Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line

Which of the problems listed could cause erosion of the expansion valve disks and seats?

A.Overcharging the system with refrigerant

B.Faulty compressor suction valve

C.Failure of the high pressure cutout

D.Flash gas formed in the liquid line


相关考题:

Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve

The main propulsion diesel engine jacket water temperature rises above normal, with the raw sea suction and the expansion tank water level being normal. Which of the following problems is most likely the cause?A.Faulty thermostatic bypass valveB.Eroded zinc pencils in the heat exchangerC.Steam formation in the expansion tankD.Excessive leakage from jacket water pump seals

Which of the listed problems could produce a high absolute pressure within a flash type evaporator?A.production of high salinity distillateB.seawater feed temperature below 165℃C.a leak in the first stage demisterD.a cracked distillate pump vent line

单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()AProper refrigerant chargeBFaulty expansion valveCInsufficient refrigerantDSolenoid valve stuck open

单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()Acold fuel oilBlow fuel oil pressureClow atomizing steam pressureDwater in the fuel oil

单选题Which of the following problems represent one possible cause of high lube oil consumption in a four stroke diesel engine?()AWorn intake valve guidesBPitted pre-combustion chambersCLoose valve tappetsDHigh exhaust back pressure

单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()AShortage of refrigerant oilBSlight shortage of refrigerantCExcessive condenser cooling water flowDFaulty expansion valve

单选题Which of the listed problems can be a cause of low compression pressure in a diesel engine?()Aclogged air filterBcompression strokeCburned exhaust valvesDall of the above

单选题Which of the valves listed is NOT considered to be a hydraulic system directional control valve?()ASpring-centered valveBUnloading valveCThree-position valveDTwo-position valve

单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()AClosing of the solenoid valveBClosing of the expansion valveCAn increase in the suction pressureDDecreasing the suction pressure

单选题Which of the listed problems could produce a high absolute pressure within a flash type evaporator?()AProduction of high salinity distillateBSeawater feed temperature below 165℃CA leak in the first stage demisterDA cracked distillate pump vent line

单选题If the jacket water temperature of an operating diesel engine suddenly rises above normal, the cause can be attributed to ().Aan overfilled expansion tankBexcess chromate treatment of the jacket waterCa clogged raw water sea suctionDcavitation erosion of the heat exchanger tubes

单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().AopenBcloseCremain in its positionDflood the evaporator with refrigerant

单选题Which of the problems listed represents the major difficulty encountered with thermal expansion valve operation?()ALube oil passing through the systemBMoisture or foreign matter collecting at the valve seat and orificeCVariable spring tension caused by the changing temperatureDFrost on the liquid line

单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow

单选题Which of the conditions listed could cause the cylinder relief valves on a large, low-speed, propulsion diesel engine to lift?()APlugged injector nozzlesBExcessive fuel injectionCVery late injection timingDIncorrect crankshaft clearance

单选题Which of the following problems could cause air to blow out through the inlet air filter of a running compressor?()AExcessive compression in the cylinderBA broken intake valveCA dirty inlet filter elementDAn improperly adjusted discharge valve

单选题Which of the following would not cause high suction pressure?()Ainsufficient refrigerationBleaky suction valvesCexpansion valve stuck openDsuction valve not adjusted properly

单选题Moisture in a refrigeration system can cause ().Afreezing the expansion valve closedBcorrosion of system pipingCimproper temperature regulationDall of the above

单选题A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().Areturn to a neutral positionBflood the evaporatorCopenDclose

单选题Which of the listed statements is correct concerning refrigeration systems?()ADehydrators must be used continuously in a refrigeration systemBA 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursCA thermostatic expansion valve is used to control refrigerated space temperatureDThe liquid receiver functions to collect and remove non- condensable gases

单选题If an operating bilge pump is developing good vacuum, but is unable to discharge any water, which of the following problems is the most probable cause?()AThe wearing rings are excessively wornBThe suction strainer is cloggedCThe discharge valve is cloggedDThe shaft is worn

单选题Which of the listed design features is found in an exhaust valve and NOT in an intake valve?()AHard alloy steel constructionBBeveled edges on the valve headCLow alloy steel constructionDPoppet type design

单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()AThe condenser and the expansion valveBThe king valve and the solenoid valveCThe compressor and the expansion valveDThe condenser and the solenoid valve

单选题Which of the following problems would be the probable cause for the faulty operation of a reciprocating air compressor suction valve?()ACarbon build up in the piston ring beltBFaulty operation of a cylinder un-loaderCCompressor operation in an area of high relative humidityDLifting of intercooler rebel valve

单选题A pressure drop in the liquid line of a refrigeration system may cause()Athe solenoid valve to seizeBthe compressor to huntCflash gas to form in the liquid lineDthe expansion valve to freeze open

单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()AThermal expansion valve frozen openBSuction gas heat exchanger bypassedCCondenser clogged or fouledDHigh pressure cutout switch inoperative