单选题If one of the bilge system manifold valves does not properly seat, the ()Abilge well connected to that valve, plus the second bilge well being pumped will be completely emptiedBbilge system will lose vacuum and prevent the other bilges from being pumped outCbilge well aft connected to that valve will siphon its contents to the forward bilge wellsDdischarge pressure will be too high

单选题
If one of the bilge system manifold valves does not properly seat, the ()
A

bilge well connected to that valve, plus the second bilge well being pumped will be completely emptied

B

bilge system will lose vacuum and prevent the other bilges from being pumped out

C

bilge well aft connected to that valve will siphon its contents to the forward bilge wells

D

discharge pressure will be too high


参考解析

解析: 暂无解析

相关考题:

Why does the system fall to arrest a wanted person?A.The system is not effective in recognizing people.B.The system doesn't look at skin color or one's gender.C.The system doesn't consider people's specific features.D.The system is highly inaccurate and can be easily fooled.

Accidental flooding of the engine room bilges by the bilge main is prevented by( ).A.stop-check valves installed in the bilge suction manifoldsB.using a positive displacement reciprocating bilge pumpC.installing educators in all bilge rose boxesD.installing a swing check before each bilge valve

An administrator has just installed a new NIC into the server. The system POSTs fine and the NIC is recognized by the OS, but it does not receive an IP address. Which of the following is the MOST likely cause of this?()A. The NIC is not on the HCL.B. The driver is incorrect on the server.C. The patch cable has not been seated properly.D. The NIC is not seated properly.

A fire pump may be used for other purposes if ______.A.the other services are run off a reducing station with a pressure gageB.one of the required pumps is kept available for use on the fire main system at all timesC.no relief valves are installedD.all of the above conditions are met

The system of valves and cargo lines in the bottom piping network of a tank vessel that connects one section of cargo tanks to another section is called a ______.A.crossoverB.runaroundC.come-alongD.manifold

A vessel in ocean service that does not have an approved means of processing oily bilge slops or oily ballast must have ______.A.a fixed piping system for ballast discharge to a reception facilityB.a discharge outlet for the ballast system on each side of the weather deckC.one portable adapter for a shore connection to the ballast lineD.All of the above

The system of valves and cargo lines in the bottom piping network of a tanker that connects one section of cargo tanks to another section is called a ______.A.come-alongB.crossoverC.manifoldD.runaround

What problem does Hanna Sanchez mention?A.The technican's do not have enough time between sessionsB.One of the rooms is not fully equipped for the presentationsC.One of the presentations will need to be rescheduledD.The lighting in room 106 does not work properly

An administrator has just installed a new NIC into the server. The system POSTs fine and the NIC is recognized by the OS, but it does not receive an IP address. Which of the following is the MOST likely cause of this?()A、The NIC is not on the HCL.B、The driver is incorrect on the server.C、The patch cable has not been seated properly.D、The NIC is not seated properly.

单选题The bilge system has been performing well; however, the aft starboard engine room bilgewell suddenly fails to be pumped outWhich of the following should be done first to determine the cause?()AOpen the bilge pump for inspectionBRemove each of the manifold valvesCRemove only the manifold valve to the affected bilge-wellDAttempt to pump out another bilge well to determine if the entire system is affected

单选题One characteristic of a pulse type turbo-charging system is()Ahigh average exhaust manifoldBgreatly fluctuating inlet manifold pressureCconstant exhaust manifold pressureDmultiple exhaust pipes to the turbocharger

单选题An emergency bilge pumping system is provided and should be () of the main bilge pumping system, according to the SOLAS 74 Convention.AdependentBin dependentCin seriesDin parallel

单选题Where an excessive level of contamination is detected an alarm is sounded and diverting valves are operatedThe discharging liquid is then passed to ().AoverboardBa bilge wellCa slop tankDa hot well

单选题Accidental flooding of the engine room bilges by the bilge main is prevented by ().Astop-check valves installed in the bilge manifoldsBusing a positive displacement reciprocating bilge pumpCinstalling eductors in all bilge rose boxesDinstalling a swing check before each bilge valve

单选题The series of valves used to control the return flow in well control operations is called the().Avalve assemblyBstandpipe manifoldCaccumulator manifoldDchoke manifold

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题The system of valves and cargo lines in the bottom piping network of a tank vessel that connects one section of cargo tanks to another section is called a().AcrossoverBrunaroundCcome-alongDmanifold

单选题In setting the valves on a steam-smothering system on a tank vessel,the master control valve to cargo tanks should be().Aopen and individual tank valves openBopen and the individual tank valves closedCclosed and the individual tank valves closedDclosed and the individual tank valves open

单选题As a watch officer when bunkering, which of the following does require his individual attention?()Adraft of the vesselBrate of deliveryCcommunication with terminal personnelDobservation of manifold valves

单选题Hydraulic cranes must be properly warmed-up before being operated because ().Awarm-up allows the hydraulic system to become charged with oilBwarm-up allows the relief valves to be properly testedChydraulic strainers operate only during the warm-up periodDhydraulic fluid must be at the proper viscosity

单选题A compound gauge is typically installed on the ().Asuction side of a bilge pumpBexhaust manifold of an auxiliary dieselCdischarge line from an air compressorDchemical feed tank of an evaporator

单选题According to the SOLAS convention, the bilge water system ()Amust connect the bilge well suction directlyBshould not pump out the water accumulated in the cargosCshould not used for emergency drainage in case of ship collisionDshould connect to the fire fighting system directly

单选题An administrator has just installed a new NIC into the server. The system POSTs fine and the NIC is recognized by the OS, but it does not receive an IP address. Which of the following is the MOST likely cause of this?()AThe NIC is not on the HCL.BThe driver is incorrect on the server.CThe patch cable has not been seated properly.DThe NIC is not seated properly.

单选题A vessel in ocean service that does not have an approved means of processing oily bilge slops or oily ballast must have().Aa fixed piping system for ballast discharge to a reception facilityBa discharge outlet for the ballast system on each side of the weather deckCone portable adapter for a shore connection to the ballast lineDAll of the above

单选题If one of the bilge system manifold valves does not properly seat, the ()Abilge well connected to that valve, plus the second bilge well being pumped will be completely emptiedBbilge system will lose vacuum and prevent the other bilges from being pumped outCbilge well aft connected to that valve will siphon its contents to the forward bilge wellsDdischarge pressure will be too high

单选题You are unable to pump out the aft starboard engine room bilge well that is fouled, with one foot of water over the top of the bilge well, what actionshould be carried out?()ASend the wiper into the well with only a scoop and pailBRemove the bilge manifold valve and attempt to back flush the lineCSimultaneously operate all available bilge pumpsDIt is only necessary to transfer half the contents of a drum of degreaser into the bilge well

单选题In setting the valves on a steam-smothering system on a tanker,the master control valve to cargo tanks should be().Aopen and individual tank valves openBopen and the individual tank valves closedCclosed and the individual tank valves closedDclosed and the individual tank valves open

单选题The timing of diesel engine air starting valves is controlled by()Athe air start valve timing gears and rodsBa cylinder check valveCindividual cams and valve gearDan air manifold poppet valve