A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A、1B、7C、15D、31

A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()

  • A、1
  • B、7
  • C、15
  • D、31

相关考题:

A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server.Which limitation must be considered when planning the system configuration?()A.A VIO server requires a dedicated LHEA port.B.There is a limit of 32 LPARs per virtual LAN.C.Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D.Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE?() A.2B.4C.8D.16

When doing capacity planning for the Virtual I/O Server,what is the most important  consideration?()A、The I/O workload needs of the client LPARsB、The processing requirements of the client LPARsC、The memory requirements of the client LPARsD、The virtual Ethernet requirements between client LPARs

You have a server that runs Windows Server 2008 and has the Windows Server Virtualization (WSv) server role installed. You create a new virtual machine.  You need to configure the virtual machine to meet the following requirements: Allow network communications between the virtual machine and the host system. Prevent communications with other network servers. What should you do first?()A、Install the Microsoft Loopback Adapter.B、Create a new Virtual Network Switch.C、Enable Internet Connection Sharing (ICS).D、Set the Connection to None for the network interface card.

Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()A、Create two virtual adapters on the client, each one from a separate Virtual IO ServerB、Enable dead gateway detection on the client so that the network traffic can be reroutedC、Have a spare network card on standby in the client in case the Virtual IO Server goes downD、Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers

An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A、 4B、 16C、 20D、 32

A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()A、Two dual-port PCIe adaptersB、A four-port PCIe Ethernet adapterC、Four separate PCIe Ethernet adaptersD、Two embedded Integrated Virtual Ethernet adapters (IVE)

Which of the following would be the FIRST step to configure a Virtual I/O Server(VIOS)?()A、Boot the HMC with the VIOS media.B、Assign SAN-attached disks to the database partitions.C、Create logical volumes for the VIOS on rootvg disks.D、Identify the location of the internal SCSI disks for the VIOS.

A customer is debating whether to use Shared Ethernet versus Virtual Ethernet.  Which of the following best describes a key difference between Shared and Virtual Ethernet?()A、Shared Ethernet runs on POWER4 systemsB、Virtual Ethernet runs on POWER4 systemsC、Shared Ethernet requires a Virtual I/O server and Advanced Power VirtualizationD、Virtual Ethernet requires a Virtual I/O server and Advanced Power Virtualization

When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A、2B、4C、8D、16

A customer has just purchased an 8-core POWER 570 which has two dual port 1 Gbps  Integrated Virtual Ethernet (IVE) adapters. The customer wants to implement queue pairs (QPs) to take advantage of parallel processing of network traffic to its client logical partitions. Assuming that the system is to utilize the IVEs in both CECs,  which configuration will allow a logical partition to utilize the entire eight cores for network traffic processing?()A、 Set Multiple Core Scaling (MCS) value of the port group to 8 and set multiple core parameter of the client Ethernet adapters to yes.B、 Set Multiple Core Scaling (MCS) value of the port group to 4 and set multiple core parameter of the client Ethernet adapters to yes.C、 Set Multiple Core Scaling (MCS) value of one of the physical port groups to 4 and set multiple core parameter of the client Ethernet adapters to yes.D、 Set Multiple Core Scaling (MCS) value of one of the physical port groups to 8 and set the multiple core parameter of the client Ethernet adapters to yes.

A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance. Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()A、Order a 2-port 1Gbps Ethernet LAN adapter.B、Order a 2-port 10Gbps Ethernet LAN adapter.C、Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.D、Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE()? A、2B、4C、8D、16

Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()A、Configure a Shared Ethernet Adapter on the Virtual I/O Server.B、Use the same virtual LAN ID on each LPAR.C、Set up IP routing through an LPAR on each system.D、Set up an IP firewall through an LPAR on each system.

A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached; One 4-port 1Gbps IVE adapterPowerVM Standard Edition; They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()A、A second IVE adapterB、A second processor cardC、PowerVM Enterprise EditionD、An additional cable-management arm

Companycom tells the technical sales specialist that recent announcements state that virtual lan in the datacenter is the best option. The customer wants to use interpartition communication to save on adapters and increase performance. The systems are going to have shared and dedicated processor partitions. Some of the partitions will be running AIX 5.2 and some will be running AIX 5.3. The second p5 590 will be running a mixture of AIX 5.3 and Linux partitions with 2.6 kernel. What limitations of vlan/interpartition  communication should be discussed with this customer?()A、Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet is supported on AIX 5L and Linux 2.5 and above. B、Virtual Ethernet can be used within groups of shared OR groups of dedicated processor partitions, but not both simultaneously. Virtual Ethernet comes with AIX 5L, and is supported in AIX 5.2 or AIX 5.3 partitions, but not Linux. C、Virtual Ethernet can be used in both shared and dedicated processor partitions. Virtual Ethernet can run in an AIX 5.3 or Linux 2.6 Kernel, but not AIX 5.2 partitions. Virtual Ethernet can only connect partitions within a single system. D、Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet can connect partitions between systems if the HMC is shared between systems.

A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()A、A VIO server requires a dedicated LHEA port.B、There is a limit of 32 LPARs per virtual LAN.C、Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D、Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A、 4 B、 16 C、 20 D、 32

You are an enterprise administrator for Cer-tech .com. All the servers on the network run Windows Server2008. The network consists of a Server that has the Windows Server virtualization role service installed.You create a new virtual machine, installed Windows Server 2008 on it, and configure it to use the physicalnetwork card of the host server. After this installation and configuration the virtual machine, you wereunable to access network resources from the virtual machine. Which of the following options would youchoose to ensure that the virtual host can connect to the physical network?()A、Install the MS Loopback adapter on the virtual machine.B、Enable the Multipath I/O feature on the host server.C、Install Windows Server virtualization Guest Integration Components on the virtual machine.D、Install the MS Loopback adapter on the host server.E、None of the above

You work as an administrator at ABC.com. The ABC.com network consists of a single domain named ABC.com. All servers in the ABC.com domain, including domain controllers, have Windows Server 2012 R2 installed.ABC.com has a Hyper-V server, named ABC-SR13, which hosts multiple virtual machines. You have enabled the use of Single-root I/O virtualization.Which of the following is TRUE with regards to using Single-root I/O virtualization?()A、It maximizes network throughput, while minimizing network latency.B、It maximizes network throughput, as well as network latency.C、It avoids the virtual switch stack and allows the virtual machine direct access to the actual network switch.D、It prevents the virtual machine from accessing the network switch directly.

单选题A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A1B7C15D31

单选题A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached One 4-port 1Gbps IVE adapter PowerVM Standard Edition. They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()AA second IVE adapterBA second processor cardCPowerVM Enterprise EditionDAn additional cable-management arm

单选题When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A2B4C8D16

单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A 4B 16C 20D 32

单选题What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE?()A2B4C8D16

单选题A customer is debating whether to use Shared Ethernet versus Virtual Ethernet.  Which of the following best describes a key difference between Shared and Virtual Ethernet?()AShared Ethernet runs on POWER4 systemsBVirtual Ethernet runs on POWER4 systemsCShared Ethernet requires a Virtual I/O server and Advanced Power VirtualizationDVirtual Ethernet requires a Virtual I/O server and Advanced Power Virtualization

单选题When doing capacity planning for the Virtual I/O Server,what is the most important  consideration?()AThe I/O workload needs of the client LPARsBThe processing requirements of the client LPARsCThe memory requirements of the client LPARsDThe virtual Ethernet requirements between client LPARs