单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().Ain the chill boxBbefore the receiverCon the suction side of the compressorDon the discharge side of the compressor

单选题
The sensing line for the low pressure cutout switch to a refrigeration system is located ().
A

in the chill box

B

before the receiver

C

on the suction side of the compressor

D

on the discharge side of the compressor


参考解析

解析: 暂无解析

相关考题:

The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure

If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first

Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()ApressurestatBhigh pressure cutoutCsolenoid valveDlow pressure cutout switch

单选题The refrigeration system low pressure cutout switch is actuated by ().Aan electric system managerBa sensing bulb at the tail coil of the evaporatorCpressure changes in the suction lineDfailure of the king solenoid valve

单选题The device used for low-pressure control and high-pressure cutout on a compressor is called a()AcutoutBpressure controllerCcontroller switchDcutout switch

单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().Athe compressor suction pressure is not too highBall air is purged from the pump and charging fittingsCthe high pressure cutout switch is held open to prevent accidental startingDthe condenser is completely shutdown first

单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()Abroken valve springsBtight drive beltsChigh line voltageDair in the system

单选题Two well-developed high pressure areas may be separated by a().AHill of low pressureBTrough of low pressureCValley of low pressureDRidge of low pressure

单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly

单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().Asystem was overcharged with refrigerantBsystem was low on refrigerantCsuction valves were leaking slightlyDrelief valve was leaking slightly

单选题If the compressor runs continually, the cause might be the()Ahigh-pressure cutout switch is jammed openBlow-pressure switch is jammed shutCthermal bulb is not operating properlyDscale trap is clogged

单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow

单选题The correct procedure for giving an auxiliary boiler a bottom blow, is to begin()Awhen the boiler has been secured long enough for most solids to settleBwhen the boiler has been cooled to ambient temperatureConly after raising the water level to within 0~5 inch of the high water cutout onlyDafter bypassing the low pressure

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve

单选题If the head pressure is too high,()Athe relief valve should open before the high-pressure cutoutBthe relief valve should open and let excess refrigerant go to receiverCthe high-pressure cutout switch should operate before the relief valve opensDclose in on the suction valve

单选题The direction of the surface wind is().Adirectly from high pressure toward low pressureBdirectly from low pressure toward high pressureCfrom high pressure toward low pressure deflected by the earth's rotationDfrom low pressure toward high pressure deflected by the earth's rotation

单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()Asystem is overcharged with refrigerantBsystem is low on refrigerantCdischarge valves are leaking excessivelyDdischarge valves are leaking slightly

单选题The purpose of the refrigeration system low pressure cutout switch is to ()Aprotect the compressor from liquid flood backBprotect the compressor from low discharge pressureCstart and stop the compressor upon system demandDstart the compressor after a drop in the evaporator pressure

单选题Diesel engine automated control systems may utilize sensing devices of dual function, with sensing ranges providing both alarm and engine shut down capability.Which of the key points would only require an alarm sensor?()ALube oil pressure and temperatureBjacket water pressure and temperatureCEngine over-speedDLube oil sump level

单选题If a compressor runs continuously, the cause might be a()Adefective thermal bulbBclogged scale trapCstuck high-pressure switchDstuck low-pressure switch

单选题The purpose of the low pressure cut-out switch is to ().Amaintain liquid refrigerant at the suction of the compressorBmaintain a preset suction pressure to the compressorCstart and stop the compressor at preset operating pressuresDoperate at minimum efficiency

单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()AThermal expansion valve frozen openBSuction gas heat exchanger bypassedCCondenser clogged or fouledDHigh pressure cutout switch inoperative