单选题The compressor suction line conveys the refrigerant vapor from () to ().Acondenser;evaporatorBevaporator;compressorCcompressor;condenserDNone of the above

单选题
The compressor suction line conveys the refrigerant vapor from () to ().
A

condenser;evaporator

B

evaporator;compressor

C

compressor;condenser

D

None of the above


参考解析

解析: 暂无解析

相关考题:

In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

In a chilled(冷的) water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ______.A.increasing refrigerant pressure in the coilB.increasing chilled water flow through the coolerC.sub-cooling the refrigerant in the condenserD.superheating the refrigerant in the compressor

The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line

单选题The device, which is installed in the compressor suction line to prevent liquid from entering the compressor when hot gas defrosting, is called a()Are-evaporatorBreceiverCdehydratorDsolenoid

单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().Aflooding backBsuperheatingCoverflowingDrecycling

单选题Insufficient refrigerant in a refrigeration plant may result in ().Ahigh discharge pressureBfrosting of the crankcaseChigh temperature of the overboard waterDlow suction pressure of compressor

单选题If a refrigeration system were short of refrigerant, the condition would result in ().Acontinuous running of the compressorBhigh suction pressureChigh discharge pressureDshort cycling of the compressor on the water failure switch

单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().Aliquid strainerBrefrigerant inlet of the condenserCinlet side of the evaporatorDsuction side of the compressor

单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().Amaintain adequate coil back pressureBprohibit flashing in the liquid lineCreduce refrigerant volume in the systemDreduce compressor discharge line loading

单选题A warmer than normal compressor suction line might be caused by ().Ainsufficient lubricationBinsufficient refrigerantCexcess refrigerantDexcessive opening of the expansion valve

单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve

单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().Arefrigerant boiling out of solution from the lube oilBliquid refrigerant flooding the compressor and systemClube oil viscosity being reduced by refrigerant dilutionDcompressor suction pressure suddenly increasing

单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ().Aincreasing refrigerant pressure in the coilBincreasing chilled water flow through the coolerCsub-cooling the refrigerant in the condenserDsuperheating the refrigerant in the compressor

单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().Aoil foaming in the compressorBhigher than normal suction and discharge pressures with a higher box temperatureChigher than normal discharge pressure with a normal box temperatureDthe compressor to run continuously

单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().AliquidBdry saturated gasCwet saturated gasDsuperheated vapor

单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().Ain the chill boxBbefore the receiverCon the suction side of the compressorDon the discharge side of the compressor

单选题“Flooding back” is a condition where the liquid refrigerant ().Avaporizes in the condenserBreaches the compressor through the suction lineCflashes in the liquid lineDcondenses in the receiver

单选题The purpose of the low pressure cut-out switch is to ().Amaintain liquid refrigerant at the suction of the compressorBmaintain a preset suction pressure to the compressorCstart and stop the compressor at preset operating pressuresDoperate at minimum efficiency

单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().Acondition of the expansion valveBmoisture in the systemCcondition of the compressor suction valvesDcondenser temperature

单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().Acarbon deposits on the compressor suction valvesBthe evaporator temperature to increaseCrapid corrosion of the thermal expansion valveDno operating problems