单选题What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE?()A2B4C8D16

单选题
What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE?()
A

2

B

4

C

8

D

16


参考解析

解析: 暂无解析

相关考题:

A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server.Which limitation must be considered when planning the system configuration?()A.A VIO server requires a dedicated LHEA port.B.There is a limit of 32 LPARs per virtual LAN.C.Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D.Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE?() A.2B.4C.8D.16

An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A、 4B、 16C、 20D、 32

A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A、1B、7C、15D、31

A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports of an HS22 blade server can support if the blade does not have any expansion blades attached?()A、8B、6C、4D、2

When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A、2B、4C、8D、16

A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance. Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()A、Order a 2-port 1Gbps Ethernet LAN adapter.B、Order a 2-port 10Gbps Ethernet LAN adapter.C、Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.D、Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE()? A、2B、4C、8D、16

A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports an HS22 blade server can support if the blade does not have any expansion blades attached?()A、8 B、6 C、4 D、2

A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached; One 4-port 1Gbps IVE adapterPowerVM Standard Edition; They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()A、A second IVE adapterB、A second processor cardC、PowerVM Enterprise EditionD、An additional cable-management arm

A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()A、A VIO server requires a dedicated LHEA port.B、There is a limit of 32 LPARs per virtual LAN.C、Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D、Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A、 4 B、 16 C、 20 D、 32

What is the maximum number of layers of compression that kaspersky-lab-engine (full AV) can decompress for the HTTP protocol?()A、1B、4C、8D、16

What is the maximum number of monitors that can be used for multiple display in Microsoft Windows 2000 professional. ()A、5B、7C、8D、10

What is the maximum number of primary partitions that can be created in a basic disk.  ()A、2B、3C、4D、5

Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()A、 The physical port can be used as part of a Shared Ethernet Adapter (SEA).B、 All physical ports on the Host Ethernet Adapter (HEA) default to promiscuous mode.C、 Multiple logical ports can be assigned to a physical port if that logical port is in promiscuous mode.D、 All physical ports that belong to the same port group will be set to promiscuous mode on the Host Ethernet Adapter (HEA).

单选题A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports an HS22 blade server can support if the blade does not have any expansion blades attached?()A8 B6 C4 D2

单选题A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance.  Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()AOrder a 2-port 1Gbps Ethernet LAN adapter.BOrder a 2-port 10Gbps Ethernet LAN adapter.CUpgrade the IVE adapter to a 4-port 1Gbps IVE adapter.DUpgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

单选题A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A1B7C15D31

单选题A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached One 4-port 1Gbps IVE adapter PowerVM Standard Edition. They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()AA second IVE adapterBA second processor cardCPowerVM Enterprise EditionDAn additional cable-management arm

单选题When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A2B4C8D16

单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A 4B 16C 20D 32

单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A 4 B 16 C 20 D 32

单选题A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports of an HS22 blade server can support if the blade does not have any expansion blades attached?()A8B6C4D2

单选题A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()AA VIO server requires a dedicated LHEA port.BThere is a limit of 32 LPARs per virtual LAN.CTwo VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.DTwo VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

单选题What is the objective of the superstrict option that can be used when creating mirrors?()AAllows the mirror partitions to spread across a maximum number of disks.BAllows the copy of a partition to be on the same physical volume as the mirrored partition.CPrevents partitions allocated to one logical volume mirror from sharing a physical volume with partitions from another logical volume mirror.DForces copies of logical partitions to be housed on different physical volumes, while allowing a single physical volume to be shared by logical volume mirrors.

单选题Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()A The physical port can be used as part of a Shared Ethernet Adapter (SEA).B All physical ports on the Host Ethernet Adapter (HEA) default to promiscuous mode.C Multiple logical ports can be assigned to a physical port if that logical port is in promiscuous mode.D All physical ports that belong to the same port group will be set to promiscuous mode on the Host Ethernet Adapter (HEA).