单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().Ais smallBmay be neglectedCis usefulDis considerable

单选题
The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().
A

is small

B

may be neglected

C

is useful

D

is considerable


参考解析

解析: 暂无解析

相关考题:

Cathodic protection involves supplying electrons to the metal to be protected from an external source. The external source maybe be an external _______ or by__________. A、dc power sourceB、Alternating Power SourceC、A Galvanic CoupleD、Cathode

In a modern three-phase A.C. synchronous brushes generator, the excitation winding is on the rotor. That means .A.The generator need not excitation.B.The winding on the rotor is for inputting excitation current.C.There are three phase windings on the rotor.D.The generator has no brushes.

Which of the following components are used to convert alternating current produced in the generator windings to direct current?A.Armature and equalizerB.Commutator and brushesC.Rotor and interpolesD.Field and exciter

材料:The field current supply in older machines comes from a lower voltage direct current generator or exciter on the same shaft as the alternator. Modern machines however are either statically excited or of the high-speed brush-less type. The exciter is required to operate to counter the effects of power factor for a given load. The power factor is a measure of the phase difference between voltage and current and is expressed as the cosine of the phase angle. With a purely resistance load the voltage and the current are in phase, giving a power factor of one. The power consumed is therefore the product of voltage and current. Inductive or capacitive loads, combined with resistance loads, produce lagging or leading power factors which have a value less than one.The power consumed is therefore the product of current, voltage and power factor. The alternating current generator supplying a load has a voltage drop resulting from the load. When the load has a lagging power factor this voltage drop is considerable. Therefore the exciter, in maintaining the alternator voltage, must vary with load current and also the power factor. The speed change of the prime mover must also be taken into account.问题: The word “machines” in the passage refers to _____.A.the direct current generatorB.the alternating current generatorC.the exciterD.the prime moverWhich of the following statements is true according to the passage ?A.With a purely resistance load, the power factor is zeroB.Inductive loads combined with resistance loads produces leading power factorsC.Capacitive loads combined with resistance loads produces lagging power factorsD.With a purely resistance load, the phase angle is zeroWhen the load has a lagging power factor this voltage drop is considerable. This sentence means that _____.A.with a purely resistance load, the voltage drops too muchB.there is a considerable voltage drop in the capacitive load combined with resistance loadC.when the load is the capacitive load combined with resistance load, the voltage drops to zeroD.when the load is the inductive load combined with resistance load, the voltage drop is fairly largeThe exciter must vary with: ① load current ② the power factor, ③ speed change of the prime mover.A.①B.②C.①②D.①②③请帮忙给出每个问题的正确答案和分析,谢谢!

You are upgrading your Cisco router IOS from a TFTP server over the network. The upgrade procedure is stopped and you are prompted to erase the current flash contents before continuing. What is most plausible reason for this? ()A、There is insufficient room for more than one image.B、The router has detected a copy of the current software image on the TFTP server.C、The file can be relocated and not compressed.D、The image to load is a binary executable file.

如何把脚本和结果放到load generator的机器上?

单选题The purpose of DC generator brushes is to ().Aneutralize armature reactionBconduct electric current to an outside circuitCconvert DC current to AC currentDprovide excitation to a DC generator

问答题如何把脚本和结果放到load generator的机器上?

单选题A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an ()ArotorBstatorCexciterDarmature

单选题Generator brushes are staggered to()Areduce current pulsationsBreduce brush chatterCprevent uneven commutator wearDallow greater power generation

单选题The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ().AdroopBdropCdipDregulation

单选题Generators should have an excitation/voltage regulation system which will enable them to share the steady state reactive load () no machine exceeds its proportional share of reactive load by more than 10% of the rated reactive load of the largest generator.AwhenBso asCsuch thatDthough

单选题When securing an AC generator, you should FIRST ().Aopen the generator circuit breakerBswitch the voltage regulator to “manual”Cdecrease the field excitation to minimumDreduce the load on the unit

单选题Self-excited a-cgenerator with "error operated" voltage control systems draw the full excitation power for the machine terminalsThis dispenses with the current transformers, reactors and capacitors necessary for accurate compounding, but renders the excitation system vulnerable to variations in its output voltageWhich of the following is correct about the generator mentioned according to the sentences above ().AIt consumes no excitation powerBIt has current transformersCComponents are needed for accurate compoundingDIts excitation system is vulnerable to voltage variations

单选题In an alternating current electrical system, a low system power factor is a direct sign of ()Awasted energyBefficient operationCa short in the exciter field windingsDan excessive number of minor system grounds

单选题The frequency of the alternating current generated by a synchronous generator is governed by the speed and the()Afull excitationBloadCpower factorDnumber of poles

单选题Possible phase relationships between voltage and current in an alternating current circuit include which of the following conditions?()ACurrent and voltage may be in phaseBCurrent may lead the voltageCCurrent may lag the voltageDAll of the above

单选题Which of the following components are used to convert alternating current produced in the generator windings to direct current?()AArmature and equalizerBCommutator and brushesCRotor and interpolesDField and exciter

单选题The purpose of the commutator and brushes on a DC generator is to()Achange AC to DCcurrentBchange DC to AC currentCneutralize a armature reactionDcarry current to the outside circuit

单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()Aan incorrect diesel generator governor speed droop adjustmentBa faulty reverse power relay within the main circuit breaker assemblyCunsynchronized isochronous load distribution adjustmentsDa different speed setting on each unit

单选题To () , the power is supplied by main switchboard directly not though sub-board.Asave network costBimprove the reliability of supplying power to important loadCprevent sequence reverseDincrease the power factor of important load

单选题The initial voltage of self-excitation generator set up by()Aresidual magnetismBvoltage regulatorCelectrical current for excitationDthe other running generator

单选题Which of the following should be the FIRST step in removing a generator from parallel operation?()ATrip the generator off the switchboardBTurn off all electrical equipmentCRemove the load from the off going generatorDIncrease the cycles of the generator staying on the line

单选题Current changing in direction and rising and falling in value is ().AACBDCCgeneratorDfresh water generator

填空题Nikola Tesla invented alternating current technology that enabled electricity to be transmitted over long distances.____

单选题A vessel is equipped with two ships service generatorsGenerator #1 is rated at 900kw and generator #2 is rated at 600kw.During parallel operation, with a hotel load of 1000kw, what should be the kw load on generator #2 ().A100kwB400kwC500kwD600kw

单选题In a modern three-phase A-Csynchronous brushless generator, the excitation winding is on the rotorThat means ().AThe generator needs not excitationBThe winding on the rotor is for inputting excitation currentCThere are three phase windings on the rotorDThe generator has brushes