单选题On offshore drilling units,emergency lighting and each emergency power system must be tested at least once a().AdayBweekCmonthDyear
单选题
On offshore drilling units,emergency lighting and each emergency power system must be tested at least once a().
A
day
B
week
C
month
D
year
参考解析
解析:
暂无解析
相关考题:
A mobile offshore drilling unit under tow is approaching a fog bank. When should fog signals be started?A.When the towing vessel enters the fogB.When the drilling rig enters the fogC.When the towing vessel can no longer be seen from the rigD.Immediately
A mobile offshore drilling unit will show the day-shape in DIAGRAM 10 to indicate that it is ______.A.at anchorB.being towedC.agroundD.drilling
Temporary Certificates of Inspection for offshore drilling units are effective until the ______.A.Operations Manual is approvedB.Minerals Management Service approval is issuedC.classification society approval is issuedD.permanent Certificate of Inspection is issued
An offshore drilling unit is required to carry on board an operations manual approved by the ______.A.Coast GuardB.National Cargo BureauC.Minerals Management ServiceD.builder
According to the regulations for mobile offshore drilling units,"industrial personnel" are considered to be all persons carried on the ship for the sole purpose of carrying out the industrial business of the unit,except for ______.A.the operator's representativeB.the crew required by the Certificate of InspectionC.the galley personnelD.the designated person in charge
A heavy steel device that is set on the sea floor and used as a drilling template in offshore drilling operations is called a ______.A.temporary guide baseB.permanent guide baseC.guide frameD.foundation template
To determine what navigation lights and day-shapes must be displayed on mobile offshore drilling units under tow,you should check the ______.A.American Bureau of Shipping classification rulesB.International Regulations for Preventing Collisions at SeaC.Safety of Life at Sea ConventionD.Minerals Management Service rules
The emergency source of power for Mobile Offshore Drilling Units should be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the services specified in 5.3.6 of the 1989 MODU Code. Which one of the following service is not required to be supplied from the emergency power for a period of 18 hours?()A、Emergency lighting at every embarkation station on deck and over sidesB、Emergency lighting at the storage positions for firemen’s outfitsC、Fire and gas detection and their alarm systemD、Power to operate the watertight doors and their indicators
单选题A mobile offshore drilling unit under tow is approaching a fog bank. When should fog signals be started? ()AWhen the towing vessel enters the fogBWhen the drilling rig enters the fogCWhen the towing vessel can no longer be seen from the rigDImmediately
单选题Each emergency generator on a mobile offshore drilling unit,when tested,must be run under a full load for at least().Aone hourBtwo hoursCten hoursDfour hours
单选题On offshore drilling units,each EPIRB or SART must be tested once every().AdayBweekCmonthDyear
单选题Temporary Certificates of Inspection for offshore drilling units are effective until the ().AOperations Manual is approvedBMinerals Management Service approval is issuedCclassification society approval is issuedDpermanent Certificate of Inspection is issued
单选题An offshore drilling unit is required to carry on board an operations manual approved by the ().ACoast GuardBNational Cargo BureauCMinerals Management ServiceDbuilder
单选题A mobile offshore drilling unit will show the day-shape in DIAGRAM 10 to indicate that it is ().Aat anchorBbeing towedCagroundDdrilling
单选题A heavy steel device that is set on the sea floor and used as a drilling template in offshore drilling operations is called a().Atemporary guide baseBpermanent guide baseCguide frameDfoundation template
单选题Under the regulations implementing MARPOL, a mobile offshore drilling unit is required to have an International Oil Pollution Prevention (IOPP) certificate when the unit ().Ais drilling on the Outer Continental ShelfBmoves to a new drilling location in U-SwatersCengages in a voyage to a port of another country which is a party of MARPOLDAll of the above
单选题Where must the master or person in charge of a ship record the date of each test of emergency lighting and power systems and the condition and performance of the equipment().AOn the Certificate of InspectionBOn the station billCIn the Operations ManualDIn either the official or unofficial log
单选题To determine the number of Able Seamen required on a mobile offshore drilling unit,you should check the().Aload line certificateBOperations ManualCSafety of Life at Sea CertificateDCertificate of Inspection
单选题In the voyage, when carrying out abandon ship drill () should be test every time.Athe emergency lighting system for muster and abandon shipBair oil emergency shut-downCME emergency operationDmain auxiliary steering gear changing
单选题Which()need NOT be entered in the Official Logbook?AThe testing of the internal combustion engine driven emergency generators at least once each month the vessel is navigatedBThe testing of storage batteries for emergency lighting and power systems once each 6 months the vessel is navigatedCThe actual draft when the vessel arrives in salt water after departing a portDThe testing of the line-throwing appliance once every 3 months
单选题()of the following need not be entered in the official logbook?AThe testing of the internal combustion engine driven emergency generator at least once each month the vessel is navigatedBThe testing of storage betteries for emergency lighting and systems once each 6 months the vessels is navigatedCThe actual draft when the vessel arrives in salt water after department a portDThe testing of the line-throwing appliance once every 3 months
单选题An offshore drilling unit must be equipped with a first aid kit approved by the().ACoast GuardBAmerican Bureau of ShippingCMinerals Management ServiceDMine Safety and Health Administration
单选题The emergency source of power for Mobile Offshore Drilling Units should be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the services specified in 5.3.6 of the 1989 MODU Code. Which one of the following service is not required to be supplied from the emergency power for a period of 18 hours?()AEmergency lighting at every embarkation station on deck and over sidesBEmergency lighting at the storage positions for firemen’s outfitsCFire and gas detection and their alarm systemDPower to operate the watertight doors and their indicators
单选题To determine what navigation lights and day-shapes must be displayed on mobile offshore drilling units under tow,you should check the().AAmerican Bureau of Shipping classification rulesBInternational Regulations for Preventing Collisions at SeaCSafety of Life at Sea ConventionDMinerals Management Service rules
单选题Cargo vessels being navigated,and fitted with emergency lighting and power systems,shall have their emergency systems tested at least once().Aa monthBin each weekCin every 6 monthsDin every 12 months
单选题The International Regulations for Preventing Collisions at Sea contain the requirements for ().Alights that must be displayed on anchor buoysBthe display of load line markingsCminimum horsepower for tugs involved in rig movesDlighting of mobile offshore drilling units being towed
单选题Where must the 0mster or person in charge of a ship record the date of each test of emergency lighting and power systems and the condition and performance of the equipment?()AOn the Certificate of InspectionBOn the Muster List (Station Bill)CIn the Operations ManualDIn either the official or unofficial log