单选题()is main emergency fire system in all merchant ships.ACO2 systemBFoam systemCDry power systemDWater supply system

单选题
()is main emergency fire system in all merchant ships.
A

CO2 system

B

Foam system

C

Dry power system

D

Water supply system


参考解析

解析: 暂无解析

相关考题:

Which of the following components provides a direct source of seawater for the fire main system?A.Rose boxB.Sea chestC.Sluice(闸式) valveD.Fire pump stuffing box

A fire pump may be used for other purposes if ______.A.the other services are run off a reducing station with a pressure gageB.one of the required pumps is kept available for use on the fire main system at all timesC.no relief valves are installedD.all of the above conditions are met

Fire protection regulations for towing vessels require that drills be conducted on board the vessel as if there were an actual emergency.Drills include all of the following,EXCEPT ______.A.testing all alarm and detection systemsB.breaking out and using the vessel's emergency equipmentC.participation by selected crew membersD.one person putting on protective clothing,if the vessel is so equipped

A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main

The high-velocity fog tip used with the all-purpose fire fighting nozzle should always be ______.A.Attached by a chainB.Coated with heavy grease to prevent corrosionC.Painted red for identity as emergency equipmentD.Stored in the clip at each fire station

The international shore connection ______.A.Allows hook up of fire fighting water from shore facilitiesB.Satisfies pollution prevention requirementsC.Allows emergency use of the fire main for deballastingD.Permits discharge of waste oil to shore facilities

The international shore connection required on a ship is designed to ______.A.Permit discharge of waste oilB.Allow hook up of fire fighting water from a dock or another vesselC.Satisfy pollution prevention requirementsD.Allow emergency use of the fire main for deballasting

Fire protection regulations for towing vessels require all crew members to know how to perform each of these tasks EXCEPT ______.A.Start the mechanical ventilation system for the engine roomB.Operate the fuel shut-off for the engine roomC.Operate all fire extinguishing equipment aboard the vessel on board the vessel,including starting the fire pumpD.All of the above

材料:Condor a catamaran vessel operating between the Channel Islands and France.The vessel has two main engines in each hull.All propulsion units are duplicated,with each set independent from the other.Shortly after leaving St Helier,Jersey,with 31 passengers and 18 crew,the fire alarm sounded indicating a fire in the starboard engine room.This was confirmed by the closed circuit television surveillance system which showed flames in the vicinity of the starboard outer main engine.The vessel was immediately stopped,all machinery in the starboard engine room was stopped and the fuel supplies shut down.Jersey Radio was informed of the situation two minutes after the alarm sounded. After closing all ventilation openings and accounting for all personnel,halon fire smothering gas was released into the starboard engine room.This was done five minutes after the fire alarm first sounded. The crew maintained boundary cooling and intermittently operated the sprinkler system to the affected space.Twenty minutes after the alarm sounded the situation was considered to be under control.Using the port main engines the vessel returned to St Helier where assistance was available from shore based emergency services.问题:Condor has two ________ main engines.A.combinedB.independentC.coupleD.doubleThe fire accident happened in ________.A.both the engine roomsB.neither engine roomsC.the port engine roomD.the starboard engine roomThe fire was mainly extinguished with ________.A.waterB.chemical agentC.foamD.powderIt can be concluded that ________.A.no officials from any authority know the accident after it happenedB.some officials ashore must have learnt the accident at very beginningC.there must be casualties even they were not mentioned in the reportD.fire is not dangerous on board vessel请帮忙给出每个问题的正确答案和分析,谢谢!

A datacenter manager would like to ensure that all fire suppression in the datacenter is safe for the equipment in the room. Which of the following classifications should be listed on the fire suppression system?()A、AB、BC、CD、D

Lightening causes a power surge and leads to a fire in the datacenter. Following emergency procedures, which of the following is the FIRST thing the server administrator should do?()A、Turn off all electrical powerB、Remove all backup mediaC、Implement fire suppressionD、Evacuate all personnel

单选题What is the most vulnerable part of the fire main system on board an offshore rig?()AThe fire pumpBExposed hard pipingCThe hydrant valveDThe fire hose

单选题Fire protection regulations for towing vessels require all crew members to know how to perform each of these tasks EXCEPT().Astart the mechanical ventilation system for the engine roomBoperate the fuel shut-off for the engine roomCoperate all fire extinguishing equipment aboard the vessel on board the vessel,including starting the fire pumpDAll of the above

单选题An emergency bilge pumping system is provided and should be () of the main bilge pumping system, according to the SOLAS 74 Convention.AdependentBin dependentCin seriesDin parallel

单选题Which of the following components provides a direct source of seawater for the fire main system?()ARose boxBSea chest or spool pieceCSluice valveDFire pump stuffing box

单选题A cutoff valve in the fire-main system of a ship may be closed to protect the portion of the system on an exposed deck from().Adamage from crane operationsBbeing used for wash down purposesCaccidental diversion of flow to wrong locationDfreezing

单选题A fire in the galley always poses the additional threat of().Acontaminating food with extinguishing agentBshutting all sources of air into the compartmentCclosing the sea chestDa grease fire in the ventilation system

单选题Overhauling a fire in the living quarters on a vessel must include().Aopening dead spaces to check for heat or fireBevacuation of the vesselCsounding the all clear signalDoperation of the emergency generator

单选题Fire protection regulations for towing vessels require that drills be conducted on board the vessel as if there were an actual emergency. Drills include all of the following,EXCEPT().Atesting all alarm and detection systemsBbreaking out and using the vessel's emergency equipmentCparticipation by selected crew membersDone person putting on protective clothing,if the vessel is so equipped

单选题Your vessel is equipped with a fixed C02 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?().AUse the C02 system and evacuate the engine roomBUse the fire main system and evacuate the engine roomCEvacuate the engine room and use the C02 systemDEvacuate the engine room and use the fire main system

单选题A fire pump may be used for other purposes if().Athe other services are run off a reducing station with a pressure gageBone of the required pumps is kept available for use on the fire main system at all timesCno relief valves are installedDall of the above conditions are met

单选题Multiple fire pumps may be used for other purposes provided that one pump is().Aon line to the fire mainBkept available for use on the fire main at all timesCcapable of being connected to the fire mainDrated at or above 125 psi

单选题The primary task of the compressed air system is to deliver the starting air necessary for ()Astarting the MEBstarting the emergency electric alternatorCdriving the main turbineDdriving the turbocharger

单选题According to the SOLAS convention, the bilge water system ()Amust connect the bilge well suction directlyBshould not pump out the water accumulated in the cargosCshould not used for emergency drainage in case of ship collisionDshould connect to the fire fighting system directly

单选题A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the().Afire hose might be damaged by cargo operationsBvessel is in portCfire-main system is not chargedDfire pumps are used for purposes other than supplying water to the fire main

单选题Each part of the fire-main system located on an exposed deck must be().Aprotected against freezingBlocked to prevent theftCnumbered sequentiallyDpressurized at all times

单选题In the fire main system, quick cleaning strainers are located at the().Apump suctionsBpump dischargeCfire hydrantsDhose nozzle