单选题After passing through the expansion valve the refrigerant should be in the state of ().AvaporBliquidCsolidDNone of the above is tree

单选题
After passing through the expansion valve the refrigerant should be in the state of ().
A

vapor

B

liquid

C

solid

D

None of the above is tree


参考解析

解析: 暂无解析

相关考题:

To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid

If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()AProper refrigerant chargeBFaulty expansion valveCInsufficient refrigerantDSolenoid valve stuck open

单选题The thermal expansion valve controls the amount of refrigerant that is allowed to flow to the ().AcompressorBcooling coilsCcondenserDreceiver

单选题If a refrigeration system compressor crankcase is sweating, you should ().Aadd refrigerant to the systemBadjust the thermal expansion valve to the proper settingCadjust the float valve to the proper holding pressureDopen the hand expansion valve

单选题When you adjust a thermostatic expansion valve, ().Arefrigerant must be bled off the sensing line before adjustments are madeBall refrigerant must be pumped into the receiver before adjustments are madeCtime must be allowed for conditions to stabilize in the evaporator before further adjustments are madeDall refrigerant must be routed through the dehydrator while changing the superheat setting

单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()AShortage of refrigerant oilBSlight shortage of refrigerantCExcessive condenser cooling water flowDFaulty expansion valve

单选题As the refrigerant passes through the valve orifice, its pressure is reduced and part of the refrigerant turns into ().AliquidBoily mixtureCemulsionDvapor

单选题A three-way thermostatic control valve regulates the diesel engine cooling water temperature by passing a portion of the water ().Aaround the engineBaround the coolerCto the expansion tankDoverboard

单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.AcompressorBcondenserCthrottle valveDevaporator

单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().AopenBcloseCremain in its positionDflood the evaporator with refrigerant

单选题Which of the problems listed represents the major difficulty encountered with thermal expansion valve operation?()ALube oil passing through the systemBMoisture or foreign matter collecting at the valve seat and orificeCVariable spring tension caused by the changing temperatureDFrost on the liquid line

单选题A pressure drop through the refrigerant liquid line may cause ().Asolenoid valve to seizeBcompressor to huntCformation of flash gas in the liquid lineDexpansion valve to freeze open

单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().Apassing it through the expansion valveBcondensing refrigerant in the system condenserCpassing the gaseous refrigerant through the heat interchanger on the suction side of the compressorDmaintaining a high pressure on the systems receiver

单选题After passing through the turbine the exhaust gas is conducted out into the().AintercoolerBcompressorCcylinderDopen air

单选题Because the expansion valve is just () way open, the refrigerant is under low pressure in the evaporator.AlittleBfewCa littleDa few

单选题Moisture in the refrigerant may ().Afreeze on the expansion valve seat and reduce the flow of liquid refrigerantBemulsify the oil in the condenserCfreeze in the king valveDclog the oil trap

单选题The thermal expansion valve reacts directly to the ()Atemperature in the space being cooledBliquid refrigerant pressure at the solenoid valveCpressure drop across the evaporator coilsDrefrigerant gas superheat at the coil outlet

单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()Asuction service valve as a vaporBsuction service valve as a liquidCdischarge service valve as a vaporDcharging valve as a liquid

单选题To add refrigerant to the high side of an air conditioning system, you should introduce the refrigerant through the ().Adischarge service valve as a vaporBsuction service valve as a liquidCcharging valve as a liquidDcondenser purge valve as a vapor

单选题If the thermal bulb of an expansion valve is incorrectly placed at the center of the coil instead of the end, it will ().Aincrease the capacity of the coilBincrease the superheat at the bulbCdeliver more refrigerant to the coilDdecrease the capacity of the coil

单选题The thermostatic valve has a throttling action, that is to say the valve can()Astop the refrigerant from flowingBforce the refrigerant to flowCcause the refrigerant pressure to riseDcause the refrigerant pressure to fall

单选题Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()AAt the designed operating temperature, the liquid refrigerant charge has changed to a vaporBThe liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivityCThe sensing bulb is empty of liquid refrigerant charge at the designed operating temperatureDThe sensing bulb is never emptied of liquid refrigerant under normal operating conditions

单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().Achange the expansion valve adjustmentBreadjust the water regulating valve to increase the flow of waterCpurge air from the condenserDclean the waterside of the condenser

单选题The principal purpose of sub-cooling liquid refrigerant prior to its entering the expansion valve is to ().Aincrease the refrigerating effect, by decreasing the amount of flash gasBallow the refrigerant to enter the throttling device in a saturated conditionCincrease the refrigerating effect by increasing the amount of flash gasDminimize the temperature drop of the liquid as it passes through the solenoid valve to the outlet side

单选题A feeler or thermal bulb is used for the expansion valve to ().Adetect the temperatureBdetect the pressureCheat the refrigerantDaccelerate the refrigerant

单选题One function of the thermal expansion valve is to()Aact as a pilot from the solenoid valveBregulate the amount of refrigerant flow to the coilCregulate the water flowDturn the compressor off and on