单选题Fusible plugs are installed in fire-tube boilers to ().Aprovide a means of draining the boilerBwarn the engineer of low water levelCcool the crown sheet at high firing ratesDopen the burners electrical firing circuits

单选题
Fusible plugs are installed in fire-tube boilers to ().
A

provide a means of draining the boiler

B

warn the engineer of low water level

C

cool the crown sheet at high firing rates

D

open the burners electrical firing circuits


参考解析

解析: 暂无解析

相关考题:

Fusible plugs are installed in fire-tube boilers to _____.A.provide a means of draining the boilerB.warn the engineer of low water levelC.cool the crown sheet at high firing ratesD.open the burners electrical firing circuits

The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?A.Fusible links must be replaced if a damper is activatedB.Fusible links are tested by applying a source of heat to themC.Fusible links must be replaced at every inspection for certificationD.A fusible link will automatically open after a fire is extinguished and reset the damper

In a CRS cluster with Standby Servers, which of the following statements are true? ()A、The Standby Server can be installed across the WAN from the active server. B、MS SQL 2000 must be installed for the datastores. C、MS SQL 2000 or MSDE can be installed for the datastores. D、On the Standby Server, you must install the same components that are installed on its corresponding active server. E、The Standby Server can be installed on one of the CallManager servers.F、The active server can be installed on one of the CallManager servers.

A technician plugs a USB device into the computer. The system tray displays a message that reports the device is installed, but may not work properly. Which of the following is the MOST likely cause of the message?()A、The device needs a firmware updateB、The device needs an updated driver installedC、The plugged in device is too slow for the USB port speedD、The device is incompatible with the installed version of Windows

Which of the following should Karen, a technician, use to test a parallel port?()A、Line testerB、MultimeterC、Null modem cableD、Loopback plugs

单选题The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?()AA fusible link will automatically open after a fire is extinguished and reset the damperBFusible links must be replaced at every inspection for certificationCFusible links are tested by applying a source of heat to themDFusible links must be replaced if a damper is activated

单选题Fusible-link fire dampers are operated by().Aa break-glass and pull-cable systemBelectrical controls on the bridgeCa mechanical arm outside the vent ductDthe heat of a fire melting the link

单选题The diesel engine exhaust gas bypass, as fitted with some waste heat boilers, is installed to ()Aprevent engine back pressure at heavy loadsBincrease total engine efficiency at low loadsCprevent boiler corrosion at low engine loadsDimprove engine fuel consumption at any load

单选题Waterside scale in a fire-tube boiler may cause ().Aincreased heat transferBfireside erosionChigh steam demandDoverheated tubes

单选题Fusible-link fire dampers are operated by().A8the heat of a fire melting the linkBa break-glass and pull-cable systemCelectrical controls on the bridgeDa mechanical arm outside the vent duct

单选题During extremely cold weather, while starting an engine, it turns too slowly and fails to startThis problem is most likely the result of ()Ahigh fuel oil viscosityBlow fuel oil temperatureChigh lube oil viscosityDenergized glow plugs

单选题Boilers and cylinders are().Araw metallic productsBfinished metallic productsCconsumable productsDManufactured goods of large Size

单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Aremove suspended and precipitated solids from the boiler waterBcompletely drain the boiler in an emergency situationCprevent hardened scale deposits in the water drumDremove floating impurities from the oily water surface

单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()Afiring for extended periods in the low fire modeBoverheating, due to waterside depositsCvarying the water level above the crown sheetDcarrying excessive alkalinity in the boiler water

单选题Fusible plugs are installed in fire-tube boilers to ().Aprovide a means of draining the boilerBwarn the engineer of low water levelCcool the crown sheet at high firing ratesDopen the burners electrical firing circuits

单选题Diesel engine waste heat boiler construction is usually of the fire-tube or()Acyclone furnace boiler typeBdry back boiler typeCwater-tube typeDcritical circulation boiler type

单选题Which of the following statements concerning fire-tube boilers is correct?()ACombustion gases flow through the tubesBFlames impinge on the tubesCCombustion occurs in the tubesDWater flows through the tubes

单选题A technician plugs a USB device into the computer. The system tray displays a message that reports the device is installed, but may not work properly. Which of the following is the MOST likely cause of the message?()AThe device needs a firmware updateBThe device needs an updated driver installedCThe plugged in device is too slow for the USB port speedDThe device is incompatible with the installed version of Windows

单选题Fins are installed on the generating tube surfaces in waste heat boilers to ().Aprevent soot fires in the exhaust systemBprevent exhaust gas erosion of the tubesCincrease the velocity of exhaust gas flowDincrease the rate of heat transfer

单选题The air reservoirs must have () fitted to prevent rupture in the event of fire.Ahigh pressure alarmBfire alarmCextinguishersDfusible plugs

单选题Small oil spills on deck can be kept from going overboard by().Adriving wooden plugs into the ventsBclosing the lids on the ventsCplugging the scuppersDplugging the sounding pipes

单选题A high temperature alarm or () which will melt is used to guard against the explosion of compressor air pipelines.Aa flame trapBa relief valveCa fusible plugDa bursting cap

单选题The procedures recommended for auxiliary boilers having high salinity include ().Atreating with oxygen scavengersBsecuring the boiler and giving it a blowing downCincreasing the pHDreducing the phosphate level

单选题Auxiliary boilers can be classified as()Awater-tube natural circulation boilersBfire-tube boilersCwater-tube forced circulation boilersDall of the above

单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()Acompletely drain the boiler in an emergencyBprevent sludge from forming in the drumCremove floating impurities from the boiler water surfaceDremove settled solids from the water drum

单选题Who is in charge of the auxiliary boilers?()AThe chief engineerBThe second engineerCThe third engineerDThe fourth engineer

单选题When a vessel is in dry-dock, the vessel’s engineers should ().Aexamine the condition of the propellerBchip and paint all hull protection zincsCinstall new docking plugs in all cofferdamsDinspect the hull for hogging or sagging

单选题To find the cause of a gasoline engine’s failure to start,you should().ABreak the joint in the fuel line at the engine and let the gas run in the bilgesBDisconnect the wires at the spark plugs and make the spark jump the gapCPrime the engine with ether through spark plug openingsDVentilate the space,then check the battery,spark plugs,carburetor,and fuel line