单选题The thermal expansion valve reacts directly to the ()Atemperature in the space being cooledBliquid refrigerant pressure at the solenoid valveCpressure drop across the evaporator coilsDrefrigerant gas superheat at the coil outlet

单选题
The thermal expansion valve reacts directly to the ()
A

temperature in the space being cooled

B

liquid refrigerant pressure at the solenoid valve

C

pressure drop across the evaporator coils

D

refrigerant gas superheat at the coil outlet


参考解析

解析: 暂无解析

相关考题:

A thermostatic expansion valve is properly controlling evaporator superheat. Adjusting this valve to lower the superheat will result in a/anA.evaporator pressure decreaseB.evaporator coil over-feedC.evaporator capacity increaseD.expansion valve diaphragm rupture

单选题The thermal expansion valve controls the amount of refrigerant that is allowed to flow to the ().AcompressorBcooling coilsCcondenserDreceiver

单选题If a refrigeration system compressor crankcase is sweating, you should ().Aadd refrigerant to the systemBadjust the thermal expansion valve to the proper settingCadjust the float valve to the proper holding pressureDopen the hand expansion valve

单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().AopenBcloseCremain in its positionDflood the evaporator with refrigerant

单选题Aluminum pistons have () coefficient of thermal expansion compared with those of cast iron.AhigherBlowerCthe sameDnone of the above

单选题Which of the problems listed represents the major difficulty encountered with thermal expansion valve operation?()ALube oil passing through the systemBMoisture or foreign matter collecting at the valve seat and orificeCVariable spring tension caused by the changing temperatureDFrost on the liquid line

单选题The scale trap is located between the ()Aking valve and the expansion valveBsolenoid valve and expansion valveCevaporator and receiverDcompressor and evaporator

单选题What is the function of thermostatic expansion valve in a compression refrigeration system?()AnonexistentBfor controlling pressureCfor controlling superheatDfor controlling the solenoid valve

单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().Aalways be wide open when the compressor restartsBcontinue to operate as if the system were in operationCremain open until evaporator pressure equalizes, then close until the compressor restartsDalways be completely closed until the compressor restarts

单选题The bulb for the thermal expansion valve is located()Ain the middle of evaporator coilsBnear the evaporator coil outletCnear the evaporator coil inletDon the bottom row of evaporator coils

单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()AThe liquid receiver functions to collect and remove non-condensable gasesBA thermostatic expansion valve is used to control refrigerated space temperatureCRefrigerant temperature in an evaporator is directly related to refrigerant pressureDDehydrators must be used continuously in a refrigeration system

单选题What separate the high pressure side from the low pressure side in a refrigeration system?()ACondenser and thermal expansion valveBKing and solenoid valvesCCompressor and thermal expansion valveDCondenser and solenoid valve

单选题A thermostatic expansion valve is properly controlling evaporator superheatAdjusting this valve to lower the superheat will result in a/an ().Aevaporator pressure decreaseBevaporator coil over-feedCevaporator capacity increaseDexpansion valve diaphragm rupture

单选题() pistons have low inertia and high coefficient of thermal expansion.ACast ironBCast steelCForged steelDAluminum

单选题When the heat load begins to increase, the needle valve of an expansion valve will()Amove in an opening directionBmove in a closing directionCeither open or closeDnot move at all

单选题A solenoid valve used in a refrigeration system should be installed ().Awith the axis of the solenoid horizontal, sensing temperature of the box, and upstream of the thermal expansion valveBupright, sensing temperature of the box, and upstream of the thermal expansion valveCupright, sensing temperature of the box, and downstream of the thermal expansion valveDupright, sensing heat of the tail coil, and upstream of the thermal expansion valve

单选题A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().Areturn to a neutral positionBflood the evaporatorCopenDclose

单选题If the thermal bulb of an expansion valve is incorrectly placed at the center of the coil instead of the end, it will ().Aincrease the capacity of the coilBincrease the superheat at the bulbCdeliver more refrigerant to the coilDdecrease the capacity of the coil

单选题When the refrigeration demand is small,()Athe expansion valve will move toward the wide open positionBthe expansion valve will move toward the closing positionCthe feeler bulb will conveys the high temperatureDthe superheat degree will raise

单选题After passing through the expansion valve the refrigerant should be in the state of ().AvaporBliquidCsolidDNone of the above is tree

单选题A feeler or thermal bulb is used for the expansion valve to ().Adetect the temperatureBdetect the pressureCheat the refrigerantDaccelerate the refrigerant

单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().Are-adjust the discharge pressureBclean the expansion valve screenCadd refrigerantDadjust the expansion valve

单选题The low pressure side of a refrigeration system is considered to exist from the ().Aexpansion valve to the compressorBreceiver to the expansion coilCexpansion valve to the evaporatorDcondenser to the expansion valve

单选题The thermal expansion valve responds to the()Aamount of superheat in the vapor leaving the coilBamount of superheat in the liquidCtemperature in the evaporator coilsDpressure in the evaporator coils

单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()AThe condenser and the expansion valveBThe king valve and the solenoid valveCThe compressor and the expansion valveDThe condenser and the solenoid valve

单选题A pressure drop in the liquid line of a refrigeration system may cause()Athe solenoid valve to seizeBthe compressor to huntCflash gas to form in the liquid lineDthe expansion valve to freeze open

单选题One function of the thermal expansion valve is to()Aact as a pilot from the solenoid valveBregulate the amount of refrigerant flow to the coilCregulate the water flowDturn the compressor off and on