IBM(000-087) 题目列表
单选题retail company plans to consolidate 180 existing dual processor Xeon servers, all running a web server application on Windows Server 2003. They are planning consolidating to a single x3950 X5 running vSphere.Which of the following should be discussed with this customer? ()AIs the web content static or dynamic information BConsider two servers for redundancy and failover CWhat is the average CPU utilization of the existing web servers DWill the servers need a SCSI or Fibre Channel storage solution

单选题Which bays do the Multi-Switch Interconnect Module populate? ()A3 and 4 B3, 4, 5, and 6 C7 and 9 D7, 8, 9, and 10

单选题What is the correct procedure to update the UEFI on HX5 with MAX5 blades without using the AMM?()AInsert the ServerGuide CD/DVD, boot the HX5 blade and follow the prompts BBoot the blade from the HX5 Bootable Media Creator (BoMC) and follow the prompts CPress F1 when the HX5 system is booting, select Update UEFI, insert the CD/DVD and select OKDMount the IMM virtual disk

单选题A Customer has a proprietary server deployment solution that uses a combination of disk imaging and application pushing technology.  They need to get a working Windows 2003 image for their new servers as soon as possible for deployment with their provisioning system. Which of the following methods can achieve this? ()AInstall Windows 2003 using the F6 supply Mass Storage Controller option BReplace Customers deployment solution with Tivoli Provisioning Manager for OS Deployment Director Edition CUse ServerGuide to install Windows 2003 DDeploy Customers existing image and use UXSPi to update IBM specific drivers

单选题A medical customer has an installed HS21 blade with no local disk. They are attempting to set up boot from SAN using a Windows 2003 CD. Which sequence is correct for this procedure? ()AInstall Windows from the CD using the QLogic driver provided on the CD, configure the LUN and zone for the target server, and then configure the blade UEFI to boot from SAN.BConfigure the LUN and zone for the target server, install Windows from the CD and press F6 when prompted to supply the driver, and then configure the QLogic adapter BIOS to boot from SAN. CConfigure the LUN and zone for the target server, configure the QLogic adapter BIOS to boot from SAN, install Windows from the CD, and then press F6 when prompted to supply the driver. DConfigure the blade UEFI to boot from SAN, configure the LUN and zone for the target server, and then install Windows from the CD using the QLogic driver provided on the CD

单选题A customer has two Ethernet Switch Modules installed in an IBM BladeCenter Enterprise chassis. The modules were configured identically. The Ethernet module in bay one was inadvertenly reset to factory defaults. Which solution returns the module to the customer-specific configuration?()ABack up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface BSwap the modules, which will automatically resynch the settings stored in the Advanced Management Module CBack up the configuration of the Ethernet module in bay one and restore it to the Ethernet module in bay two using the AMM DRestore the configuration from NVRAM using the Switch Module Web interface

单选题A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. Theustomer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy? ()A12 B10 C8 D6

单选题A System x administrator is considering new storage subsystems. Which of the following is a benefit of SAS over Solid State? ()AHigher transfer speeds BIncreased power consumption with Solid State CIncreased bandwidth DCost per MB

单选题A medical customer has a rack with four BladeCenter H chassis that have been operating normally for several months. After installing a new rack of servers in the data center, the system administrator notices the blowers in the BladeCenters have increased their speed. Which of the following caused this problem? ()AThe room temperature has reached 23C (73.4F). BA Blade within the chassis has been shut down. CThe ambient temperature in the data center has increased DOne of the additional System X servers in the BladeCenter rack has failed.

单选题A customer is looking at an Oracle eBusiness solution. They would like to know what hardware they will need for the solution. They have some preliminary information from Oracle, including hardware requirements and specifics for their environment. Which of the following should be done next?()AConfigure a 2 node x3950 X5 BCustomer needs a System p server to support Oracle applications CDownload the Oracle eBusiness sizing questionnaire from IBM, fill out with customer and submit to IBM for System x sizing DConfigure a system that meets the minimum requirements

单选题A retail customer has a database application that is accessed by a large number of people through a web interface from multiple remote locations. Which of the following questions will provide the information necessary to design the best performing storage solution?()AHow many web servers will be connected to the database?BHow many concurrent applications will run against the database? CHow many concurrent users will be accessing the database? DWhat are the types of transactions run against the database?

单选题A customer is concerned about rising power costs, and the limited space they have left in the computer room. They have been doing some research into virtualization and would like to know if they should pursue this solution.Which of the following architectural features should be discussed with them?()Ax3650 M3 servers and racks Bx3550 M3 servers, VMware and racks CBladeCenter, blades and VMware Dx3620 M3 servers and VMware

单选题A customer asks which bays they could install Multi-Switch Interconnect Module (MSIM). Which of the following is the source of this information?()ACDAT BIBM Systems Director CTivoli Provisioning Manager (TPM) DBladeCenter Interoperability guide

单选题A customer has a BladeCenter H chassis with a single AMM.  The AMM is defective. Which of the following is the method to backup the existing AMM so the new AMM automaticlally picks up the configuration? ()ABack up the AMM configuration to a file BBack up the AMM configuration to the chassis CBack up the AMM using IBM Systems Director DBack up the AMM using Tivoli Storage Manager

单选题A System x client is interested in IBM ToolsCenter Bootable Media Creator but is concerned about functions.Which of the following describes the functions of ToolsCenter Bootable Media ?()AUpdate Firmware, Update Drivers, Run Diagnostics, Install Windows BUpdate Firmware, Run Diagnostics, Install Windows, and Linux Operating SystemsCUpdate Firmware, Run Diagnostics, Install Windows DUpdate Firmware, Update Drivers, Install Windows