单选题The load sharing characteristics of two diesel generator operating in parallel are mostly dependent on their governor ().Aload limit settingsBidle speed settingsCspeed limit settingsDspeed droop settings

单选题
The load sharing characteristics of two diesel generator operating in parallel are mostly dependent on their governor ().
A

load limit settings

B

idle speed settings

C

speed limit settings

D

speed droop settings


参考解析

解析: 暂无解析

相关考题:

The division of kilowatt load between two paralleled alternators is determined by theA.amount of field excitation of the leading machineB.load-speed characteristics of the governorsC.amount of field excitation to the lagging machineD.type of alternator

Which term describes a group of packets sharing common forwarding characteristics?() A. common forwarding classB. forwarding equivalence classC. equivalent class characteristicsD. forwarding class characteristics

The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.A.load limit settingsB.idle speed settingsC.speed limit settingsD.speed droop settings

Hot Standby Router Protocol (HSRP) is able to provide network redundancy for IP networks. Concerning HSRP load sharing, which two descriptions make sense?()A、It is achieved by using more than one HSRP group.B、It is done in regards to either round robin or weight basis.C、It is used to offload the active router in a certain HSRP group.D、The return traffic is influenced by HSRP load sharing configuration.E、Single group HSRP is used to achieve more efficient link utilization.

Routers R1 and R2 use HSRP so that one router will back up the other should there be a failure.   Which two statements are true about the Hot Standby Router Protocol (HSRP)? ()A、 Load sharing with HSRP is achieved by creating multiple subinterfaces on the HSRP routers.  B、 Routers configured for HSRP can belong to multiple groups and multiple VLANs.C、 Load sharing with HSRP is achieved by creating HSRP groups on the HSRP routers.D、 All routers configured for HSRP load balancing must be configured with the same priority.  E、 Routers configured for HSRP must belong to only one group per HSRP interface.

如何把脚本和结果放到load generator的机器上?

Which three statements about anycast RP are true? ()A、MSDP is running between anycast RPsB、Anycast RP provides redundancy and load-sharing capabilitiesC、Multicast BGP is running between anycast RPsD、In anycast RP,two or more RPs are configured with the same multicast IP address on loopback interfacesE、In anycast RP,two or more RPs are configured with the same unicast IP address on loopback interfaces

Which two of the following statements are true about HSRP load sharing?() (Choose two)A、It is achieved by using more than one HSRP group.B、It is done in regards to either round robin or weight basis.C、It is used to offload the active router in a certain HSRP group.D、Single group HSRP is used to achieve more efficient link utilization.E、The return traffic is influenced by HSRP load sharing configuration.

单选题If a diesel engine driving a generator turns over freely but fails to fire properly, the cause could be ()Aexcessive compression pressureBair in the fuel linesChigh fuel pressureDexcessive load

问答题如何把脚本和结果放到load generator的机器上?

单选题Typical marine propulsion plants include() directly coupled to the vessel’s single large-diameter, fixed-pitch propeller.Aa single, long-stroke, slow-speed, turbocharged, two-stroke diesel engineBa single, long-stroke, medium-speed, turbocharged, four-stroke diesel engineCtwo medium-speed, turbocharged, four-stroke diesel enginesDa variable-speed AC generator

单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().Avoltage regulatorsBfield rheostatsCreverse power relaysDprime mover governors

单选题To check the setting of the overspeed trip on a diesel powered generator, you would use a ().AtachometerBtorsion meterCdynamometerDpony brake

单选题When securing an AC generator, you should FIRST ().Aopen the generator circuit breakerBswitch the voltage regulator to “manual”Cdecrease the field excitation to minimumDreduce the load on the unit

单选题An emergency diesel generator should automatically shut down in the event of ()Adangerous over-speedingBa loss of lube oil pressureCactivation of the fixed CO2 system for the emergency generator spaceDall of the above

单选题Large, two-stroke/cycle, main propulsion, diesel engine cylinders can be successfully pressure charged during normal operation, by using the ().Aexhaust gas temperature systemBexhaust load systemCconstant or pulse pressure systemDconstant volume system

单选题Which of the listed governor characteristics will greatly affect the load sharing relationship between paralleled diesel generators?()ASensitivityBPowerCSpeed droopDCompensation

单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().Ais smallBmay be neglectedCis usefulDis considerable

单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()Aan incorrect diesel generator governor speed droop adjustmentBa faulty reverse power relay within the main circuit breaker assemblyCunsynchronized isochronous load distribution adjustmentsDa different speed setting on each unit

单选题Which term describes a group of packets sharing common forwarding characteristics?()Acommon forwarding classBforwarding equivalence classCequivalent class characteristicsDforwarding class characteristics

单选题Which of the following statements is correct regarding a turbocharged four-stroke/cycle diesel generator?()AAt zero load the intake manifold pressure is greater than the exhaust manifold pressureBAt full load the intake manifold pressure and exhaust manifold pressure are equalCAt full load the intake manifold pressure is less than the exhaust manifold pressureDAt full load the intake manifold pressure is greater than the exhaust manifold pressure

单选题In a single acting, two-stroke/cycle, diesel generator engine, the power impulse in an individual cylinder occurs ()Aonce every crankshaft revolutionBonce every two crankshaft revolutionsConce every piston strokeDtwice every piston stoke

单选题Which of the following should be the FIRST step in removing a generator from parallel operation?()ATrip the generator off the switchboardBTurn off all electrical equipmentCRemove the load from the off going generatorDIncrease the cycles of the generator staying on the line

多选题Hot Standby Router Protocol (HSRP) is able to provide network redundancy for IP networks. Concerning HSRP load sharing, which two descriptions make sense?()AIt is achieved by using more than one HSRP group.BIt is done in regards to either round robin or weight basis.CIt is used to offload the active router in a certain HSRP group.DThe return traffic is influenced by HSRP load sharing configuration.ESingle group HSRP is used to achieve more efficient link utilization.

单选题A vessel is equipped with two ships service generatorsGenerator #1 is rated at 900kw and generator #2 is rated at 600kw.During parallel operation, with a hotel load of 1000kw, what should be the kw load on generator #2 ().A100kwB400kwC500kwD600kw

多选题Which two of the following statements are true about HSRP load sharing?() (Choose two)AIt is achieved by using more than one HSRP group.BIt is done in regards to either round robin or weight basis.CIt is used to offload the active router in a certain HSRP group.DSingle group HSRP is used to achieve more efficient link utilization.EThe return traffic is influenced by HSRP load sharing configuration.

单选题The division of kilowatt load between two paralleled alternators is determined by the ()Aamount of field excitation of the leading machineBload-speed characteristics of the governorsCamount of field excitation to the lagging machineDtype of alternator