单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve
单选题
If the head pressure of a reciprocating refrigeration compressor is excessive, ().
A
the relief valve should open before the high pressure cutout
B
the relief valve should open and allow the excess refrigerant to flow to the receiver
C
the high pressure cutout switch should operate before the relief valve opens
D
you should close in on the suction valve
参考解析
解析:
暂无解析
相关考题:
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()ApressurestatBhigh pressure cutoutCsolenoid valveDlow pressure cutout switch
单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().Aincrease the flow of the cooling water through the condenserBadjust the high pressure cutout to maintain the desired pressureCopen the hot gas bypass temporarily to reduce capacityDpurge non-condensable gases to reduce the excess pressure
单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().Acompressor;condenserBcondenser;evaporatorCthrottle valve;evaporatorDevaporator;condenser
单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().Arestriction in refrigerant pipingBair and non-condensable gases in the condenserCwater in the refrigerantDflooding back of liquid refrigerant from the evaporator
单选题() provides the head or pressure to supply the domestic water where required.AThe compressed airBThe compressing airCThe transfer pumpDThe head tank
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()Abroken valve springsBtight drive beltsChigh line voltageDair in the system
单选题Which of the following statements represents the advantage of rotary pumps as compared to reciprocating pumps?()AThe high discharge pressure of the rotary pumps permits a larger volume of fluid per unit time than the reciprocating pumpBRotary pumps are capable of pumping more fluid than reciprocating pumps of the same weightCRotary pumps occupy only one-half the space of reciprocating pumpsDRotary pumps eliminate discharge slippage of the pumped liquid, while this does not hold true for a reciprocating pump
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().Apurge the condenser if the waterside is dirtyBcheck for proper water flow through the condenserCincrease the high pressure cutout settingDreduce the cooling water flow
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly
单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.AincreaseBreduceCmaintain constantDNone of the above is true
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively
单选题In the refrigeration system, a shortage of refrigerant is indicated by ().Athe compressor short cycling on high pressure cut out switchBhigh suction pressureChigh head pressureDbubbles in the sight glass
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve
单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().Ahigh pressure liquid lineBlow pressure liquid lineChigh pressure vapor lineDlow pressure vapor line
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()ACondenser and thermal expansion valveBKing and solenoid valvesCCompressor and thermal expansion valveDCondenser and solenoid valve
单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().Achange the expansion valve adjustmentBreadjust the water regulating valve to increase the flow of waterCpurge air from the condenserDclean the waterside of the condenser
单选题Constant superheat is maintained at the evaporator outlet of a refrigeration coil by a()Asolenoid valveBlow pressure cutout switchCking valveDthermal expansion valve
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system
单选题Bad valves operation of the reciprocating air compressors can be detected by observation of ().Athe discharge temperature lowBthe discharge temperature highCthe discharge pressure riseDthe inter-stage pressure low
单选题The amount of fluid delivered by a reciprocating pump can be regulated by ().Athrottling the pressure lineBchanging the speed of the pistonCeither A or BDNone of the above is tree
单选题The volute of centrifugal pump also acts as a diffuser converting ()into pressure head.Amechanical energyBheat energyCpotential energyDkinetic head