单选题If two AC generators are to be operated in parallel, the load is distributed evenly by()Ameans of rheostat the governor settingsBa balance coil excitationCadjusting the governor settingsDchanging excitation

单选题
If two AC generators are to be operated in parallel, the load is distributed evenly by()
A

means of rheostat the governor settings

B

a balance coil excitation

C

adjusting the governor settings

D

changing excitation


参考解析

解析: 暂无解析

相关考题:

How many generators does the shuttle carry?A.One.B.Two.C.Three.D.Four.

( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators

You are attempting to parallel two AC.generators, and the synchroscope pointer revolving in the fast direction.This indicates that the frequency of the incoming machine is A.higher than the bus equencyB.lower than the bus equencyC.the same as the bus frequency but out of phase with itD.same as the bus frequency and the circuit breaker may be closed at

You are attempting to parallel two AC generators and the synchroscope pointer is revolving in the slow direction. This indicates that the frequency of the incoming machine isA.higher than the bus frequencyB.lower than the bus frequencyC.file same as file bus frequency but out of phase with itD.the same as the bus frequency, and the circuit breaker may be closed at nay pointer position

Equal power factors on paralleled AC generators are maintained by an automatic ________.A.governor control switchB.reverse power relayC.reverse current relayD.voltage regulator

While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.A.running at the same speedB.groundedC.of the same polarityD.in phase

The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.A.load limit settingsB.idle speed settingsC.speed limit settingsD.speed droop settings

Tensile stress is a result of two forces acting in ______.A.opposite directions on the same line,tending to pull the material apartB.opposite directions on the same line,tending to compress the objectC.opposite directions along parallel linesD.the same direction along parallel lines

Which data synchronization options between two geographical locations are supported by PowerHA SystemMirror?()A、Parallel and SerialB、Serial and AsynchronousC、Parallel and SynchronousD、Synchronous and Asynchronous

单选题Voltage generated by most AC generators is fed from the machine to the bus by means of().Abrushes on a commutatorBbrushes on slip ringsCslip rings on a commutatorDdirect connections from the stator

单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().Avoltage regulatorsBfield rheostatsCreverse power relaysDprime mover governors

单选题Which is a function of the voltage regulators used with AC generators?()ATo cut out generators when they are no longer requiredBTo cut in additional generators automatically as requiredCTo divide the KW load equally between generators operating in parallelDTo divide reactive current between generators operating in parallel

单选题Tensile stress is a result of two forces acting in().Aopposite directions on the same line,tending to pull the material apartBopposite directions on the same line,tending to compress the objectCopposite directions along parallel linesDthe same direction along parallel lines

单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().Arunning at the same speedBgroundedCof the same polarityDin phase

单选题In () technology, two separate and complete processing units run in parallel on a Single chip.AHyper-threadingBCachingCMulti-taskingDDual-core

单选题The distance between any two meridians measured along a parallel of latitude and expressed in miles is the ().Adifference in longitudeBmid-longitudeCdepartureDmeridian angle

单选题Equal power factors on paralleled AC generators are maintained by an automatic ().Avoltage regulatorBreverse power relayCreverse current relayDgovernor control switch

单选题On commonly used ships,if two A√Cgenerators are operated in parallel, the load is distributed evenly by ().Avarying the D-Cexciter voltageBvarying the reluctance of the air gapCregulating the speed of prime moverDshorting out part of the armature windings

单选题The result of two forces acting in opposite directions and along parallel lines,is an example of what type of stress?()ATensileBCompressionCShearDStrain

单选题When two AC generators are being paralleled, the breaker should be closed with the synchroscope pointer mating in the ()Aslow direction, just before the 12 o'clock positionBfast direction, just after the 12 o'clock positionCfast direction, just before the 12 o'clock positionDslow direction, just after the 12 o'clock position

单选题When paralleled, AC generators must have the same ()AfrequencyBnumber of phasesCphase rotationDAll of the above

单选题When two DC generators operate in parallel, they are protected against motorizing by()Ablow out coilsBgovernor relayCunder voltage tripsDreverse current trips

单选题You are attempting to parallel two AC generators, and the syncope pointer is revolving in the fast directionThis indicates that the frequency of the incoming machine is ().Ahigher than the bus frequencyBlower than the bus frequencyCthe same as the bus frequency but out of phase with itDthe same as the bus frequency and the circuit breaker may be closed at any pointer position

单选题If two AC generators are operated in parallel, the load is distributed evenly by()Aa rheostatBa balancing coilCchanging field excitationDadjusting the governor settings

单选题If two A.C.generators are to be operated in parallel, the load is distributed evenly by()Ameans of rheostat the governor settingsBa balance coil excitationCadjusting the governor settingsDchanging excitation

单选题Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine ()Aslightly less than the line frequencyBthe same as the line frequencyCslightly greater than the line frequencyDAll of the above

单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()Aslightly less than the oncoming generator frequencyBthe same as the bus frequencyCslightly greater than the bus frequencyDthe same as the bus voltage