单选题A fire main system must have enough fire hydrants so that each accessible space may be sprayed with().Aa low velocity spray applicatorBa water spray or solid streamCat least two spray patterns of waterDat least 25 psi delivered pressure

单选题
A fire main system must have enough fire hydrants so that each accessible space may be sprayed with().
A

a low velocity spray applicator

B

a water spray or solid stream

C

at least two spray patterns of water

D

at least 25 psi delivered pressure


参考解析

解析: 暂无解析

相关考题:

When will the fire department come to conduct a fire prevention inspection in our company?A. Next month. I’ve checked hydrants and fire-extinguishers on each floorB.Next day. The manager will check hydrants and other equipment in the building.C.Next week. But hydrants and fire extinguishers on each floor has already been checkedD.The day before yesterday. I had already checked hydrants and fire extinguishers on each floor.

Which of the following components provides a direct source of seawater for the fire main system?A.Rose boxB.Sea chestC.Sluice(闸式) valveD.Fire pump stuffing box

Oceangoing dry bulk cargo vessels over 1000 GT must have approved combination-type fire nozzles at all ______.A.Fire stations aboard the vessel,except for those in open deck areas weatherdeck and cargo hold fire stationsB.Interior fire stationsC.Engine room fire stationsD.All of the above

A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main

If not attached to the nozzle, each low-velocity spray applicator on a vessel must be stowed__________.A.in a protected area on the main deckB.inside a machinery space near the entranceC.next to the fire hydrant to which the fire hose is attachedD.on a rack inside the quarters near the entrance

The PSC officers will inspect the emergency power supply ,emergency steering gear, fire lines hydrants, fire hoses, fire hydrants, etc .()A、PSC官员将检查应急电源、应急操舵装置、消防龙头、水龙带、消防栓等。B、港口国监督官员将检查应急电源、应急操舵装置、消防龙头、水龙带、消防栓等。C、A+BD、AB都不对。

单选题If you are fighting a fire below the main deck of your vessel,which action is most important concerning the stability of the vessel?().AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold

单选题The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?()AA fusible link will automatically open after a fire is extinguished and reset the damperBFusible links must be replaced at every inspection for certificationCFusible links are tested by applying a source of heat to themDFusible links must be replaced if a damper is activated

单选题What is the most vulnerable part of the fire main system on board an offshore rig?()AThe fire pumpBExposed hard pipingCThe hydrant valveDThe fire hose

单选题Oceangoing dry bulk cargo vessels over 1000 GT must have approved combination-type fire nozzles at all().Afire stations aboard the vessel,except for those in open deck areas weatherdeck and cargo hold fire stationsBinterior fire stationsCengine room fire stationsDall of the above

单选题If you are fighting a fire below the main deck of your vessel,which action is most importantconcerning the stability of the vessel? ()AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold

单选题The PSC officers will inspect the emergency power supply ,emergency steering gear, fire lines hydrants, fire hoses, fire hydrants, etc .()APSC官员将检查应急电源、应急操舵装置、消防龙头、水龙带、消防栓等。B港口国监督官员将检查应急电源、应急操舵装置、消防龙头、水龙带、消防栓等。CA+BDAB都不对。

单选题For a fire to begin there must be present a combustible material, oxygen or air to ()combustion, and a source of heat at a temperature high enough to start combustion.AbeginBsupportClastDextinguish

单选题Your vessel is equipped with a fixed C02 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?().AUse the C02 system and evacuate the engine roomBUse the fire main system and evacuate the engine roomCEvacuate the engine room and use the C02 systemDEvacuate the engine room and use the fire main system

单选题A fire pump may be used for other purposes if().Athe other services are run off a reducing station with a pressure gageBone of the required pumps is kept available for use on the fire main system at all timesCno relief valves are installedDall of the above conditions are met

单选题Which space(s) on your cargo vessel must have a fire detection system?()AAny compartment containing explosivesBAny compartment adjacent to one containing explosivesCEnclosed spaces which are specially suitable for vehiclesDAll of the above

单选题Which fire detection system is actuated by sensing a heat rise in a compartment?()AManual fire detection systemBAutomatic fire detection systemCSmoke detection systemDWatchman's supervisory system

单选题A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the().Afire hose might be damaged by cargo operationsBvessel is in portCfire-main system is not chargedDfire pumps are used for purposes other than supplying water to the fire main

单选题Each part of the fire-main system located on an exposed deck must be().Aprotected against freezingBlocked to prevent theftCnumbered sequentiallyDpressurized at all times

单选题Each fire hose coupling on a ship must have threads that meet the specifications of the().AAmerican Petroleum InstituteBNational Standard Fire hose CouplingCAmerican Society of Mechanical EngineersDUnderwriter's Laboratories,Inc

单选题Take ()of hydrants, fire hoses and nozzles.AcarefulBcareCcarelessDcarefully

单选题Each fire pump on a ship must have a pressure gauge located at().Athe pump dischargeBthe manifold connectionCeach fire station dischargeDthe pump station

单选题The primary function(s) of an automatic sprinkler system is(are) to().Aextinguish the fire which triggers itBlimit the spread of fire and control the amount of heat producedCprotect people in the areas which have sprinkler headsDalert the crew to the fire

单选题If not attached to the nozzle,each low-velocity spray applicator on a vessel must be stowed().Ain a protected area on the main deckBinside a machinery space near the entranceCnext to the fire hydrant to which the fire hose is attachedDon a rack inside the quarters near the entrance

单选题Why did Russia have so many fires in one month in 2010?ABecause lightening spread the fire.BBecause there was much fuel for fires.CBecause there were not enough firefighters.DBecause it was unusually hot, dry and windy.

单选题In the fire main system, quick cleaning strainers are located at the().Apump suctionsBpump dischargeCfire hydrantsDhose nozzle

单选题()is main emergency fire system in all merchant ships.ACO2 systemBFoam systemCDry power systemDWater supply system