncoming generator frequencyBthe same as the bus frequencyCslightly greater than the bus frequencyDthe same as the bus voltage
单选题The voltage developed by an AC generator is controlled by varying the ()Aspeed of the prime moverBAC excitation to the fieldCDC excitation to the fieldDDC excitation of the voltage regulator