单选题If two AC generators are operated in parallel, the load is distributed evenly by()Aa rheostatBa balancing coilCchanging field excitationDadjusting the governor settings
单选题
If two AC generators are operated in parallel, the load is distributed evenly by()
A
a rheostat
B
a balancing coil
C
changing field excitation
D
adjusting the governor settings
参考解析
解析:
暂无解析
相关考题:
( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators
You are attempting to parallel two AC.generators, and the synchroscope pointer revolving in the fast direction.This indicates that the frequency of the incoming machine is A.higher than the bus equencyB.lower than the bus equencyC.the same as the bus frequency but out of phase with itD.same as the bus frequency and the circuit breaker may be closed at
In which two scenarios do you use SQL* Loader to load data?() A. Transform the data while it is being loaded into the database.B. Use transparent parallel processing without having to split the external data first.C. Load data into multiple tables during the same load statement.D. Generate unique sequential key values in specified columns.
When the prime movers of two paralleled generators are equipped with mechanical-hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will .A.pick up more of any increase in loadB.pick up less of any increase in loadC.share an equal amount of any increase in loadD.drop an equal amount of any decrease in load
You are attempting to parallel two AC generators and the synchroscope pointer is revolving in the slow direction. This indicates that the frequency of the incoming machine isA.higher than the bus frequencyB.lower than the bus frequencyC.file same as file bus frequency but out of phase with itD.the same as the bus frequency, and the circuit breaker may be closed at nay pointer position
While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.A.running at the same speedB.groundedC.of the same polarityD.in phase
The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.A.load limit settingsB.idle speed settingsC.speed limit settingsD.speed droop settings
Which data synchronization options between two geographical locations are supported by PowerHA SystemMirror?()A、Parallel and SerialB、Serial and AsynchronousC、Parallel and SynchronousD、Synchronous and Asynchronous
单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().Avoltage regulatorsBfield rheostatsCreverse power relaysDprime mover governors
单选题Which is a function of the voltage regulators used with AC generators?()ATo cut out generators when they are no longer requiredBTo cut in additional generators automatically as requiredCTo divide the KW load equally between generators operating in parallelDTo divide reactive current between generators operating in parallel
单选题The load between two steam-driven alternators operating in parallel may be adjusted by varying ()Athe speed of the alternatorsBthe field strength of the machinesCthe power factor of the alternatorsDsteam supply to the prime movers
单选题Generators should have an excitation/voltage regulation system which will enable them to share the steady state reactive load () no machine exceeds its proportional share of reactive load by more than 10% of the rated reactive load of the largest generator.AwhenBso asCsuch thatDthough
单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().Arunning at the same speedBgroundedCof the same polarityDin phase
多选题In which two scenarios do you use SQL* Loader to load data?()ATransform the data while it is being loaded into the database.BUse transparent parallel processing without having to split the external data first.CLoad data into multiple tables during the same load statement.DGenerate unique sequential key values in specified columns.
单选题When the prime movers of two paralleled generators are equipped with mechanical- hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will ().Apick up more of any increase in loadBpick up less of any increase in loadCshare an equal amount of any increase in loadDdrop an equal amount of any decrease in load
单选题The load sharing characteristics of two diesel generator operating in parallel are mostly dependent on their governor ().Aload limit settingsBidle speed settingsCspeed limit settingsDspeed droop settings
单选题Which of the listed governor characteristics will greatly affect the load sharing relationship between paralleled diesel generators?()ASensitivityBPowerCSpeed droopDCompensation
单选题On commonly used ships,if two A√Cgenerators are operated in parallel, the load is distributed evenly by ().Avarying the D-Cexciter voltageBvarying the reluctance of the air gapCregulating the speed of prime moverDshorting out part of the armature windings
单选题When two DC generators operate in parallel, they are protected against motorizing by()Ablow out coilsBgovernor relayCunder voltage tripsDreverse current trips
单选题If two AC generators are to be operated in parallel, the load is distributed evenly by()Ameans of rheostat the governor settingsBa balance coil excitationCadjusting the governor settingsDchanging excitation
单选题You are attempting to parallel two AC generators, and the syncope pointer is revolving in the fast directionThis indicates that the frequency of the incoming machine is ().Ahigher than the bus frequencyBlower than the bus frequencyCthe same as the bus frequency but out of phase with itDthe same as the bus frequency and the circuit breaker may be closed at any pointer position
单选题You have two EBGP peers connected via two parallel serial lines. What should you do to be able to load-balance between two EBGP speakers over the parallel serial lines in both directions? ()Anothing,BGP automatically load-balances the traffic between different autonomous systems on all available linksBpeer between the eBGP speaker’s loopbacks, configuring eBGP multihop as required, and use an IGP to load-share between the two equal-cost paths between the loopback addressesCconfigure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the EBGP peer loopback address;it is also necessary to use the next-hop-self commandDuse the ebgp-load-balance command on the neighbor statement on both sidesEconfigure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the peer loopback address;it is also necessary to use the ebgp-multihop and next-hop-self commands
单选题A vessel is equipped with two ships service generatorsGenerator #1 is rated at 900kw and generator #2 is rated at 600kw.During parallel operation, with a hotel load of 1000kw, what should be the kw load on generator #2 ().A100kwB400kwC500kwD600kw
单选题If two A.C.generators are to be operated in parallel, the load is distributed evenly by()Ameans of rheostat the governor settingsBa balance coil excitationCadjusting the governor settingsDchanging excitation
单选题Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine ()Aslightly less than the line frequencyBthe same as the line frequencyCslightly greater than the line frequencyDAll of the above
单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()Aslightly less than the oncoming generator frequencyBthe same as the bus frequencyCslightly greater than the bus frequencyDthe same as the bus voltage