单选题Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the ()Amanual positionBbus neutral positionCraise voltage positionDtransfer position
单选题
Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the ()
A
manual position
B
bus neutral position
C
raise voltage position
D
transfer position
参考解析
解析:
暂无解析
相关考题:
The generator voltages are usually stepped up to the transmission voltage level by ( ). A.series capacitorB.parallel reactorsC.step-up transformersD.step-down transformers
In an AC.synchronous motor electric propulsion plant,propeller speed is controlled by() A.prime mover speedB.number of energized main motor polesC.propulsion generator field strengthD.electric coupling field strength
The output voltage of a 440 volt, 60 hertz, AC generator is controlled by theA.prime mover speedB.exciter output voltageC.load on the alternatorD.number of poles
The power factor of an AC generator operating singularly is determined by the_______ .A.connected loadB.prime mover speedC.field excitationD.generator's rated voltage
材料:The field current supply in older machines comes from a lower voltage direct current generator or exciter on the same shaft as the alternator. Modern machines however are either statically excited or of the high-speed brush-less type. The exciter is required to operate to counter the effects of power factor for a given load. The power factor is a measure of the phase difference between voltage and current and is expressed as the cosine of the phase angle. With a purely resistance load the voltage and the current are in phase, giving a power factor of one. The power consumed is therefore the product of voltage and current. Inductive or capacitive loads, combined with resistance loads, produce lagging or leading power factors which have a value less than one.The power consumed is therefore the product of current, voltage and power factor. The alternating current generator supplying a load has a voltage drop resulting from the load. When the load has a lagging power factor this voltage drop is considerable. Therefore the exciter, in maintaining the alternator voltage, must vary with load current and also the power factor. The speed change of the prime mover must also be taken into account.问题: The word “machines” in the passage refers to _____.A.the direct current generatorB.the alternating current generatorC.the exciterD.the prime moverWhich of the following statements is true according to the passage ?A.With a purely resistance load, the power factor is zeroB.Inductive loads combined with resistance loads produces leading power factorsC.Capacitive loads combined with resistance loads produces lagging power factorsD.With a purely resistance load, the phase angle is zeroWhen the load has a lagging power factor this voltage drop is considerable. This sentence means that _____.A.with a purely resistance load, the voltage drops too muchB.there is a considerable voltage drop in the capacitive load combined with resistance loadC.when the load is the capacitive load combined with resistance load, the voltage drops to zeroD.when the load is the inductive load combined with resistance load, the voltage drop is fairly largeThe exciter must vary with: ① load current ② the power factor, ③ speed change of the prime mover.A.①B.②C.①②D.①②③请帮忙给出每个问题的正确答案和分析,谢谢!
单选题() is provided to alternators, in the event of prime mover failure to ensure that the alternator does not act as a motor.AReverse current protectionBReverse power protectionCSynchronising deviceDFrequency meter
单选题The main purpose of an electric space heater installed in a large AC generator is to ()Aprevent the windings from becoming brittleBprevent moisture from condensing in the windings during shutdownCprevent acidic pitting of the slip ringsDkeep the lube oil warm for quick starting
单选题A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an ()ArotorBstatorCexciterDarmature
单选题The voltage output of an AC generator is controlled by()Avarying the DC exciter voltageBvarying the reluctance of the air gapCregulating the speed of the prime moverDshorting out part of the armature windings
单选题The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ().AdroopBdropCdipDregulation
单选题The power factor of an AC generator operating singularly is determined by the ()Aconnected loadBprime mover speedCfield excitationDgenerators rated voltage
单选题Diesel engine cylinder head test cocks are used to()Acheck cylinder lubrication prior to starting engineBconnect exhaust gas analyzers to determine engine efficiencyCpressure test cylinder heads to check for leaksDremove moisture accumulations from cylinder prior to starting
单选题When securing an AC generator, you should FIRST ().Aopen the generator circuit breakerBswitch the voltage regulator to “manual”Cdecrease the field excitation to minimumDreduce the load on the unit
单选题To increase the frequency of an operating AC generator, you should ()Aincrease the field excitationBdecrease the field excitationCincrease the number of magnetic polesDincrease the speed of the prime mover
单选题Mooring winches are often combined with () units so that one prime mover drives both.AcraneBhatch coverCwindlassDsteering gear
单选题The star-delta starter is an effective method of () voltage starting of a motor.AincreasedBreducedCunchangedDNone of the above
单选题The frequency of an AC generator is adjusted by means of the ()Amain alternator field rheostatBexciter field rheostatCprime mover governor controlDequalizing reactor
单选题Reduced voltage applied to a motor during the starting period will ().Aresult in decreased acceleration time onlyBlower the starting current and increase accelerating timeCcause a greater starting torqueDincrease the starting current and pump capacity
单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().Ais smallBmay be neglectedCis usefulDis considerable
单选题The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the ().Aprime mover speedBexciter output voltageCload on the alternatorDnumber of poles
单选题The initial voltage of self-excitation generator set up by()Aresidual magnetismBvoltage regulatorCelectrical current for excitationDthe other running generator
单选题Propulsion of the vast majority of contemporary merchant ships (especially containerships and VLCCs) utilizes() as prime mover.Agas turbineBdiesel engineCsteam engineDgasoline engine
单选题The overspeeding of the diesel engine driving an electric generator could cause ().Alow voltage trip to tripBreverse power trip to tripCdamage to windingsDexcessive exhaust temperatures
单选题Overspeed of the diesel engine driving an electric generator could cause().Alow voltage tripBreverse power tripCdamage to windingsDexcessive exhaust temperatures
单选题On a vessel making a voyage more than 48 hours long,regulations require that().Aa lifeboat drill be held within 12 hours prior to departureBfire pumps be tested by starting within 12 hours prior to departureCthe emergency generator and lighting system be tested by starting and operating within 12 hours prior to departureDthe entire steering gear be tested within 12 hours prior to departure
单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()Aslightly less than the oncoming generator frequencyBthe same as the bus frequencyCslightly greater than the bus frequencyDthe same as the bus voltage
单选题The voltage developed by an AC generator is controlled by varying the ()Aspeed of the prime moverBAC excitation to the fieldCDC excitation to the fieldDDC excitation of the voltage regulator