单选题The load between two steam-driven alternators operating in parallel may be adjusted by varying ()Athe speed of the alternatorsBthe field strength of the machinesCthe power factor of the alternatorsDsteam supply to the prime movers
单选题
The load between two steam-driven alternators operating in parallel may be adjusted by varying ()
A
the speed of the alternators
B
the field strength of the machines
C
the power factor of the alternators
D
steam supply to the prime movers
参考解析
解析:
暂无解析
相关考题:
The division of kilowatt load between two paralleled alternators is determined by theA.amount of field excitation of the leading machineB.load-speed characteristics of the governorsC.amount of field excitation to the lagging machineD.type of alternator
Diesel engines driving alternators operating in parallel must maintain a set frequency regardless of load changes. The governor characteristic used to accomplish this is known as _______.A.actuationB.sensitivityC.compensationD.promptness
The operation of _______two alternators requires the voltages to be equal and also in phaseA.parallelingB.series-mountingC.runningD.controlling
The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.A.load limit settingsB.idle speed settingsC.speed limit settingsD.speed droop settings
In which two locations in an enterprise network can an IPS sensor be placed?()A、bridging VLANs on two switchesB、bridging two VLANs on one switchC、between two Layer 2 devices withtrunkingD、between two Layer 2 devices withouttrunkingE、between a Layer 2 device and a Layer 3 device withtrunking
What are two characteristics of Server Load Balancing router mode?()A、 The design supports multiple server subnets Cisco 642-874: Practice ExamB、 An end-user sees the IP address of the real serverC、 SLB routes between the outside and inside subnetsD、 The source or destination MAC address is rewritten, but the IP addresses left aloneE、 SLB acts as a "bump in the wire" between servers and upstream firewall or Layer 3 devices
SQ L*Loader is a utility that can perform which two tasks?()A、Load data from a disk, tape, or named pipes.B、Load data into an Oracle database using DML statements.C、Extract, reorganize, and insert data within an Oracle database.D、Load data from external files into tables in an Oracle database.E、Load data into an Oracle database using operating system commands.F、Load data directly from a non-Oracle database to an Oracle database.
In which two locations in an enterprise network can an IPS sensor be placed? ()A、 bridging VLANs on two switchesB、 bridging two VLANs on one switchC、 between two Layer 2 devices with trunkingD、 between two Layer 2 devices without trunkingE、 between a Layer 2 device and a Layer 3 device with trunking
Which three statements about anycast RP are true? ()A、MSDP is running between anycast RPsB、Anycast RP provides redundancy and load-sharing capabilitiesC、Multicast BGP is running between anycast RPsD、In anycast RP,two or more RPs are configured with the same multicast IP address on loopback interfacesE、In anycast RP,two or more RPs are configured with the same unicast IP address on loopback interfaces
When load balancing traffic between two web servers, which of the following technologies provides the LOWEST cost solution?()A、 Active/passive clusterB、 Active/active clusterC、 Log shippingD、 DNS round robin
Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()A、MulticastB、Active/passive clusterC、Active/active clusterD、DNS round robin
An enterprise has two nodes: -Node ’A’ runs a large relational database and ha six CPUs and 32GB of memory. -Node ’B’ is an application server with three CPU’s and 16GB of memory. During peak production periods, the CPU load for Node ’A’ is normally between 30% and 40%. For Node ’B’, the CPU load is 10% to 20% during peak production periods. Which of the following describes the best solution for an HACMP cluster?() A、 Two cluster with two resource groups in a mutual takeover configuration.B、 One cluster with two cascading resource groups in a mutual takeover configuration.C、 One cluster with two rotating resource groups in a one-sided hot standby configuration.D、 Two clusters with two resource groups in a hot-standby configuration with a newly acquired third node.
单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().Avoltage regulatorsBfield rheostatsCreverse power relaysDprime mover governors
单选题Which is a function of the voltage regulators used with AC generators?()ATo cut out generators when they are no longer requiredBTo cut in additional generators automatically as requiredCTo divide the KW load equally between generators operating in parallelDTo divide reactive current between generators operating in parallel
单选题The () engine is used for alternators and some times for main propulsion with a gearbox to provide a propeller of between 90 to 120 rpm.Afour-strokeBtwo-strokeCslow speedDreversible
单选题The () engine is used for alternators and sometimes for main propulsion with a gearbox to provide a propeller of between 90 to 120 rpm.Afour-strokeBtwo-strokeCslow speedDreversible
单选题Diesel engines driving alternators operating in parallel must maintain set frequency regardless of load changesThe governor characteristic used to accomplish this is known as ()AactuationBsensitivityCcompensationDthrust shaft
单选题Thirty-five percent of the breaking strength of an anchor cable is generally accepted as the().Asafe operating loadBnormal operating tensionCemergency working loadDallowable storm load
单选题The load sharing characteristics of two diesel generator operating in parallel are mostly dependent on their governor ().Aload limit settingsBidle speed settingsCspeed limit settingsDspeed droop settings
单选题The operation of paralleling two alternators requires the voltages to be ()and also in phase.AzeroBeliminatedCdifferentDequal
单选题When load balancing traffic between two web servers, which of the following technologies provides the LOWEST cost solution?()A Active/passive clusterB Active/active clusterC Log shippingD DNS round robin
多选题What are two functions that the parameter max-session performs? ()(Choose two.)ADefines the session limit for the domain.BDefines the session limit for the tunnel instance.CUsed to control load balancing between multiple domains.DUsed to control load balancing between multiple tunnels for a domain.
单选题You have two EBGP peers connected via two parallel serial lines. What should you do to be able to load-balance between two EBGP speakers over the parallel serial lines in both directions? ()Anothing,BGP automatically load-balances the traffic between different autonomous systems on all available linksBpeer between the eBGP speaker’s loopbacks, configuring eBGP multihop as required, and use an IGP to load-share between the two equal-cost paths between the loopback addressesCconfigure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the EBGP peer loopback address;it is also necessary to use the next-hop-self commandDuse the ebgp-load-balance command on the neighbor statement on both sidesEconfigure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the peer loopback address;it is also necessary to use the ebgp-multihop and next-hop-self commands
单选题Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()A MulticastB Active/passive clusterC Active/active clusterD DNS round robin
单选题Which is the winter load waterline on the load waterline mark?().AThe line over the summer load waterlineBThe line above the tropical load waterlineCThe line below the tropical load waterlineDThe line between the summer and the winter north Atlantic load waterline
单选题To equalize the power factor of two alternators operating in parallel, the ()Afield excitation of both units is adjustedBgovernors of both units are adjustedCphase sequence is alteredDkilowatt load is evenly divided
单选题The division of kilowatt load between two paralleled alternators is determined by the ()Aamount of field excitation of the leading machineBload-speed characteristics of the governorsCamount of field excitation to the lagging machineDtype of alternator